Everything in RackTrace sits in one hierarchy, from the tenant down to the single port. Knowing it makes everything else easier.

## From tenant to port

Everything sits in one hierarchy. Each level has a short ID, so every port has its own path, such as `HQ/28/SL/RK001/C/01`.

![A site page with its floors and rooms](https://docs.racktrace.io/assets/screens/site.webp "A site with its floors and the rooms on each floor.")

| Level | What it is | Example ID |
|---|---|---|
| Tenant | A fully separate environment: your own organisation, or one customer. | — |
| Site | A building or location. | `HQ` |
| Floor | A floor of the site. | `00`, `28` |
| Room | Server room, telecom room, office area … | `SL` |
| Rack | A rack with a height in U. Devices are placed by their bottom U. | `RK001` |
| Device | A switch, patch panel, server, floor box, access point, PC … in a rack or directly in a room. | `SW01` |
| Port | A front or rear port of a device. | `01` |

How ports and cables work, from patch panels to trunks, is explained in [Ports, cables and trunks](https://docs.racktrace.io/concepts/ports-and-cables). A tenant with two separate environments uses [networks](https://docs.racktrace.io/concepts/networks).

What you may change depends on your role and groups. Pages hide what you cannot do. See [Roles and rights](https://docs.racktrace.io/administration/users-and-groups#roles).

## Example: the path of a port

The path `HQ/00/SL/RK001/PP01/01` reads as:

| Part | Level | Meaning |
|---|---|---|
| `HQ` | Site | Headquarters |
| `00` | Floor | Ground floor |
| `SL` | Room | Server room |
| `RK001` | Rack | Main rack |
| `PP01` | Device | A patch panel |
| `01` | Port | Port 01 of the panel |

A device that is not in a rack has no rack in its path: a floor box in the office is `HQ/00/LA/FB01`, and its first port `HQ/00/LA/FB01/01`.

## IDs and paths

- An ID may contain letters, digits and `. _ - + #`, at most 32 characters, with no spaces or slashes.
- IDs must be unique within their parent, ignoring upper and lower case: two racks in one room can't both be `RK001`, but two rooms can each have one.
- Leave the ID empty and RackTrace makes one from the name: the initials of several words (*Server Room* → `SR`, *Floor 28* → `F28`), or the word in capitals. If it's taken, `-2`, `-3` … is added.
- A device without ID and name gets its category prefix and a number: `SW01`, `PP01`, `FB01`, `AP01`, `SRV01` …