# RackTrace documentation > RackTrace documents networks and racks, from the building down to the single port: sites, floors, rooms, racks, devices, ports, cables, VLANs and IP addresses, with UniFi, Domotz and other integrations. These are the user docs of the RackTrace web app, in English. ## Getting started > RackTrace documents your network and racks from the building down to the single port. Start here. URL: https://docs.racktrace.io/ RackTrace documents your network and your racks, from the building down to the single port: where every device sits, which cable goes where, and how the network is set up. These docs explain every part of the app, step by step. ![The dashboard of a tenant with its sites, racks, devices and cables](https://docs.racktrace.io/assets/screens/dashboard.webp "The dashboard of a tenant: its sites, racks, devices and cables at a glance.") ### Where to start - [Quickstart](https://docs.racktrace.io/quickstart): Your first rack in ten steps, from an empty tenant to a traced cable. - [Signing in](https://docs.racktrace.io/signing-in): E-mail address and password, passkey or Microsoft, and the second step. - [Locations, IDs and paths](https://docs.racktrace.io/concepts/structure): How RackTrace is organised, from tenant to port. - [Troubleshooting](https://docs.racktrace.io/troubleshooting): Messages you may meet, and what to do about them. ### Everything in RackTrace - [Rack editor](https://docs.racktrace.io/features/rack-editor): Place devices and patch cables between ports. - [Floor plans](https://docs.racktrace.io/features/floor-plans): Drawings, outlets, access points and cable lengths. - [Cables and tracing](https://docs.racktrace.io/features/cables-and-tracing): Follow a cable from the switch to the desk. - [Labels and QR codes](https://docs.racktrace.io/features/labels): Cable, outlet and patch panel labels. - [Network plan](https://docs.racktrace.io/network/network-plan): VLANs, port profiles and the route check. - [Discovery](https://docs.racktrace.io/integrations/discovery): Compare the documentation with UniFi and other sources. - [Network monitoring](https://docs.racktrace.io/network/monitoring): Every network device from discovery monitored, on one screen with a live map. - [Network simulation](https://docs.racktrace.io/network/simulation): Test a change before you make it: VLANs, routing, firewall, failures and traffic. - [Administration](https://docs.racktrace.io/administration/users-and-groups): Users, groups, sign-in and backups. ### How these docs work - The names of buttons, fields and menus are written in **bold**, exactly as they appear on screen. - Search with the box at the top, or press `Ctrl`+`K` (`⌘`+`K` on a Mac) or `/`. - What you may do depends on your role. Buttons you cannot use are not shown; see [Roles and rights](https://docs.racktrace.io/administration/users-and-groups#roles). - The docs are in English and Dutch: switch at the top right. --- ## Quickstart > Your first rack in ten steps, from an empty tenant to a cable traced from the PC to the switch. URL: https://docs.racktrace.io/quickstart This guide takes you from an empty tenant to a complete, traced cable: a switch and a patch panel in a rack, a floor box in an office, and a PC plugged in. Do the steps in order; each takes a minute. > **Good to know** > > Just want to look around first? An administrator can load a fully cabled example with **Load demo tenant** under **Administration → Tenants**. You can delete it afterwards. ### 1. Choose the tenant Sign in (see [Signing in](https://docs.racktrace.io/signing-in)) and pick the tenant you want to work in with the **Tenant** picker at the top. A tenant is one customer, or your own organisation. No tenant yet? An administrator creates one under **Administration → Tenants** with **New tenant**. ### 2. Create a site 1. On the dashboard, click **New site**. 2. Fill in **ID** `HQ` and **Name** `Headquarters`, and click **Create site**. The ID is short on purpose: it becomes the start of every path, such as `HQ/00/SL/RK001`. See [IDs and paths](https://docs.racktrace.io/concepts/structure#ids). ### 3. Add a floor On the site page, click **New floor**, fill in **ID** `00` and **Name** `Ground floor`, and click **Create floor**. ### 4. Add a server room and an office 1. On the site page, click **Room** in the block of floor 00. 2. Create the server room: **ID** `SL`, **Name** `Server room`. 3. Click **Room** once more and create the office: **ID** `LA`, **Name** `Office area`. ### 5. Add a rack Open the server room and click **New rack**. Fill in **ID** `RK001`, **Name** `Main rack` and **Height (U)** `42`, and click **Create rack**. ### 6. Fill the rack Click the rack to open it in the [rack editor](https://docs.racktrace.io/features/rack-editor). 1. In the **Devices** panel on the left, choose **Generic** in the list of manufacturers. 2. Drag **Patch Panel 24x RJ45 Cat6** onto the top rack unit. 3. Drag **Switch 24x GbE + 4x SFP+** onto the unit below it. Each device gets an ID straight away (such as `PP01` and `SW01`), and the cursor jumps to its **Name** field, so you can type a name. Everything is saved as you go. ![The rack editor with a patch panel and a switch](https://docs.racktrace.io/assets/screens/rack-editor.webp "The rack editor: the device templates on the left, the rack in the middle, the inspector on the right.") ### 7. Add a floor box in the office Open the office (room `LA`) and click **Add device**. Choose the **Template** **Floor Box 2x RJ45**, leave **ID** empty for an automatic one, and click **Add device**. ### 8. Cable the floor box to the patch panel This is the permanent cabling in the building: from the rear of the patch panel to the floor box. 1. Go back to the rack editor and click the patch panel. 2. In the inspector, choose **Tools → Manage building connections**. 3. Set **Number of connections** to `2` and choose the **Target room** `LA`. The floor box is ticked under **Target devices**. 4. Check the **Preview** and click **Create connections**. ### 9. Patch the panel to the switch In the rack editor, click port 01 of the patch panel and then port 01 of the switch. A patch cable appears between them, in its colour. To connect a whole range at once, use **Tools → Bulk connect…** (see [Bulk connect](https://docs.racktrace.io/features/cables-and-tracing#bulk-connect)). ### 10. Connect a PC and trace the cable 1. In the office, click **Add device**, choose the **Template** **Workstation** and click **Add device**. 2. On the device page of the PC, click its port and then **Connect cable**. Choose the floor box, then port 01, and click **Connect**. 3. Click **Trace** on the same port. The trace shows the whole path: from the PC, through the floor box and the patch panel, to the switch. See [Tracing a cable end to end](https://docs.racktrace.io/features/cables-and-tracing#tracing). ![A trace from a PC through a floor box and a patch panel to the switch](https://docs.racktrace.io/assets/screens/trace.webp "A trace follows the cable through every patch panel and outlet on the way.") ### Next steps - Put the drawing of the floor in RackTrace and place the rack and the floor box on it: [Floor plans](https://docs.racktrace.io/features/floor-plans). - Print cable labels and a QR sticker for the rack: [Labels and QR codes](https://docs.racktrace.io/features/labels). - Document the VLANs and give the switch ports a profile: [Network plan](https://docs.racktrace.io/network/network-plan). - Invite your colleagues: [Users, groups and rights](https://docs.racktrace.io/administration/users-and-groups). --- ## Signing in > Sign in with your e-mail address and password, a passkey or your Microsoft work account, and confirm the second step. URL: https://docs.racktrace.io/signing-in You sign in with your e-mail address. Depending on how your organisation is set up, you use a password, a passkey or your Microsoft work account, and sometimes a second step. ### Signing in with your e-mail address You don't need to know the address of your organisation: sign in on `app.racktrace.io` and RackTrace takes you there. 1. Go to `app.racktrace.io`, or go to [racktrace.io](https://racktrace.io/), click **Sign in** and then **Sign in with your e-mail address**. 2. Enter your **E-mail address** and **Password**. 3. Leave **Keep me signed in** ticked to stay signed in for 30 days (renewed while you use RackTrace). Without it you are signed out after 12 hours without activity, or when you close the browser. 4. Click **Sign in**. You land in your organisation. Does your e-mail address have an account in more than one organisation? Then **Choose your organization** lists them: click the one you want. If your account has two-step verification, the [second step](https://docs.racktrace.io/signing-in#two-step) follows on your organisation's page. Every organisation also has its own address, such as `yourcompany.racktrace.io`, or its own domain, such as `docs.yourcompany.com`. You can sign in there directly as well, with the same e-mail address and password; the eye button shows or hides what you typed. ![The sign-in page of an organisation](https://docs.racktrace.io/assets/screens/sign-in.webp "The sign-in page of your organisation, with the e-mail address, the password and Sign in with a passkey.") **Sign in with a passkey** (below the password form) signs you in with your fingerprint, face or device PIN, without an e-mail address or password. Your browser may also offer the passkey when you click the E-mail address field. A passkey belongs to your organisation's own address: on `app.racktrace.io`, click **Sign in with Microsoft or a passkey**, type the first part of the address in **Organization** and click **Continue**. You first need to add a passkey under [My account](https://docs.racktrace.io/account/my-account#passkeys). **Sign in with Microsoft** appears when your organisation has set it up. Click it and sign in with your work account (Microsoft 365). Microsoft checks your password and the second step, so RackTrace doesn't ask for its own. When your organisation requires Microsoft, only that button is shown; the password form under **Administrator? Sign in with your password** is for administrators, for when Microsoft is not available. Signing in with a password on `app.racktrace.io` then shows a link to the organisation's own address (**Go to …**). > **Forgot your password?** > > There is no reset link. Ask an administrator to set a temporary password; you choose your own the next time you sign in. After a session ends, signing in again brings you back to the page you were on, also when you came from a QR label. ### Creating your account from an invitation When an administrator adds you, you get the e-mail *You are invited to … in RackTrace*. It tells you your role, which tenants you can open, and what is expected of you. 1. Click **Create your account** in the e-mail. The page shows your e-mail address: you sign in with it. 2. Check **Your name**, fill in a password of at least 8 characters under **Choose a password** and **Repeat the password**, and click **Create account**. When your organisation uses Microsoft, you can click **Sign in with Microsoft** instead; when it requires Microsoft, that is the only button. 3. You are signed in. If your organisation requires two-step verification, you [set it up](https://docs.racktrace.io/signing-in#two-step) straight away. The link works once and is valid for 7 days. Has it expired, or does it say *This invitation no longer works*? Ask the administrator who invited you to send it again: just reply to the e-mail. After your first sign-in you get a second e-mail with a short explanation of how RackTrace works and links to these docs. ### An account with a username from before Accounts made before RackTrace used e-mail addresses still have a username, such as `admin`. Sign in with it once on your organisation's address; RackTrace then shows **Add your e-mail address**. 1. Type your work e-mail address in **E-mail address** and **Repeat e-mail address** and click **Save and continue**. If you signed in more than 15 minutes ago, RackTrace also asks for your password. 2. RackTrace sends a link to that address and shows **Check your mailbox**. Open the e-mail *Confirm your e-mail address* — on your computer or your phone — and click **Confirm e-mail address**. 3. The page you signed in on continues by itself. From then on you sign in with that address; your password, passkeys and two-step verification stay the same. The link works once and for 24 hours. Nothing arrived? Look in your spam folder or click **Send the link again**; a typing error is fixed with **Use another address**. Don't have a work e-mail address, or does someone else already use it? Ask an administrator: they can enter the address for you under [Users](https://docs.racktrace.io/administration/users-and-groups#users). ### The second step With two-step verification on, RackTrace asks for more than your password on the **Two-step verification** screen (when you signed in on `app.racktrace.io`, it opens on your organisation's own address): - **App code**: open your authenticator app and type the 6-digit code for RackTrace. It is sent by itself after the sixth digit (or click **Verify**). - **Passkey**: the browser asks for your fingerprint, face or PIN straight away. Click **Use my passkey** to try again. - **Recovery code**: one of the codes you saved when you set up two-step verification, like `abcd-efgh`. Each code works once. Switch between them with **Use a passkey**, **Use the code from my app** and **Use a recovery code**. **← Back** returns to the password. Finish the second step within 5 minutes; after 5 wrong codes you start again with your password. If your administrator requires two-step verification and you haven't set it up, you see **Set up two-step verification** right after signing in. Choose **Passkey** (recommended) or **Authenticator app** and follow the steps in [Passkeys](https://docs.racktrace.io/account/my-account#passkeys) or [Authenticator app](https://docs.racktrace.io/account/my-account#auth-app). If you signed in more than 15 minutes ago (your administrator made two-step verification required while you were signed in), RackTrace also asks for your password. If your password was set by an administrator, you first see **Choose a new password**: enter the temporary password, then your new one twice, and click **Save and continue**. --- ## Locations, IDs and paths > How RackTrace is organised from tenant to port, how every port gets its own path, and the rules for IDs. URL: https://docs.racktrace.io/concepts/structure Everything in RackTrace sits in one hierarchy, from the tenant down to the single port. Knowing it makes everything else easier. ### From tenant to port Everything sits in one hierarchy. Each level has a short ID, so every port has its own path, such as `HQ/28/SL/RK001/C/01`. ![A site page with its floors and rooms](https://docs.racktrace.io/assets/screens/site.webp "A site with its floors and the rooms on each floor.") | Level | What it is | Example ID | |---|---|---| | Tenant | A fully separate environment: your own organisation, or one customer. | — | | Site | A building or location. | `HQ` | | Floor | A floor of the site. | `00`, `28` | | Room | Server room, telecom room, office area … | `SL` | | Rack | A rack with a height in U. Devices are placed by their bottom U. | `RK001` | | Device | A switch, patch panel, server, floor box, access point, PC … in a rack or directly in a room. | `SW01` | | Port | A front or rear port of a device. | `01` | How ports and cables work, from patch panels to trunks, is explained in [Ports, cables and trunks](https://docs.racktrace.io/concepts/ports-and-cables). A tenant with two separate environments uses [networks](https://docs.racktrace.io/concepts/networks). What you may change depends on your role and groups. Pages hide what you cannot do. See [Roles and rights](https://docs.racktrace.io/administration/users-and-groups#roles). ### Example: the path of a port The path `HQ/00/SL/RK001/PP01/01` reads as: | Part | Level | Meaning | |---|---|---| | `HQ` | Site | Headquarters | | `00` | Floor | Ground floor | | `SL` | Room | Server room | | `RK001` | Rack | Main rack | | `PP01` | Device | A patch panel | | `01` | Port | Port 01 of the panel | A device that is not in a rack has no rack in its path: a floor box in the office is `HQ/00/LA/FB01`, and its first port `HQ/00/LA/FB01/01`. ### IDs and paths - An ID may contain letters, digits and `. _ - + #`, at most 32 characters, with no spaces or slashes. - IDs must be unique within their parent, ignoring upper and lower case: two racks in one room can't both be `RK001`, but two rooms can each have one. - Leave the ID empty and RackTrace makes one from the name: the initials of several words (*Server Room* → `SR`, *Floor 28* → `F28`), or the word in capitals. If it's taken, `-2`, `-3` … is added. - A device without ID and name gets its category prefix and a number: `SW01`, `PP01`, `FB01`, `AP01`, `SRV01` … --- ## The user interface > The top bar, the side menu, the location tree, the bars at the top of the page and the tenant dashboard. URL: https://docs.racktrace.io/concepts/user-interface RackTrace looks the same on every page: a top bar, a side menu with the location tree, and the page itself. ![RackTrace with the top bar, the side menu and a tenant dashboard](https://docs.racktrace.io/assets/screens/dashboard.webp "The top bar with the tenant picker and the search, the side menu with the location tree, and the dashboard of a tenant.") ### Finding your way around #### The top bar - **Tenant** picker: switches between the customers or environments you have access to and opens that tenant's dashboard. - **Search** (*Search devices, IPs, serials, cables…*): searches all your tenants. See [Search](https://docs.racktrace.io/features/history-and-search#search). - Coloured initials: colleagues who are on the same page right now. See [Working together live](https://docs.racktrace.io/concepts/working-together#presence). - Your name: the user menu with **My account**, **Change password**, **Toggle dark mode**, **What's new** (what the latest RackTrace updates brought), **Help & docs** (these docs, in a new tab) and **Sign out**. It also shows the RackTrace version. #### The side menu - **Dashboard** of the selected tenant. - **Network**: **Network plan**, **Discovery**, **Domotz** (once Domotz is connected) and **Simulation**. - **Library & reports**: **Device library**, **History**, **Labels** and **Export & reports**. - **Administration** (administrators only): **Tenants**, **Users**, **Groups**, **Login & security**, **Integrations** and **System status**. - **Locations**: the tree of sites, floors, rooms and racks of the tenant. Click the arrows to fold a level open; click a name to open it. The **+** next to **Locations** creates a new site. Click a group name to fold it away; your browser remembers this. On a phone, the menu is behind the menu button at the top left. #### Bars at the top of the page - A bar about an incident or maintenance comes from the RackTrace status page. **Status page** opens the details; the × hides the bar until the notice changes. - After an update, a purple bar **New in RackTrace** shows what changed. **See what's new** opens the list of changes; once you opened it or closed the bar with the ×, it does not come back — also not on another computer. You can read it again under **What's new** in the user menu. - Administrators see a warning bar when a check on [System status](https://docs.racktrace.io/administration/system-status#system-status) fails. ### The tenant dashboard The dashboard opens when you choose a tenant. It shows: - Totals for **Sites**, **Racks** (with how many U are used), **Devices** (and how many are planned) and **Cables** (with how many ports are connected). - **Sites**: a tile per site with its floors, rooms, racks and devices. Click a tile to open the site. - **Recent changes**, with **View all** for the full [history](https://docs.racktrace.io/features/history-and-search#history). - The **Networks** card (see [Networks](https://docs.racktrace.io/concepts/networks#networks)) and **Devices by category**. - A banner when there are open [security alerts](https://docs.racktrace.io/network/unifi-review#alerts). Click it to check them. --- ## Ports, cables and trunks > Front and rear ports, pass-through ports, cables, trunks, PATCHBOX cassettes and planned cables. URL: https://docs.racktrace.io/concepts/ports-and-cables A cable always connects two ports. Some devices pass a connection through from the front to the rear, so a trace can follow a cable from the switch all the way to the desk. ### Ports Every device has ports: on the front, on the rear, or both. A template from the [device library](https://docs.racktrace.io/features/device-library) brings the real ports with it, with their names, types (RJ45, SFP, fibre, power …), speed and PoE. You can rename a port with a **Label**, and add ports to a device yourself; see [Editing a port](https://docs.racktrace.io/features/devices#port-dialog). ### Cables - A **cable** connects exactly two ports, and each port can have one cable. - A cable has a label (such as `C-0042`, made automatically), a type, a colour and optionally a length. - A cable between two devices in a rack is a patch cable; a cable from a patch panel to a floor box in another room is part of the permanent cabling of the building. RackTrace treats both the same way, so a [trace](https://docs.racktrace.io/features/cables-and-tracing#tracing) can follow both. ### Pass-through ports Patch panels, floor boxes, wall outlets and fibre panels have **pass-through** ports: a front port and a rear port that are connected inside the device. The building cabling arrives at the rear; you patch at the front. A trace runs through them: from the switch, through the patch cable to the front of the panel, from its rear through the building cable to the floor box, and from the floor box to the PC. In the rack editor and on the device page, the rear of a pass-through port is marked **(R)** or **rear**. Both ends of a pass-through port have the same name, 01 … 24 from the template. Give a patch panel your own numbering, such as A-01 … A-24, when you add it or later; see [Port numbering](https://docs.racktrace.io/features/rack-editor#port-numbering). ### Trunks A **trunk** is a named bundle of cables between two racks, such as 24× Cat6a between two patch panels. Each cable in it keeps its own label and can still be traced and changed on its own. See [Trunks between racks](https://docs.racktrace.io/features/row-view-and-trunks#trunks). ### PATCHBOX cassettes A PATCHBOX has cassettes instead of fixed ports: each cassette is a retractable patch cable with a top end ↑ and a bottom end ↓, such as `PBX01/5↑`. A trace runs through a cassette like through a patch panel. See [PATCHBOX cassettes](https://docs.racktrace.io/features/rack-editor#patchbox). ### Cable types, colours and planned cables - **Types**: Cat5e, Cat6, Cat6a, Cat7, Cat8, Fiber OM3, Fiber OM4, Fiber OS2, DAC, AOC, Coax, Power, Console and Other. - **Colours**: blue, yellow, green, red, orange, purple, grey, white, black, aqua, pink and brown. The colour is drawn in the rack editor and on the trace. - **Length**: used for the total length of a trace and on the floor plan; the simulation uses the type and length to work out what the copper allows. - **Planned**: tick **Planned — not installed yet** in the rack editor's cable dialog, or on a trunk. Planned cables are dashed, so you can document the next situation next to today's. Domotz doesn't expect to see them, the [cabling check](https://docs.racktrace.io/integrations/discovery#cabling-check) tells you when a planned cable is already live, and the simulation can include them. --- ## Networks > Keep two environments, such as an office network and a production network, apart within one tenant. URL: https://docs.racktrace.io/concepts/networks Most tenants have one network. When a customer runs two separate environments at one location, networks keep them apart. ### Networks (IT, PRD …) Use networks when one tenant has more than one environment, such as an office network (IT) and a production network (PRD). Devices, trunks, VLANs and port profiles get a coloured network label, and a VLAN ID only has to be unique per network: VLAN 10 can exist in IT and in PRD. 1. On the **VLANs & profiles** tab (or the dashboard), click **New network** in the **Networks** card. 2. Fill in the **Short name** (e.g. PRD), **Description**, **Colour** and **Order**. 3. Click **Save**. Give devices, trunks, VLANs and profiles their **Network** in their own forms. In [Integrations](https://docs.racktrace.io/integrations/unifi#unifi-setup), every UniFi site, JSON scope and Domotz collector can report on one network; **+ New network…** creates one on the spot. Deleting a network only removes the label. It is refused when it would leave two VLANs with the same ID, or two profiles with the same name, without a network. --- ## Source and freshness > What documented, observed, planned and simulated mean in RackTrace, how old a source's data may be, and why unknown is not down. URL: https://docs.racktrace.io/concepts/source-and-freshness RackTrace keeps four kinds of knowledge apart, and every observation says where it comes from and how old it is. So you can always tell what someone entered, what a source saw, what is still to be built and what the simulation computed. ### The four states | Label | What it means | |---|---| | **Documented** | Entered in RackTrace: by a person, an import, or a discovery sync you reviewed. This is the documentation. | | **Observed** | Reported by a discovery source (UniFi, Meraki, FortiGate, the scanner, a JSON source, Auvik), with the source and the age of its last report: **Observed 12 min ago · UniFi**. | | **Planned** | Intended, not built yet — a planned cable, for example. | | **Simulated** | Computed by the [simulation](https://docs.racktrace.io/network/simulation) from the documentation and the sources: decision support, not a measurement. | You find the labels at the top of a device page (**Documented** and one **Observed** label per discovery source of the device), next to a planned cable in its ports, in the sources strip on the **Discovery** page, in **All tenants** and above a simulation result. Hover over an **Observed** label to see the source, when the source observed it, when RackTrace received it and when it counts as old. ### Fresh, old and unknown An observation is one of three: - **Fresh** (green) — the source's last report is younger than the threshold of its kind. - **Old** (amber, striped: **Observed 7 h ago — old**) — the report is older than the threshold. It says what was true then, not now: a port it reported down gets a dashed ring and counts as unknown, and the online or offline dot of the device turns grey. **All tenants** lists the source as a notice. - **Unknown** (grey: **Not observed yet**) — the source never reported anything. That is not old (there is no data to be old) and not down or off. > **Unknown is not down** > > A silent scanner, a source that never synced, a wrong configuration and a device that has failed stay different things. Only a fresh report that a link or device is down counts as down. ### Thresholds per kind of source | Kind of source | Sources | Old after | |---|---|---| | Controller API | UniFi (Site Manager), Meraki (Dashboard API), FortiGate (REST API), NetBird | 6 hours | | Scanner (SNMP) | The RackTrace agent | 6 hours | | JSON push | A script or system that pushes the open JSON format | 6 hours | | Import from another system | Auvik, JSON pull (URL) | 6 hours | | Monitoring check | Every check | 3 of its intervals (each at least a minute): then the check is **unknown** | The same threshold applies everywhere: on the device page, in the simulation and in **All tenants** one source is fresh or old in all three. A source with a longer refresh interval (up to 1440 minutes) than its threshold, or one that is only read by hand (interval 0), shows as **old** between two syncs. That is how old its data really is; the threshold stays that of its kind. The tooltip of the label shows the refresh interval next to the threshold. ### Observation time and receipt time Every report has two times: when the source **observed** it and when RackTrace **received** it. A pull source (UniFi, Meraki, FortiGate, Auvik, a JSON URL) observes at the start of the read. A push (the scanner, a JSON push) may send its own time: `observed_at` per scope or for the whole push, or the start time of a scan. The observation time counts for the freshness, as long as it is no more than 5 minutes after the receipt and no more than 24 hours before it — the same window as for monitoring measurements. A JSON push with a time outside that window is refused with a message that says why (check the clock of the sender); a scan whose start time is outside it gets a note on the source and counts from its receipt, as does a push without a time. So a report observed 10 minutes ago and received now is **10 min** old, and the tooltip shows both times. --- ## Working together live > See who else is on a page, and how changes made by colleagues appear on yours. URL: https://docs.racktrace.io/concepts/working-together What a colleague changes appears on your page by itself, like a shared spreadsheet. The page is brought up to date without reloading it. ### Who else is here Coloured initials in the top bar show the colleagues on the same page. When nobody is on your page but others are online, you see how many are online. Click them for **Online now**: who is **On this page** and who is **Elsewhere**, with the page they are on; click a name to go there. ### Changes from colleagues - A message says who did what, such as *Jan changed device HQ/00/SL/RK001/SW01*. Changed devices, cables, rows and tiles light up for a moment. - Your scroll position, the rack editor's zoom, selection and undo, and the floor plan's zoom and pan all stay as they are. - While you are busy (a dialog open, typing, dragging, a cable half connected), the update waits. A bar says so; **Update now** applies it at once. - New sites, rooms and racks appear in the location tree. You only hear about tenants you may see. --- ## Keyboard shortcuts > Every keyboard shortcut and mouse control of the rack editor and the floor plan. URL: https://docs.racktrace.io/concepts/shortcuts The rack editor and the floor plan have keyboard shortcuts for the things you do most. On a Mac, use `⌘` instead of `Ctrl`. ### At a glance | Key | Rack editor | Floor plan | |---|---|---| | `Ctrl`+`Z` | Undo | Undo | | `Ctrl`+`Y` | Redo | Redo | | `+` / `−` | Zoom | Zoom | | `R` | Front / back | Room tool, or turn the selected rack | | `←` / `→` | Previous / next rack of the room | — | | `V` / `P` / `M` | — | Select / Shape / Scale tool | | `F` | — | Show the whole floor | | `Delete` | Delete the selected device | Take the selected item off the plan | | `Esc` | Cancel, or clear the selection | Cancel the tool, or clear the selection | | `/` or `Ctrl`+`K` | In these docs: search | ### Rack editor | Key or mouse | Action | |---|---| | `Ctrl`+`Z` | Undo | | `Ctrl`+`Y` or `Ctrl`+`Shift`+`Z` | Redo | | `R` | Switch front / back | | `+` / `−` | Zoom in / out | | `Ctrl` + scroll wheel | Zoom around the pointer (pinch on a touchpad) | | Right or middle mouse button + drag | Move around the racks; let go while moving and it glides on | | Right mouse button + drag past the left or right edge | Open the previous or next rack of the room (let go when the tab says *Release to open*) | | `←` / `→` | Previous / next rack of the room (in the row view: move the row to it) | | `Delete` | Delete the selected device | | `Esc` | Cancel connecting or placing, or clear the selection | On a Mac, use `⌘` instead of `Ctrl`. Shortcuts don't work while a dialog is open or while you are typing in a field. ### Floor plan | Key or mouse | Action | |---|---| | `V` / `R` / `P` / `M` | Select / Room / Shape / Scale tool (`R` turns a selected rack instead) | | `D` | Find the rooms in the drawing | | `Ctrl`+`Z`, `Ctrl`+`Y` | Undo, redo (everything on the plan except uploading or removing the drawing) | | Scroll wheel | Zoom (`Ctrl` + scroll zooms faster) | | `+` / `−` | Zoom in / out | | `F` | Show the whole floor | | Drag the background, or right mouse button + drag | Move the plan | | `Delete` | Take the selected device or rack off the plan | | `Esc` | Cancel the tool, stop editing a shape, or clear the selection | Users who may only look can open the plan, select items, use the toggles and print. On a phone the plan is shown above the details of what you tap; tap an item in the list and then tap the plan to place it. --- ## Sites, floors and rooms > Create the structure of a tenant: sites, floors, rooms and racks, and what their pages show. URL: https://docs.racktrace.io/features/locations Build the structure first: a site, its floors, the rooms on each floor and the racks in each room. Devices and cables come after that. ### Creating sites, floors, rooms and racks 1. **Site**: click **New site** on the dashboard, or the **+** next to **Locations** in the side menu. Fill in **ID** (e.g. HQ), **Name**, **Address** and **Notes**, then click **Create site**. 2. **Floor**: on the site page, click **New floor**. Give an **ID** (e.g. 00 for the ground floor) and/or a **Name**. **Sort order** decides the order in lists: lower numbers come first. 3. **Room**: on the site page, click **Room** in the block of a floor, or **New room** on the floor page. Fill in **ID** (e.g. SL), **Name** and optionally **Building / wing**. 4. **Rack**: on the room page, click **New rack**. Fill in **ID** (e.g. RK001), **Name**, the **Cabinet model** (optional: the real cabinet, which also sets the height — see [Rack cabinets](https://docs.racktrace.io/features/rack-cabinets#cabinet-model)), **Height (U)** (42 by default), **Position in room** (the order from left to right in the [row view](https://docs.racktrace.io/features/row-view-and-trunks#row-view)) and **Asset tag**. After each step the new page opens, so you can go straight on to the next level. ### Site, floor and room pages - **Site page**: **Floors & rooms** with a block per floor, each with a **Floor plan** button and tiles for its rooms. At the top: **Report** (a [printable report](https://docs.racktrace.io/features/export#report) of this site), **Labels**, **Edit**, delete and **New floor**. - **Floor page**: a small picture of the [floor plan](https://docs.racktrace.io/features/floor-plans) (click it to open the plan) and the **Rooms** of the floor. **Report** prints this floor; **Share** makes a [read-only link](https://docs.racktrace.io/features/share-links) to it for someone without an account. - **Room page**: - **Racks**: a small drawing per rack. Click one to open it in the [rack editor](https://docs.racktrace.io/features/rack-editor). **Import from a drawing** brings in racks and cabling from draw.io, Visio or Lucidchart (see [Importing from a drawing](https://docs.racktrace.io/features/import-drawings)). - **Links between racks**: the cables and trunks between the racks of the room. - **Devices outside racks**: floor boxes, wall outlets, access points, desks and other endpoints in the room. - Buttons: **Row view** (when the room has more than one rack), **Floor plan**, **Labels**, **Report** (its racks side by side on one sheet, and if you like the cables between them on the floor plan — see [the printable report](https://docs.racktrace.io/features/export#report)), **Share** (a [read-only link](https://docs.racktrace.io/features/share-links) for someone without an account), **Add device** and **New rack**. ![A room page with its racks and the links between them](https://docs.racktrace.io/assets/screens/room.webp "A room page: its racks, the links between them and the devices outside racks.") Every location page ends with a **History** card of the last changes there. ### Editing and deleting a location Click **Edit** on the site, floor or room page to change its fields; rack settings are changed in the rack editor's inspector. If you clear the ID while editing, the current ID is kept. > **Caution** > > **Deleting removes everything inside it.** Deleting a site also deletes all its floors, rooms, racks, devices and cables; a room deletes its racks, devices and cables. The deletion is recorded in the history but cannot be undone. Download a [full backup](https://docs.racktrace.io/features/export#export) first if you might need the data. --- ## Devices and ports > Add devices, use the device page, edit, move or change the model of a device, edit ports and fit expansion cards. URL: https://docs.racktrace.io/features/devices Devices in a rack are easiest to add in the [rack editor](https://docs.racktrace.io/features/rack-editor). Devices outside racks, such as floor boxes, wall outlets, access points and PCs, are added from the room page or straight on the [floor plan](https://docs.racktrace.io/features/floor-plans#plan-create). ### Adding a device to a room 1. Open the room page and click **Add device**. 2. Choose a **Template** from the device library. A template creates all ports with their real names, types and layout. Choose **— Custom device (no template) —** for anything that isn't in the library; you then pick the **Category** and **Height (U)** yourself and add ports afterwards. 3. Fill in **ID** (or leave it empty for an automatic one such as FB01) and **Name**. For a patch panel or outlet, **Port numbering — first port** names its ports: type `A-01` and they become A-01, A-02 … (see [Port numbering](https://docs.racktrace.io/features/rack-editor#port-numbering)). 4. Set the **Status**: Active, Planned, Offline or Decommissioned. 5. Optionally fill in **Management IP**, **MAC address**, **Serial number**, **Asset tag** and **Notes** (a patch panel, PATCHBOX or blank panel only has **Notes**). **Free IP** next to the IP field suggests the next free address of a VLAN (see [IP addresses](https://docs.racktrace.io/network/ip-addresses#ipam)). 6. Click **Add device**. The device page opens. ### The device page Open a device from the rack editor, a room page, search or a trace. The page shows: ![The device page of a switch](https://docs.racktrace.io/assets/screens/device.webp "The device page of a switch: details, connected devices, the faceplate and the port list.") - **Details**: the full path as ID, model, category, status, network, location (rack and U, or the room), whether a [front bezel](https://docs.racktrace.io/features/rack-editor#bezels) is fitted, management IP, MAC, serial, asset tag, template, the live state from **Discovery** and **Domotz** when the device is linked, and its asset in **Hudu** or configuration in **IT Glue** (see [Hudu and IT Glue](https://docs.racktrace.io/integrations/hudu-it-glue)). - **Connected devices**: every device it reaches end to end, through patch panels and outlets, with the port pairs. - **Ports**: the front and rear faceplate. Hover a port for its details; click it to open the [port dialog](https://docs.racktrace.io/features/devices#port-dialog). Patch panels, PATCHBOXes and outlets have **Port numbering** here to give all ports another name at once. - **Expansion slots** for servers, storage and other devices with slots. - **Port list**: every port with type, PoE (what it offers, and its setting), VLANs, role and link aggregation, label, cable, what it is connected to, the end-to-end result and, with discovery, a **Live** column. A port that is switched off has an **off** tag. Filter with **All**, **Connected** or **Free**; the trace icon opens the [trace](https://docs.racktrace.io/features/cables-and-tracing#tracing). - **History** of the device. Buttons at the top: **Open in rack editor**, **Open in Hudu** or **Open in IT Glue** for a linked device, **Labels**, **Floor plan**, and for editors **Edit**, **Move**, **Change model**, **Duplicate** and delete. ### Editing, moving and changing the model #### Edit **Edit** changes ID, name, status, category, network, manufacturer, model, IP, MAC, serial, asset tag, height, **Full depth (blocks front and rear)**, **Display colour** and notes. Click **Save**. #### Move to another room or rack 1. Click **Move**. 2. Under **New location**, pick a room (the device then stands outside a rack) or a rack. 3. For a rack, optionally set **Position (bottom U)** (empty = the first free slot) and **Mounted on** (Front or Back). 4. Click **Move**. Cables stay connected. #### Change model 1. Click **Change model** and search for the new model or part number. 2. Check the preview. Cables, labels, VLANs and the port settings (PoE setting, switched off, link aggregation) move to the port with the same name; RackTrace warns when connected ports don't exist on the new model, because those cables would be removed. A patch panel with its own [port numbering](https://docs.racktrace.io/features/rack-editor#port-numbering) keeps it on the new model (**Keep the port numbering …**, ticked), so its cables find their ports. 3. Click **Change model** (and confirm **Remove those cables** if asked). ID, name, IP and notes stay the same; fitted cards stay when their slot exists on the new model. ### Duplicating and deleting a device - **Duplicate** makes a copy with the same ports, without cables, in the same room or rack. The ID and name count up (SW01 → SW02). In a rack you can set the **Position (bottom U)**. IP, serial, MAC, asset tag, notes and port labels are not copied. - The delete button removes the device and its cables. On the device page this cannot be undone; in the rack editor it can (`Ctrl`+`Z`). ### Editing a port Click a port on the device page. The port dialog shows: ![The port dialog of a switch port](https://docs.racktrace.io/assets/screens/port-dialog.webp "The port dialog: what the port is connected to, end to end, and its details.") - **Connection**: what the port is connected to, the cable (label, trunk, type, length, colour) and the end-to-end result, with **Trace**, **Simulate**, **Edit cable** and **Disconnect**. A free port has **Connect cable**; see [Connecting a cable](https://docs.racktrace.io/features/cables-and-tracing#connect-cable). - **Live from the network**: link state, speed, PoE, profile and what is behind the port, when UniFi or another source reports it. - **VLANs**: the VLANs on the port, with **VLANs…** to change them (see [Setting VLANs on switch ports](https://docs.racktrace.io/network/network-plan#port-vlans)). - **Port details**: **Label / description** (e.g. Desk 1.14), **VLAN (note)**, **Port type**, **Speed**, **PoE** (what the port offers, e.g. PoE+), **PoE setting** (on, off, passive 24V, passthrough), **Role** (e.g. WAN, Uplink), **Link aggregation** (e.g. LAG 25+26) and **Switched off (disabled on the switch)**. When the device is linked to a source that [keeps the documentation in sync](https://docs.racktrace.io/integrations/discovery#docs-sync), a note says so: the label, VLANs, PoE setting, switched off and link aggregation follow the source. Click **Save** to keep the changes, or **Delete port** to remove the port and its cable. #### Adding ports **Add ports** on the **Ports** card opens the port-group editor: per group a **Name prefix**, **Start #**, **Count**, **Digits** (2 gives 01, 02 …), **Type**, **Side** (Front or Rear) and **Pass-through** for front/rear pairs. **More** adds speed, PoE, role and the layout on the faceplate. The **Quick add** buttons (**24× RJ45**, **48× RJ45**, **4× SFP+**, **Patch 24**, **Patchbox 24**, **2× PSU**) fill in a common group. The preview line shows which ports will be created. ### Expansion slots and cards Servers and NAS units can have slots (PCIe, OCP 3.0, FlexibleLOM …) where you fit network adapters or HBAs. Their ports are added to the device, named after the slot (`S3-1`, `OCP2-1` …). 1. On the device page, find **Expansion slots** (or the section of the same name in the rack editor's inspector). 2. Click **Fit card** next to a slot. Search for the card (e.g. *sfp28*, *fc 32*); only cards that fit the slot are listed. 3. Optionally add a **Label** (e.g. vMotion, iSCSI A) and a **Serial number**, then click **Fit card**. - **Label / serial / move** changes the label or serial, or moves the card with **Move to slot**: its ports are renamed and the cables stay connected. - **Remove card** removes the card and its ports. If ports are connected, you confirm with **Remove card and cables**. - A model without slots can still record a card in a named slot: click **Card in another slot** or **Fit card** and give a **Slot name**. --- ## Rack editor > Place devices in a rack, number the ports of a patch panel, close empty units with blank and brush panels, patch cables between ports, change the view, look at the rack in 3D, and use building connections and PATCHBOX cassettes. URL: https://docs.racktrace.io/features/rack-editor The rack editor is where most of the documenting happens: drag devices into the rack, patch cables between ports and see every cable route. Changes are saved as you go. ![The rack editor with a switch selected](https://docs.racktrace.io/assets/screens/rack-editor.webp "The rack editor: the device templates on the left, the rack in the middle, and the selected switch in the inspector on the right.") ### Opening the editor Click a rack in the **Locations** tree, or a rack drawing on the room page. You can also use **Open in rack editor** on a device page, **Rack editor** on a trace and **Open in the rack editor** on the floor plan. The editor has three columns: - the **Devices** panel on the left, with the templates from the device library; - the rack drawing in the middle; - the **inspector** on the right, with the settings of the rack, or of the selected device or port. Hide or show the panels with the buttons at both ends of the toolbar. ### The toolbar | Button | What it does | |---|---| | Row view | Shows all racks of the room side by side, with the rack you were in in the middle. In the row view, **Racks n/m** chooses which racks to show. | | ‹ Rack › | The racks of the room: pick one, or step to the previous or next one (`←` `→`). The other rack opens in place — zoom, face and panels stay as they are, and every rack keeps its own undo list. In the row view it moves the row to that rack. Only in rooms with more than one rack. | | Front / Back | Which face of the rack is drawn. Key `R`. | | Diagram / Realistic / 3D | The diagram to patch in, or the rack as the real cabinet with the equipment in it — you select, connect and add there too; in the row view with the cable tray. See [Working in the realistic view](https://docs.racktrace.io/features/rack-cabinets#realistic). **3D** shows that cabinet to turn round and look at, see [The rack in 3D](https://docs.racktrace.io/features/rack-editor#rack-3d). **Door** (realistic and 3D) shuts the door. | | Picture | The rack (in the row view: the racks of the room) as it will look: the real cabinet with the equipment in it, to show or download. See [Rack cabinets](https://docs.racktrace.io/features/rack-cabinets#picture). | | Zoom − / % / + | Zoom out or in (20–200 %). Click the percentage to go back to 100 %. Hidden in 3D, which has a zoom of its own. | | Fit | Fits the rack to the screen. | | Undo / Redo | The tooltip says what will be undone or redone. | | VLANs | Colours ports, or ports and cables, by their untagged VLAN, or shows one VLAN. Only when the tenant has VLANs. | | Network | Shows one network and dims the rest. Only when the tenant has networks. | | Simulation | Colours the cables by the result of the last [simulation](https://docs.racktrace.io/network/simulation). Only after a simulation has run. | | Live | A green (up) or grey (down) dot on every port that UniFi or another source reports. Only when live data exists. | | Cables | Hides all patch cables except the ones of the selected or hovered device or port. | | Outbound | Highlights the ports whose cable leaves this rack. | | Bezels | Hides or shows the front bezels, to see the drive bays and ports behind them. Only when a fitted bezel is in view: not from the back, and not for an optional bezel that is not fitted. | | Saved | The save state: **Saving…**, **Saved** or **Not saved**. Users who may only look see **Read-only**. | Your browser remembers the face, the zoom, and the Cables, Live, VLAN and network choices. ### Placing a device in the rack Find the device in the **Devices** panel: pick a manufacturer, or type in **Search devices…** (every word must match the model, manufacturer, part number or category). Then use one of three ways: - **Drag** the template onto a rack unit. Green units mean it fits, red means it doesn't. The unit you drop on becomes the **top** of the device. - **Click** the template, then click a free U. Press `Esc` or click the template again to stop. - Click the **+** on an empty U. Choose the **Device**, optionally an **ID** and **Name**, and click **Add**. For a patch panel, PATCHBOX or outlet you can give the name of its first port here as well; see [Port numbering](https://docs.racktrace.io/features/rack-editor#port-numbering). The new device is selected and the cursor is in its **Name** field, so you can type the name straight away. - In the **Back** view, new devices are mounted on the back of the rack. Half-depth devices on the other face are drawn hatched. - Full-depth devices take up the U on both faces. - 0U and side-mounted devices, such as PDUs, can be dropped anywhere on the drawing. They are listed under the rack in **0U / side-mounted devices**. - Can't find the model? Add it to the [device library](https://docs.racktrace.io/features/device-library#library) with **Manage device library** at the bottom of the panel. ### Selecting, moving and deleting devices - **Select**: click a device. Its cables are highlighted and the rest is dimmed. Click an empty spot, or press `Esc`, to clear the selection. - **Move**: drag the device by its ID label to another U. In the row view you can drag it into another rack. To move a device to another room, use **Move** on the [device page](https://docs.racktrace.io/features/devices#edit-device). - **Rename**: type in the **Name** or **ID** field of the [inspector](https://docs.racktrace.io/features/rack-editor#editor-inspector). - **Delete**: press `Delete`, or use **Delete device** under **Tools**. This can be undone with `Ctrl`+`Z`, including all its cables. ### Port numbering of patch panels A patch panel from the library numbers its ports 01 … 24. To use your own numbering, such as A-01 … A-24 for panel A, give the name of the **first port**; the other ports follow, and both ends of each port (front and rear, or the top and bottom end of a PATCHBOX cassette) get the same name. This works for patch panels, fibre panels, PATCHBOXes and outlets. - **When you add it**: click the **+** on an empty U, choose the panel and type the first port under **Port numbering — first port**, such as `A-01`. The range it gives is shown beside it (`A-01 … A-24`). - **Afterwards**: select the panel and type the first port in **Port numbering** in the [inspector](https://docs.racktrace.io/features/rack-editor#editor-inspector), then press `Enter`. On the device page, use **Port numbering** on the **Ports** card. The number at the end counts up and keeps its digits: `A-01` gives A-01, A-02 …, `B1` gives B1, B2 …, `101` gives 101 … 124. A `/` becomes `-`, because it separates the parts of a path. Cables, labels and VLANs stay on their ports, the renumbering is in the history, and `Ctrl`+`Z` puts back the old names. When you [change the model](https://docs.racktrace.io/features/devices#change-model) of a panel, it keeps its numbering. ### Blank and brush panels Close empty rack units with **blank panels**, so cold air does not bypass the equipment, and let cables through with a **brush panel**: a panel with a slot of brush strips, like a letterbox. They are under **Blank / brush panel** in the **Devices** panel: blank panels of 1U to 4U, vented blank panels and brush panels of 1U and 2U, and the UniFi OCD panels. Place them like any other device; a blank panel is drawn as a plain plate, a brush panel with its slot and a vented panel with its holes. They have no ports and get an ID such as BP01. To close a whole rack at once, clear the selection and click **Fill free units with blank panels…** in the inspector. Choose the panel; RackTrace fills every gap on the face on screen with as many as fit (with a 2U panel, a gap of one unit stays free). One `Ctrl`+`Z` removes them all again. ### The inspector: device and rack settings The inspector on the right shows the settings of what you selected. Hide or show it with the button at the right end of the toolbar. #### When a device is selected Under the name of the device: its Domotz state and, for a device linked to [Hudu or IT Glue](https://docs.racktrace.io/integrations/hudu-it-glue), **Open in Hudu** or **Open in IT Glue**. - **Settings**: **ID**, **Name**, **Status**, **Network**, **Position (U)**, **Mounted on**, **Full depth**, **Management IP** (with **+** for the next free IP of a VLAN), **MAC address**, **Serial**, **Asset tag**, **Notes** and, for devices with a [front bezel](https://docs.racktrace.io/features/rack-editor#bezels), **Front bezel fitted**. Patch panels, PATCHBOXes and outlets also have **Port numbering** (see [Port numbering](https://docs.racktrace.io/features/rack-editor#port-numbering)). Patch panels, PATCHBOXes and blank panels have no **Management IP**, **MAC address**, **Serial** or **Asset tag** — those fields only show when one is filled in already. A field is saved when you leave it or press `Enter`; `Esc` puts the old value back. - **Expansion slots**: fit, move and remove cards (see [Expansion slots and cards](https://docs.racktrace.io/features/devices#cards)). - **Tools**: - **Manage building connections** (see [Building connections](https://docs.racktrace.io/features/rack-editor#building-connections)) - **Trunk to another rack…** (see [Trunks](https://docs.racktrace.io/features/row-view-and-trunks#trunks)) - **Bulk connect…** (see [Bulk connect](https://docs.racktrace.io/features/cables-and-tracing#bulk-connect)) - **Cassette types (UTP / fibre)…** (see [PATCHBOX cassettes](https://docs.racktrace.io/features/rack-editor#patchbox)) - **Port profiles (VLANs)…** (see [Port profiles](https://docs.racktrace.io/network/network-plan#profiles)) - **Change model…**, **Add ports…** and **Delete device** - **Ports**: every port with its **trace chain**, the path from end to end through patch panels and outlets. Filter with All / Connected / Free or **Filter ports, labels or paths…**. Click a port to select it in the drawing. #### When nothing is selected The inspector shows the rack: its settings (ID, name, **Cabinet model** — see [Rack cabinets](https://docs.racktrace.io/features/rack-cabinets#cabinet-model) —, **Height (U)**, **Position in room**, asset tag, notes), a summary, **Outbound connections**, **Links to other racks** and the buttons **Picture — as it will look**, **Row view**, **Printable report**, **Labels & QR codes**, **On the floor plan**, **Rack history**, **Fill free units with blank panels…** (see [Blank and brush panels](https://docs.racktrace.io/features/rack-editor#blank-panels)) and **Delete rack…**. ### Patching cables 1. Click a free port. A bar says **Connecting …**. 2. Click the second port. The cable is drawn in its colour along the cable tray. Or **drag** from one port to the other. To cancel, press `Esc` or click the first port again. - **Move a cable**: drag a connected port onto a free port. The other end stays where it is; the cable keeps its label, type, colour and length. - **Ports elsewhere**: select the port and click **Connect to…** in the port panel. Choose the other device (anywhere in the tenant), then the port, then the cable details. - **Disconnect**: select the port and click **Disconnect**. Undo brings the cable back. - **Cable details**: click the cable chip in the port panel to change the **Label**, **Type**, **Colour**, **Length (m)** and **Planned — not installed yet**. New cables get a label like `C-0042` and a type and colour that fit the port: fibre ports get Fiber OM4 (aqua), SFP ports a DAC, power ports a power cable and copper ports Cat6 (blue). Hover a port to see its path, type, VLANs, where it goes and the live state. The other end lights up. Cables that leave the rack end in an arrow with a label, such as `LA 32×`. Planned cables are dashed. ### Views: front and back, zoom, VLANs and live state - **Front / Back** (`R`): the back shows patch panel rear ports, server ports and power supplies. - **Zoom**: `+` and `−`, `Ctrl` + scroll wheel (around the pointer) or pinch on a touchpad. **Fit** fits the rack to the screen. - **Move around**: drag with the right or middle mouse button; let go while still moving and the drawing glides on. A selection, or a cable you are halfway through connecting, stays as it is. - **To another rack**: keep dragging with the right mouse button past the left or right edge. The drawing stretches and a tab shows the previous or next rack of the room; let go when it says **Release to open**, or let go earlier to stay. `←` and `→` and the rack picker in the toolbar do the same. You stay at the same height in the rack, and the browser's Back button goes to the rack before. - **VLANs**: - **Colour ports by untagged VLAN**. - **Colour ports + cables by untagged VLAN**: also colours the cabling through patch panels and PATCHBOXes up to the outlet. A legend below the rack counts the cables per VLAN. - Choosing one VLAN highlights the ports and cables that carry it (dashed where it is tagged) and dims the rest. - **Network**: shows one network (IT, PRD …) and dims the rest. - **Outbound**: highlights the ports that leave the rack. They are listed in the inspector under **Outbound connections**; click one to jump to it. ### The rack in 3D Click **3D** in the toolbar to see the rack as the real cabinet, all round: its colour and doors, the side panels and roof, and every device as deep as it is, with its front and its back. It is the same drawing as the realistic view, so what you see in one you see in the other. In the row view the racks stand side by side, with the cable tray hanging above them — seen from every side, also straight from beside the row. Your browser remembers the choice. - **Turn**: drag with the mouse or a finger; let go while still moving and it turns on a little. The arrow keys turn it too, when the view has the focus. - **Move up and down** (and sideways): scroll, drag with the right mouse button or with `Shift` held, or use two fingers on a touchpad or screen — as in Diagram and Realistic. The keys: `Page Up` / `Page Down`, or `Shift` + an arrow key. Turning then turns round the part you are looking at. - **Zoom**: `Ctrl` + scroll (`Cmd` on a Mac) or a pinch zooms in where the mouse or your fingers are; **−** and **+** in the bar at the bottom (or the keys) zoom in on the middle. - **Reset**: **Reset** in the bar, `Home` or a double-click on an empty spot shows the whole rack again, straight from the side you are looking at. - **Standpoints**: **Left** and **Right** (from the front, at an angle), **Front** and **Back**; each shows the whole rack. `0` goes back to straight from the front. **Front** / **Back** in the toolbar turns the rack to that side, and follows when you turn it yourself. - **Door**: opens or shuts the doors of the side you are looking at; they swing on their hinges. In a row, a door that hinges next to the neighbouring rack opens just to a right angle, so it never swings over that rack. - **Side panels**: takes the side panels off, to see how deep the equipment is and how it fills the cabinet. - **Cables** and **Bezels** work as in the realistic view. A cable to the back of a device that hangs at the other side of the rack (the rear of a patch panel, seen from behind) runs from the cables at the rear straight into its port, a device depth into the cabinet. A click on a device or a port selects it, as in the realistic view: the inspector shows it, its box is outlined and the cables of the selection light up. 3D is for looking: to add, move or connect, switch to **Diagram** or **Realistic** — the selection stays. Without a graphics card (for example over a remote desktop) the browser draws everything itself. To keep turning smooth, the cables and the doors are then left out while the rack turns — the doors as their outline — and come back as soon as it stops. With *reduce motion* set on your computer the rack jumps to a standpoint and the doors open without swinging. A browser that cannot show 3D has no **3D** button. ### Front look and front bezels Many devices are drawn with their real front: rack ears, drive bays, displays, status LEDs, buttons and vents where they sit on the device. Some also have a front bezel: - a **standard** bezel ships with the device, such as the bezel of a UPS or battery pack, or the front door of a SIMATIC IPC; - an **optional** bezel is an accessory you may have fitted, such as an HPE security bezel. A bezel is drawn when it is fitted. To record that for one device, tick or clear **Front bezel fitted** in the [inspector](https://docs.racktrace.io/features/rack-editor#editor-inspector), or use **Fit** / **Remove** next to **Front bezel** on the device page. This can be undone and is in the history. Want to see the drive bays and ports behind the bezels? Click **Bezels** in the toolbar to hide all bezels; click it again to show them. Your browser remembers the choice. The button is only there when a fitted bezel is in view: an optional bezel (such as the HPE security bezel) is drawn once you tick **Front bezel fitted**. ### Saving and undo Every change is saved at once; watch the **Saved** indicator. If something cannot be saved, it shows **Not saved** with a message and the rack is reloaded. `Ctrl`+`Z` undoes and `Ctrl`+`Y` (or `Ctrl`+`Shift`+`Z`) redoes the last 100 steps. Undo covers: - adding, moving and deleting devices, including a device with all its cables; - field changes; - connecting, disconnecting and moving cables; - trunks, building connections, cards, cassettes and VLAN settings; - port numbering and filling a rack with blank panels; - changing the model. Every rack has its own undo list: `Ctrl`+`Z` only undoes changes in the rack on screen (the tooltip and the message name the rack, e.g. *Undone: Add Switch in RK01*), and when you step to another rack and back, its list is still there. The list starts empty each time you open the editor. While a save is running, undo and redo are off for a moment. A device you delete and bring back is the same device again — its labels, QR codes and history still point to it, and its cables are back on their ports. ### Building connections Use this to document the permanent cabling from a patch panel to the floor boxes or wall outlets in another room, all in one go. 1. Select the patch panel and choose **Tools → Manage building connections**. 2. Pick the **Start at port** and the **Number of connections**. 3. Choose the **Target room**, then the **Cable type** (Cat6a by default), **Colour** and **Length (m)**. 4. Tick the **Target devices**. Devices with free rear ports are ticked by default. 5. Check the **Preview**: ports are matched in order and ports already in use are skipped. 6. Click **Create connections**. The existing building connections are listed below the form; remove one with its delete button. ### PATCHBOX cassettes Each cassette of a PATCHBOX is a retractable patch cable with a top end ↑ and a bottom end ↓ on the front. A trace runs through the cassette like through a patch panel. 1. Select the PATCHBOX and choose **Tools → Cassette types (UTP / fibre)…** (or **Cassette types** on its device page). 2. Set each cassette to **UTP Cat.6a**, **Fibre LC-LC**, **Fibre LC-SC** or **Fibre SC-LC**, or use **Apply to range**, **All UTP** or **All LC-LC**. 3. Click **Save**. Cables stay connected; check their cable type when a connected cassette changed. One cassette can also be changed with **Cassette type** in the port panel. --- ## Row view and trunks > All racks of a room side by side, and trunks: named bundles of cables between two racks. URL: https://docs.racktrace.io/features/row-view-and-trunks Rooms with more than one rack have a row view, with the racks side by side and the cables between them. Bundles of permanent cables between two racks are documented as trunks. ### Row view: all racks of a room The row view shows all racks of a room side by side, with U1 aligned and the cables between racks over a cable ladder. Open it with **Row view** in the editor's toolbar or on the room page. ![The row view with the racks of a server room side by side](https://docs.racktrace.io/assets/screens/row-view.webp "The row view: all racks of a room side by side, with the cables between them over the cable ladder.") - Racks are ordered by their **Position in room**. - **Racks n/m** chooses which racks to show; cables to hidden racks are shown as outbound. - Patch between racks by clicking or dragging, as within one rack. - Drag a device from one rack into another. - Click a rack's ID above it to open that rack on its own. - Move along the row by dragging with the right mouse button, with `←` and `→` (the previous / next rack to the middle of the screen), or by picking a rack in the toolbar. On a first visit a long row is shown at 50 %, so the ports stay readable; **Fit** shows the whole row. ### Trunks between racks A trunk bundles permanent cables between two racks, such as 24× Cat6a from panel B in RK001 to panel A in RK002, or 12× OM4 between fibre panels. 1. Click **New trunk** on the room page or in the inspector, or **Tools → Trunk to another rack…** on a device. 2. For **End A** and **End B**, choose the **Rack**, **Device**, **Side** (Rear or Front) and **First port**. The form shows how many ports are free. 3. Set the **Number of cables**, the **Trunk name** (empty = automatic, e.g. T-RK001-RK002), **Cable type**, **Colour**, **Length (m)**, **Network** and, for future cabling, **Planned — not installed yet**. 4. Check the preview and click **Create trunk**. The cables are labelled `-01`, `-02` … - **Edit**: click the trunk chip in **Links between racks** or in the port panel. You can rename it (its cables are renamed too) and change type, colour, length, network and planned status for all its cables. - **Ungroup** removes the trunk but keeps its cables. **Delete trunk** deletes the trunk and its cables (undo is possible). - **Group existing cables**: in **Links between racks**, the **+** next to a group of direct cables makes a trunk of them. --- ## Rack cabinets and the picture of a rack > Give a rack its real cabinet (Rittal, APC NetShelter and others) and show the customer how it will look, with the equipment in it. URL: https://docs.racktrace.io/features/rack-cabinets A rack can be a real cabinet: a Rittal VX IT, an APC NetShelter SX, a wall-mounted FlatBox and so on. RackTrace then knows its size, colour and doors, and draws the rack as that cabinet — with everything that is mounted in it — so you and your customer see how it will look. ### Choosing the cabinet of a rack 1. Open the rack in the [rack editor](https://docs.racktrace.io/features/rack-editor). With nothing selected, the inspector shows the rack's settings. 2. Choose the **Cabinet model**. The models are grouped by maker and series; the article number is behind the name. 3. The rack takes the height of the model (for example 42U). When a device sits higher than the new model allows, you get a message and nothing changes. You can also choose the model when you create a rack (**New rack** on the room page) or with **Edit** on the rack. **None — a plain 19" rack** takes the model off again; the height stays. The model shows in several places: - the rack editor draws the frame in the colour of the cabinet and names the model next to **FRONT** / **BACK**; - the [floor plan](https://docs.racktrace.io/features/floor-plans#plan-place) draws the rack at the real width and depth of the cabinet (without a model: 0.6 × 1 m); - the room page names the model under each rack; - the picture of the rack and the [report](https://docs.racktrace.io/features/export#report) draw the real cabinet. Changing the model can be undone (`Ctrl`+`Z`) and is in the history of the rack. ### Working in the realistic view In the rack editor, **Diagram / Realistic** in the toolbar switches between the diagram you patch in and the rack as the real cabinet with the equipment in it. Your browser remembers the choice. In the realistic view you work as in the diagram: - click a device to select it and see it in the inspector; - click a port, then a second port, to connect them — or drag from port to port; hover a port to see where it goes; - click a free rack unit to add a device there, or drag a device from the panel on the left onto a unit; - **Front** / **Back**, zoom, moving around and the rack picker work as always; **Door** shuts the door of the cabinet (devices can still be clicked through it), **Bezels** and **Cables** show or hide the bezels and the patch cords. **The cables** are drawn as a tidy installer would run them. Every cable is its own cord in its cable colour, from its port to the port it is connected to: - a patch cord to a device right above or below (a patch panel and its switch, with at most a cable manager or two units in between) goes straight there, one next to the other, without crossing; - cables over a longer distance go sideways into the side room of the cabinet, run there as a bundle along the mounting angle — tied every few units — and come out again at the port they end on; a cable to a 0U PDU runs to the PDU in the side room; - cables that leave the rack are bundled and go up through the roof; above a single rack you see where they go and how many (`↑ HQ/00/LA 4×`); - a cable whose other end is on the other side of the cabinet, or on a device seen from behind, is drawn fainter; - a cable manager with a cover hides the cords that run in it: you see them go in at the top and come out at the bottom, the rest runs behind the cover. Click the cover to select the cable manager. Click a port or a device to light up its cables; the other cables fade. A cover with one of those cables behind it turns see-through, so you can follow the cable. The cable managers with a cover are **Cable Manager 1U with Cover** and **Cable Manager 2U with Cover** in the device library (under **Cable manager**); an open one (**Cable Manager 1U**) shows its fingers and the cords in it. A template of your own counts as one with a cover when its model says so (*cover*, *deksel*). In the [row view](https://docs.racktrace.io/features/row-view-and-trunks#row-view) the racks stand against each other as in the room, with a **cable tray** above them. The cables between two racks come out of the roof of the one, run tied together through the tray and go down into the other. Cables to a rack elsewhere run to the end of the tray, with where they go and how many (`→ HQ/01/TR/RK101 · 2×`). Moving a device by dragging, the cable routes and the VLAN, network, live and simulation colours are in the diagram. ### The picture: how it will look Click **Picture** in the toolbar of the rack editor, or **Picture — as it will look** in the inspector. In the [row view](https://docs.racktrace.io/features/row-view-and-trunks#row-view) and with **Picture** on the room page you get all racks of the room side by side, standing on the same floor, as they stand in the room — with the cable tray and the cables between them. The picture is the same drawing, to show or download. It is drawn to scale: the cabinet with its frame, plinth or castors, the 19" mounting angles with their unit numbers, and every device with its real front — drive bays, displays, fans, the ports where they sit on the device and the patch cords in their cable colour. A device mounted on the other side is seen deeper in the cabinet, darker. On the back, 0U PDUs stand upright in the side room of the cabinet. | Option | What it does | |---|---| | Front / Back | Which side of the racks you see. | | Door closed | Shows the front or rear door shut: the equipment shows through the perforation or the glass. | | Patch cords | The plugs of the connected cables in their colour. | | ID labels | The ID of each device on a label at its mounting ear. | | Unit numbers | The unit numbers next to the mounting angles. | Click the picture to see it at full size; click again to fit it. **SVG** downloads the drawing (sharp at any size, for a quote or a presentation), **PNG** a picture of it. A rack without a cabinet model is drawn as a plain black 600 mm cabinet; the picture tells you which ones. > **Tip** > > Plan the rack before it is built: place the devices with status **planned** in the rack editor and send the customer the picture. Planned devices have a dashed blue outline. ### The cabinets in the library Open **Library & reports → Device library → Rack cabinets**. The built-in library has 150+ cabinets from the makers' data sheets: - **Rittal**: VX IT (42U and 47U, 600 and 800 wide, vented or glazed, also the pre-configured ones with plinth), the older TS IT, FlatBox, AX IT and AX / EL wall-mounted enclosures, DK Data Rack open frames; - **APC**: NetShelter SX and SX Gen 2 (24U to 52U, also the white ones), NetShelter SV, Easy Rack, NetShelter WX wall-mounted cabinets and the open frames; - **Triton**, **Minkels**, **Lande**, **Eaton**, **Vertiv**, **Conteg**, **HPE**, **Digitus** and **Panduit**: their most common cabinets. Filter by maker or kind, or search: every word must match, for example *vx it 800*, *42u 1200* or *ar3150*. Click a cabinet to see it with its door open and shut, its size, colour, doors and load, and a link to its data sheet. Cabinets that are no longer sold say so in their notes, with their successor. **New cabinet** (or **Duplicate** on one that is close) adds your own, for all tenants (administrators) or for one tenant: manufacturer, model, article number, height in U and outside size in mm, colour, front and rear door, perforation, handle, plinth or feet, and the name on the cabinet. The drawing next to the form follows what you fill in. Changing the height of a cabinet changes the racks of that model too. Removing a built-in cabinet hides it from the library; racks that are that model keep it. Deleting your own cabinet makes its racks plain 19" racks of the same height. Administrators bring removed or edited built-in cabinets back with **↺** on the **Device templates** tab. --- ## Cables and tracing > Connect cables from the device page, connect a range of ports at once, and follow a cable from end to end. URL: https://docs.racktrace.io/features/cables-and-tracing Besides patching in the rack editor, you can connect cables from the device page, connect whole ranges at once, and follow any cable from one end to the other. ### Connecting a cable from the device page 1. On the device page, click a free port and then **Connect cable**. 2. **1. Choose the other device**: type in **Filter by ID, path, name…**. Devices in the same rack and room are listed first, with the number of free ports. 3. **2. Choose the port**: ports in use are greyed out. 4. **3. Cable details**: **Cable label** (empty = automatic, e.g. C-0042), **Type**, **Colour**, **Length (m)** and **Notes**. 5. Click **Connect**. To change a cable, open one of its ports and click **Edit cable**. To remove it, click **Disconnect**. ### Bulk connect: a range of ports in one go Connects a range one-to-one, for example patch panel ports 01–24 to switch ports 01–24. 1. Click **Bulk connect** on the device page, or **Tools → Bulk connect…** in the rack editor. 2. Choose the **Start port** on this device and the **Number of connections**. 3. Choose the **Target device** and its **Start port on target**. 4. Set the **Cable type**, **Colour** and **Length (m)** (Cat6, yellow, 0.5 m by default). 5. Check the preview and click **Connect all**. Each range stays on the side (front or rear) of its start port. If a port in the range is taken, the preview says why it cannot connect. ### Tracing a cable end to end Open a trace with the trace icon in the device's **Port list**, **Trace** in the port dialog, **Full trace** in the rack editor, or a cable from the search results. ![A trace from a workstation to the switch](https://docs.racktrace.io/assets/screens/trace.webp "A trace from a workstation, through the floor box, a patch panel and a PATCHBOX, to the switch.") - The title shows the port, with the number of cables and devices on the way and the total length of the cables with a documented length. - **A-end** and **B-end** show both ends, with device and location. - **Path** lists every device on the way. Ports joined inside a device, such as a patch panel's front and rear, show as `01 ⇄ 01 (rear)`. Between the devices you see each cable in its colour, with label, type and length. - If the path loops back on itself, a warning says **This path contains a loop — check the cabling.** Example of a trace chain: `HQ/00/LA/PC01/ETH1 → HQ/00/LA/FB01/01 → HQ/00/SL/RK001/A/01 → HQ/00/SL/RK001/SW01/01`. --- ## Floor plans > Put the drawing of a floor in RackTrace, draw the rooms, place racks, outlets and access points, and check every cable length. URL: https://docs.racktrace.io/features/floor-plans Per floor, put the drawing in RackTrace and place the rooms, racks, outlets, access points and cameras on it. RackTrace then shows every cable route with its length and warns when a permanent link gets too long. ![A floor plan with rooms, a rack, floor boxes and an access point](https://docs.racktrace.io/assets/screens/floor-plan.webp "A floor plan: the drawing with the rooms, the rack, floor boxes and an access point, and the cable routes to the rack.") ### Opening a floor plan - **Floor plan** on a floor page, or click the small picture of the plan there. - **Floor plan** next to each floor on the site page. - **Floor plan** on a room page (opens with that room selected) or a device page (zoomed in on the device). - **On the floor plan** in the rack editor's inspector. If the site has more than one floor, the floor IDs above the plan switch between floors. ### Adding the drawing Click **Add drawing** and choose a file of at most 25 MB. - **PDF**: choose the **Page** if the file has several, and fill in the **Scale of the drawing** from the title block (e.g. 1:100). Click **Use this page**. With a scale, the plan knows its metres at once. - **DXF** (AutoCAD): check the **Units of the drawing** (read from the file) and tick the **Layers** to show. Click **Use this drawing**. The scale comes from the file. Only ASCII DXF can be read; save a binary DXF as ASCII DXF or as PDF. - **PNG, JPG or SVG**: uploaded as they are. Set the scale afterwards with the ruler. - **DWG** cannot be read in the browser. Save it as DXF (best: keeps scale and layers) with AutoCAD *Save As*, the free DWG TrueView or the ODA File Converter, or as PDF. Once there is a drawing, the button is called **Drawing**: change the **Background strength**, **Replace…** the file or **Remove** it. Rooms and positions stay; check them after changing the drawing. The drawing is stored with the documentation, so it is in the backups and the tenant export. Without a drawing you work on a grid of 40 × 25 m with a line every metre. ### Setting the scale 1. Click **Scale** in the toolbar (key `M`), or **Set the scale** in the scale bar or the floor panel. 2. Click two points whose distance you know, such as both ends of a wall. 3. Enter the **Distance in metres** and click **Set scale**. A scale bar appears at the bottom of the plan. Without a scale, RackTrace cannot estimate cable lengths. ### Drawing rooms 1. Click **Room** (key `R`) and drag a rectangle, or click **Shape** (key `P`) and click the corners one by one. Close a shape by clicking the first point, pressing `Enter` or double-clicking. `Backspace` removes the last point. 2. In **Which room is this?**, pick the RackTrace room it is, or **+ New room on this floor** with an ID and name. 3. Click **Save**. Rooms that exist but aren't drawn yet are listed on the left under **Rooms not drawn**; click one to draw it straight away. Click a room to select it. The inspector shows its devices, racks and floor area, with **Room page**, **Labels for this room**, **Edit the shape** and **Remove the shape**. While editing the shape: drag a corner to move it, double-click a corner to remove it, double-click an edge to add one. **Done editing** or `Esc` ends it. ### Finding the rooms in the drawing RackTrace can find the rooms in the drawing itself: the open spaces between the walls, split at the door openings. 1. Click **Find rooms** (key `D`), or **Find the rooms in the drawing** in the floor panel. The rooms found are outlined on the plan and numbered, and listed on the right. 2. Check each room. The name and number come from the texts of the drawing: those in a DXF or SVG drawing, and those of the PDF page you just uploaded. For a drawing uploaded earlier from a PDF, click **read them from the PDF of the drawing…** and choose that PDF again. Change the **ID** and the name where needed; leave the ID empty to have one made from the name. 3. Tick the rooms you want, or click a room on the plan to tick it. Rooms that are already drawn start unticked; tick one to give it the new outline. Under each room you can also pick a room of this floor that isn't drawn yet, to give that room the outline. 4. Click **Create … rooms**. Everything is created at once; one `Ctrl`+`Z` takes it back. If rooms run into each other, set **Openings up to … m separate two rooms** higher (wide double doors); if a narrow room or corridor is missing, set it lower. In a drawing full of furniture or hatching with thick walls, tick **Leave out thin lines** — the thin lines of windows are then left out too, so check the rooms along the outside walls. Set the scale first: without it RackTrace takes the drawing as 40 m wide. Check the outlines afterwards and change them with **Edit the shape** where needed. ### Placing racks and devices Everything of the floor that isn't on the plan yet is listed on the left under **Not on the plan**, grouped into racks, access points, outlets & floor boxes, cameras, workstations, phones, printers and other devices. Search with **Find on this floor…**. 1. Click an item in the list, then click on the plan where it is. Or drag it from the list onto the plan. 2. Drag a symbol to move it. A device dropped in another room of the floor moves to that room. 3. Racks are drawn at their real size: that of their [cabinet model](https://docs.racktrace.io/features/rack-cabinets#cabinet-model), or 0.6 × 1 m without one; the thick side is the front. Select a rack and press `R`, or use **⟲ 90°** / **⟳ 90°**, to turn it. Select an item to see its details: for a device the room, model, IP, live state and every port with where it goes; for a rack its devices and what is patched there. `Delete` or **Remove from the plan** takes the item off the plan; it stays documented. ### Cable routes and lengths A line runs from every outlet and access point to its patch location: the rack it is cabled to. A patch cable from a device to the outlet it is plugged into is dotted. Planned cables are dashed. Turn the routes on or off with **Cable routes** in the toolbar. - With nothing selected, the floor panel sets the route style: **Along walls** (an L-shaped route: one horizontal and one vertical leg; it doesn't follow the walls on the drawing) or **Straight**. - The estimated length is the route plus **Extra per cable (rises, slack) in m**, 6 m by default, set in the same panel. When a cable has a documented length, that length is used. - A route turns **orange** above 80 m and **red** above 90 m, the limit for a permanent link. The floor panel lists the routes longer than 90 m. - Hover a route to see the device, the rack and the length. ### Creating outlets and access points on the plan Click **Add** and choose **Outlet / floor box**, **Access point**, **Camera** or **Other device**, then click on the plan where it goes. The floor needs at least one drawn room. #### A new outlet or floor box 1. Check the **Room** and choose the **Model**: wall outlet 1× / 2× / 4×, floor box 2× / 4× / 6×, ceiling outlet 1× / 2×, or your own template. 2. Under **Permanent link to a patch panel**, choose the **Patch panel**. Its first free rear ports are connected to the rear ports of the outlet. 3. Choose the **Cable** type. **Length (m)** is filled in from the plan when the panel's rack is placed. 4. Click **Create**. #### A new access point, camera or other device 1. Check the room, model, ID, name and **Management IP**. 2. Under **Patched into**, choose the nearest free outlet port (it's suggested when it's within 10 m), or **+ New ceiling outlet here, cabled to a patch panel** and pick the patch panel. 3. Click **Create**. With a new ceiling outlet, RackTrace places the outlet next to the device, cables it to the panel and patches the device into it. One `Ctrl`+`Z` removes everything that was just created. Your browser remembers the last model you chose. ### Live status on the plan Turn on **Live** in the toolbar. Every symbol gets a dot: green for online, red for offline, grey for unknown. Access points show their number of WiFi clients. The status comes from UniFi or another discovery source, or from Domotz, and is refreshed every minute. ### Printing the floor plan 1. Click **Print**. 2. Choose **Paper (landscape)**: A4 or A3. Tick **Cable routes**, **IDs of rooms, racks and devices** and **List of ports with their patch location and length (next pages)** as needed. 3. Click **Print…**. To get a PDF for the installer, choose **Save as PDF** in the print dialog. The first page has the plan with its scale and a legend; the next pages list every port with its patch location, cables and length. The printable report of a site includes every floor plan too. --- ## Labels and QR codes > Print cable labels with both ends, labels for outlets and patch panels, and QR stickers for racks and devices. URL: https://docs.racktrace.io/features/labels Print labels that match the documentation: cable labels with both ends, labels for outlets and patch panel ports, and QR stickers that open the rack or device in RackTrace. ### Opening labels and choosing what for Open **Library & reports → Labels**, or use **Labels** on a site, room or device page, **Labels & QR codes** in the rack editor, or **Labels** on the floor plan. ![The labels page with cable labels in the preview](https://docs.racktrace.io/assets/screens/labels.webp "Cable labels for a P-touch printer, with the preview at real size.") 1. Choose what for in **For**: everything, a site, a floor, a room, a rack or one device. 2. Choose the tab: **Cables**, **Ports & outlets** or **Racks & devices**. 3. Everything is selected. Narrow it with **Filter…**, **All**, **None** or by clicking rows. 4. Choose the printer and label under **Printer & layout** and check the **Preview**. ### Cable labels A cable label shows the cable ID and both ends, such as `C-0001 · SL/RK001/A/01 (R) · LA/FB01/01 (R)`. The part both ends share is left out. - **Layout**: **Flag — folds around the cable** (text on both halves) or **Straight label** for sheets and sleeves. - **Part around the cable (mm)** for a flag: about 3× the cable diameter, 20 mm for Cat6. - **Labels per cable**: **2 (both ends)** or **1**. - **Ends**: **Short** or **Full path**. - **Also cable type and length**, e.g. *Cat6 · 3 m*. ### Port and outlet labels Labels for the ports of floor boxes, wall outlets and patch panels, with the other end of the permanent link: `FB01/01 → SL/RK001/A/01` on the outlet, `A/01 → LA/FB01/01` on the panel. For a single device (a switch, say) all its ports are listed. - **Layout**: **One label per port**, or **Strip per patch panel / outlet** with a block per port. For a strip, set **Width per port (mm)** to the pitch of the panel and the **Ports per strip**. - **Where it goes**: the full path, or only device / port. - **Use the port label when one is set**: a filled-in port label is used as the port's name. ### QR stickers for racks and devices On the **Racks & devices** tab, tick **QR code** and choose the lines: **Name**, **IP address**, **Model**, **Serial / asset tag** and **Location**. - **QR code position**: **Left** or **Right** of the text. - **Own line**: a text printed on every sticker under the other lines, such as *Service desk 020 123 4567*. - **Logo**: **Above the text**, **Beside the text** or **None**, once an administrator has uploaded a logo (see [Your logo and the standard settings](https://docs.racktrace.io/features/labels#labels-standard)). The QR code holds a short, stable link such as `https://yourcompany.racktrace.io/q/d12` (or `/q/r3` for a rack). Scanning it opens the device or rack; a phone that isn't signed in gets the sign-in page first. **Address in the QR code** lets you use another address; leave it empty for the current one. ### Your logo and the standard settings Administrators set these for everyone in the organization, on the labels page itself. **A logo on the QR stickers**: 1. Open the **Racks & devices** tab. 2. Under **Logo**, click **Upload…** and choose a PNG, JPG, WebP or SVG image — or **Use the app logo** for the logo under **Login & security**. 3. Choose **Above the text** or **Beside the text** and check the **Preview**. Label printers print only black. With **Make it black and white** (on by default) the logo becomes black and white when you upload it, and the empty edges are cut off. Untick it before uploading to keep a logo that is black and white already as it is. **Change…** replaces the logo, **Remove** takes it off all labels. > **Tip** > > A wide logo fits best **Above the text**; a square one also fits **Beside the text**. On tape of 9 or 12 mm a logo gets very small: use a LabelWriter label or an A4 sheet. **The standard settings**: choose the printer, label, layout and lines on the three tabs, then click **Save as standard** at the bottom of **Printer & layout**. Everyone in the organization then starts from these settings — also those who had changed them before. Someone who changes them afterwards sees **Back to the standard**. **Remove the standard** brings back the RackTrace defaults. The printer adjustments, the **Start at label** position and the zoom of the preview are not part of the standard: they belong to the computer and its printer. ### Printers and label sizes | Printer / media | Sizes | |---|---| | Brother P-touch (TZe tape) | 9, 12, 18 and 24 mm | | DYMO LabelManager (D1 tape) | 9, 12, 19 and 24 mm | | DYMO LabelWriter | 11355, 11354, 99010, 99012 | | A4 sticker sheets | Avery L4732, L7651, L7160, L7163, Avery Zweckform 3474 | | Your own | **Custom label size…** or **Custom A4 sheet…** (columns, rows, margins, pitch) | - On tape every label is a page. Its length follows the longest label, or set a **Label length (mm)**. - On a partly used sheet, set **Start at label** to the first free position, counted left to right, top to bottom. - The preview shows the labels at their real size and warns when the text gets too small. ### Printing labels and exporting CSV 1. Click **Print … labels**. 2. In the print dialog, choose the label printer (or your normal printer for sheets), scale 100 % (*Actual size*, no *Fit to page*) and margins **None**. For a LabelWriter, also choose the matching label size. 3. For sheets, try it on plain paper first and hold it against a sheet. **Printer adjustments**: - **Shift right (mm)** and **Shift down (mm)** line up a sheet that prints a little off. - **Rotate 90°** is for printers that feed the label sideways. No printer driver, such as with a DYMO LabelManager PnP? Click **CSV**: it has the same texts and the QR address per label, for P-touch Editor (*Database → Connect*) or DYMO Connect (*Import data*). Your browser remembers the printer, options and adjustments per tab, on top of the [standard settings](https://docs.racktrace.io/features/labels#labels-standard) of your organization. --- ## Device library > The built-in device templates, making your own templates, and the expansion card library. URL: https://docs.racktrace.io/features/device-library The device library holds the templates you place in racks and rooms. A template brings the real port layout with it, so a new device has the right ports straight away. ### The device library Open **Library & reports → Device library**. It has 1,200+ built-in templates with the real port layout: the complete UniFi range, Cisco Catalyst and Business, Aruba, APC and Eaton PDUs and UPSs, Siemens SCALANCE, HPE, Synology and HP servers and storage, patch panels, PATCHBOX, blank and brush panels, cable managers (open or with a cover) and generic equipment. ![The device library](https://docs.racktrace.io/assets/screens/device-library.webp "The device library with the built-in templates, filtered by category.") - Filter by category, by manufacturer and with **Built-in & own** / **Built-in only** / **Own templates only**. In the search, every word must match: try *pro max 24*, *sfp28* or *poe++*. - Click a model to see its details and faceplates; **Preview ports** does the same from the list. - **Duplicate** a similar template to make your own variant, **Edit** to change one, or delete it. - **Export** downloads the library as JSON; **Import** reads such a file, for example from another installation. - Administrators can click **↺** (**Restore built-in templates**) to bring removed or edited built-in templates back to the original. Your own templates are not touched. > **Note** > > Changing a template only affects devices you add afterwards; existing devices keep their ports. Built-in templates update automatically, unless you edited them. ### Making your own template 1. Click **New template**, or **Duplicate** on a template that is close. 2. Fill in **Manufacturer**, **Model / name**, **Part number / SKU**, **Category** and **Height (U)** (0 for devices that aren't rack-mounted). Tick **Full depth** when it fills front and rear. 3. Under **Available to**, choose **Global — all tenants** (administrators) or only the current tenant. 4. Add the **Ports** with the port-group editor (see [Adding ports](https://docs.racktrace.io/features/devices#port-dialog)). For a patch panel, tick **Pass-through** so the front and rear ports are connected inside. 5. Optionally add **Expansion slots** (name, kind, side and position on the faceplate), a **Datasheet / source link** and **Notes**. 6. Click **Save**. ### Rack cabinets The **Rack cabinets** tab holds the cabinets a rack can be — Rittal, APC NetShelter and others — with their size, colour and doors. See [Rack cabinets](https://docs.racktrace.io/features/rack-cabinets#cabinet-library). ### Expansion cards in the library The **Expansion cards** tab holds network adapters, FC and SAS HBAs, OCP, FlexibleLOM, Synology and HP Flex IO modules. **New card** adds your own: fill in the model, **Fits in** (the slot kind) and the **Ports on the bracket**. A card's ports get their names from the slot it is fitted in (`S3-1`, `OCP2-1` …), with the card's prefix in front. --- ## History and search > Find every change with who made it and when, and search across all your tenants. URL: https://docs.racktrace.io/features/history-and-search Every change in RackTrace is recorded, and the search box in the top bar looks across all your tenants. ### History Every change is recorded with who made it, when, and the old → new value. Open **Library & reports → History**, or **View all** under the history of a site, room, rack or device. ![The history page](https://docs.racktrace.io/assets/screens/history.webp "Every change, with who made it and when.") - Filter on the tenant, the type of object (sites, devices, ports, cables, VLANs …), the action (created, updated, moved, deleted, connected, disconnected, imported), the user, a text and the dates **From** and **To**. - Click an object's name to open it. **∅** means empty. - **Load more** shows older changes. ### Search Type in the search box in the top bar. Results appear after two characters, or straight away with `Enter`, across all your tenants. Search looks in: - the IDs and names of sites, floors, rooms, racks and devices; - management IPs, serial numbers, asset tags, models and manufacturers; - port labels and VLAN notes; - cable labels; - addresses and notes; - **VLANs**: by number (*30*, *vlan 30*) or by name or purpose (*Guest*). A VLAN with exactly that number comes first; - **IP addresses**: an exact address (*10.0.0.5*), the start of an address (*10.0.0.*) or a subnet (*10.0.0.0/24*, everything in use in it). RackTrace looks at management IPs, IP assignments, DHCP reservations and the devices and clients a discovery source sees. Each result shows the VLAN that holds the address; - **MAC addresses**, complete or the first part, with or without separators (*aa:bb:cc:00:11:22*, *AABBCC001122*). VLANs, IP addresses and MAC addresses come first in the results. Only the tenants you have access to are searched. #### One click further - A port result opens its device, a cable result opens its trace. - A VLAN result opens the [network plan](https://docs.racktrace.io/network/network-plan) with the ports that carry that VLAN. Open one to go to its device, or press **Trace** to follow its cable. - An IP address result opens its device. Next to it are **VLAN**, the VLAN that holds the address, **Port & trace**, the switch port where a discovery source sees the device, and **IP plan**, the [IP addresses](https://docs.racktrace.io/network/ip-addresses#ipam) tab filtered on that address. - On the VLAN list, the subnet opens the IP addresses tab filtered on that subnet, and the **Ports** count shows the ports. On the IP addresses tab, the VLAN number of a subnet opens its ports. A long list shows **Only the first N are shown** (and a **+** after the count): type more of the address, name or subnet to narrow it down. A link to a VLAN or an address of another tenant switches to that tenant first. Search for one ID at a time (*RK001*, not *HQ/00/SL/RK001*). --- ## Export and reports > CSV files, a full JSON backup of a tenant, importing a tenant, and the printable report. URL: https://docs.racktrace.io/features/export Take the documentation with you: as spreadsheets, as a full backup, or as a printable report for a customer. ### Export and reports Open **Library & reports → Export & reports**: ![The Export & reports page](https://docs.racktrace.io/assets/screens/export.webp "Export & reports: the printable report, spreadsheets and a full backup.") - **Printable report**: choose **Everything** or a site, floor, room or rack and click **Open report** (see [The printable report](https://docs.racktrace.io/features/export#report)). - **Spreadsheets (CSV)**: **Devices**, **Cables** and **Ports**, for Excel, Numbers or Google Sheets. - **Full backup (JSON)**: everything in the tenant — sites, rooms, racks, devices, ports, cables and templates. **Download JSON** saves it. - **Import** (administrators): reads such a JSON file as a **new** tenant, for restoring a backup or moving data between servers. Optionally give the new tenant a name. - **Import from a spreadsheet** (administrators): the CSV files above, or an Excel list of your own, into this tenant — see [Importing from a spreadsheet](https://docs.racktrace.io/features/import-spreadsheets). - **Import from NetBox** (administrators): sites, locations, racks, devices, ports and cables of NetBox 3 or 4, through its API or from files — see [NetBox](https://docs.racktrace.io/integrations/netbox). Exports and the printable report need the Export right. The VLAN plan and the switch port list are exported from the [network plan](https://docs.racktrace.io/network/network-plan#np-csv). ### The printable report The report is client-ready documentation. You choose what it covers and what goes in it, so you print what you need — one server room on one sheet, for example, instead of the whole tenant. 1. Open it from **Export & reports**, with **Report** on a site, floor or room page, or with **Printable report** in the rack editor (that rack) or the row view (that room). 2. At the top, under **For**, choose what to print: everything, a site, a floor, a room or one rack. 3. Under **Show**, tick what goes in it: - **Summary**: the number of racks, devices, cables and trunks. - **Floor plans**: per floor the whole plan with rooms, racks, outlets and cable routes. - **Racks**: per room all racks side by side on one sheet, with everything mounted in them, seen from the front. A device mounted on the other side is shown dashed; 0U devices are named under the rack. Next to the tick choose how: **as a diagram** (each device a labelled block) or **as they will look** (the real cabinets with the equipment in them, as in the [picture of a rack](https://docs.racktrace.io/features/rack-cabinets#picture)). - **Rear side**: the racks seen from the rear as well. - **Device lists**: per rack a table with U, ID, name, category, model, management IP, serial and status. - **Devices outside racks**: the floor boxes, access points and other devices in the room. - **Cables between racks**: per room its racks on the floor plan, with every trunk (or bundle of cables between two devices) as a numbered arc from rack to rack, and a table with the same numbers: the racks, the trunk, the ports at both ends, the number of cables, the type and the length. A bundle to a rack elsewhere is an arrow with where it goes. Next to the tick choose how: **on the floor plan**, **as a sketch** (the racks in a row with the same arcs, without the floor plan) or **in a table only**. When not all racks of the room are on the floor plan, you get the sketch. - **Cable list**: every cable with its label, trunk, type, length and both ends. 4. Choose the **Paper**: A4 or A3, landscape or portrait. The drawings are scaled to the paper; when the floor plan and the racks fit side by side readably — a room with a few racks — they share one sheet. 5. Click **Print**, and choose **Save as PDF** in the print dialog to get a PDF. The choices are kept in the address, so a bookmark or a link opens the same report. Without choices a room gets the summary and its racks; a rack also its rear side and device list; a site or floor also the floor plans. The choices themselves are not printed. --- ## Share links > Send someone a link to look at a floor, room or rack without signing in — read only, for at most 30 days. URL: https://docs.racktrace.io/features/share-links Send an installer, a supplier or a colleague without an account a link to one floor, room or rack. They open it in any browser, without signing in, and see the place as it is documented now — read only, until the link expires or you withdraw it. ### Making a link 1. Open the place you want to share: - a **floor**: **Share** at the top of the floor page; - a **room**: **Share** at the top of the room page, or **Share a read-only link** in the row view; - a **rack**: **Share a read-only link** under *Rack* in the rack editor. 2. Choose how long it is **Valid for**: 1 day, 3 days, 1 week (the default), 2 weeks or 30 days. 30 days is the longest; after that the link stops working by itself. 3. Fill in **Shared with** (optional), e.g. *installer Jansen*. Only you and your colleagues see it, to recognise the link later. 4. Tick **Include network details** only when the receiver needs them (see [What the receiver sees](https://docs.racktrace.io/features/share-links#what)). 5. Click **Create link**. The address is copied; send it by e-mail or chat. ![The Share dialog of a room](https://docs.racktrace.io/assets/screens/share.webp "Share a read-only link: valid for, shared with, network details, and the open links of the room.") Only **editors and administrators** with the Export right on the tenant make, see and withdraw links (see [Roles and rights](https://docs.racktrace.io/administration/users-and-groups#roles)). A **viewer never can** — also not with the Export right through a group — and does not see the buttons. Every link is in the history of the place: *Shared*, with until when, for whom and whether network details are included. ### What the receiver sees The link opens a page of its own with your logo, **Read only** and until when it works. It shows the place as it is now: what you change is visible at once. ![A shared room as the receiver sees it](https://docs.racktrace.io/assets/screens/share-view.webp "A shared room: its racks and the links between them, read only — click a rack or a device to open it.") | Shared | The receiver sees | |---|---| | A floor | The floor plan and its rooms; from there every room, rack and device on the floor | | A room | Its racks — as a diagram or **As it looks**: side by side with the cable tray and the cables between them — the links between them, the devices outside racks and the room on the floor plan; from there its racks and devices | | A rack | The rack from the front and the rear — as a diagram or **As it looks** — and its devices | A device shows its ports, the cable on each port, what it is connected to and where it ends up (through patch panels and outlets). A cable that leaves the shared place shows where it goes, but that place cannot be opened. Without **Include network details** the receiver sees what is where: racks, devices, models, ports, cables and labels. With it also IP and MAC addresses, VLANs, serial numbers and asset tags, notes, the site address and online / offline. Passwords and keys of integrations are never shared, nor the history, users or anything else of the tenant. > **Note** > > Anyone who has the link can open it — it works like a key. Send it only to whom it is meant for, keep it as short as needed, and withdraw it when the work is done. ### Open links and withdrawing - The **Share** dialog lists the open links of that place: for whom, until when, by whom, and how often it was opened. - **Library & reports → Export & reports → Share links** lists every open link of the tenant. - **Copy** copies the address again; **Withdraw** stops the link at once, also for someone who has it open. Withdrawing is in the history (*Unshared*). An expired link is no longer listed. Someone who opens a withdrawn or expired link gets a page that says so; make a new link if they still need it. ### The live demo on racktrace.io **View a demo rack** on [racktrace.io](https://racktrace.io/live-demo) opens a share link of RackTrace's own demo organization: the same read-only page as above, with a fully cabled example customer and a bar with **Start free trial**. It is the only kind of link that does not expire, and only that one organization can make it (*Valid for → Does not expire (live demo)*). Links of your organization always end, after 30 days at most. --- ## Importing racks and cabling from a drawing > Bring existing rack drawings and network diagrams from draw.io, Visio or Lucidchart into RackTrace, check what was found and import it in one go. URL: https://docs.racktrace.io/features/import-drawings Already have your racks and cabling in draw.io, Visio or Lucidchart? Import the drawing instead of building everything again. RackTrace reads the racks, the devices in them and the lines between the devices, shows what it found, and makes it all at once after you have checked it. ### Which files | Tool | File | |---|---| | draw.io / diagrams.net | The `.drawio` file, also `.xml` and `.drawio.svg`. Compressed pages are fine. | | Visio | A `.vsdx` drawing. An old `.vsd`: open it in Visio and save it as `.vsdx` first. | | Lucidchart | **File › Export › Visio (VSDX)**, and import that file. | | Other tools | Gliffy, OmniGraffle and others: open or export the drawing in draw.io or as Visio. | A PDF or a picture has no shapes to read: import the original drawing. ### Importing 1. Open the room the racks go to and click **Import from a drawing** (under **Racks**). 2. Choose the file, or drop it on the dialog. 3. Check what was found (see below) and change what is not right. 4. Click **Import**. Everything is made in one go: when something cannot be made, nothing is, and the dialog says what and why. After the import, **Open in the rack editor** opens the first rack, and **Undo import** removes the racks and devices of this import again, with their cables. ### What is found - **Racks**: the rack shapes of draw.io (*More shapes › Networking › Rack*) and Visio, or a tall shape with “rack” or “cabinet” in its name. Their height in U comes from the drawing; text such as `42U` or `42 HE` in the rack sets it. - **Devices in a rack**: what is drawn in the rack, at the height where it is drawn. Its **category** comes from the shape (patch panel, switch, server …), its text or an ID such as `SW01`, `PP-A` or `FW1`. Shape data such as serial number, asset number and IP address come along. - **Devices outside the racks**: only the shapes a line goes to, such as wall outlets, floor boxes and PCs. A cloud or “Internet” is left out unless you tick it. - **Cables**: every line glued to a device at both ends. A line with a loose end, or one that is not glued, is listed under **Not imported from the drawing**. - **Names**: the first line of a text is the ID when it looks like one (`SW01`), the rest the name. A line with a model number (`Cisco C9300-48P`) is used to find the template, not as the name. A text beside the rack at the height of a device names that device. ### Checking and changing The dialog has three parts: - **Racks**: per rack its drawing with the devices at their U, and **ID**, **Name**, **Height** and **Room**. Untick a rack to leave it out, with its devices. Click a device in the drawing to find it in the list. - **Devices**: per device where it goes, **ID**, **Name** and **Template**. RackTrace suggests the template of the [device library](https://docs.racktrace.io/features/device-library) whose model or part number is in the text (such as `C9300-48P`), and otherwise a generic one of the right kind, height and number of ports. **Another template…** chooses any template; **No template (own ports)** makes the device with the number of ports in **Ports**. A device that clashes with another one in the rack goes to the first free U. - **Cables**: per cable both ends with their port. Click a port to choose another one. **Label** and **Type** can be changed. With more than one page, the pages are shown at the top: untick the ones you don't want, such as a back view of the same rack. **Devices outside the racks go to** sets the room for outlets and endpoints. The IDs must be valid (letters, digits and `. _ - + #`). An ID that already exists in the room or rack gets `-2`, `-3` … ### Ports - **Written at the line**: a label at an end of the line (draw.io), or text on the line such as `Gi1/0/24 – 12`, `24 <-> 12` or `X1 → F01`. `Gi1/0/24` finds port `Gi1-0-24` or `24`; `(R)` or `rear` after it means the rear of a pass-through port. - **A drawn port**: a line glued to a small shape with a number inside a device goes to that port. - **Otherwise**: the first free port of the right kind — fibre for a fibre cable, copper otherwise. Ports named in the drawing go first. - **Patch panels and outlets**: a line to another patch panel or outlet elsewhere is building cabling and goes to the rear; a line to a switch, server or PC goes to the front. See [Pass-through ports](https://docs.racktrace.io/concepts/ports-and-cables#pass-through). A cable without a free port is shown in red and is not imported; choose a port, or a template with more ports. ### Cable details - **Type**: from the text of the line (`Cat6a`, `OM4`, `OS2`, `DAC` …), otherwise what fits the port, as in the rack editor. - **Colour**: the colour of the line, as the nearest [cable colour](https://docs.racktrace.io/concepts/ports-and-cables#cable-details). A black or grey line gets the usual colour for its type. - **Label**: text such as `C-0042` on the line; otherwise the next free label. - **Planned**: a dashed line becomes a planned cable. - Other text on the line is kept in the cable's notes. ### History Every rack, device and cable gets its own entry in the [history](https://docs.racktrace.io/features/history-and-search), as when you make it by hand. The room gets one more entry that says what was imported from which file. Importing needs the right to change the documentation; cables also need the Cables right. --- ## Importing devices, cables and ports from a spreadsheet > Fill a tenant from CSV files or an Excel workbook — the CSV exports of RackTrace or an inventory list of your own — with a preview of what is created and why rows are skipped. URL: https://docs.racktrace.io/features/import-spreadsheets Have an inventory in Excel, or CSV exports from another RackTrace? Import them into a tenant instead of typing everything again. RackTrace reads devices, cables and ports, places the devices in their site, floor, room and rack, picks the templates from the device library, and shows you what it will create before anything is saved. ### Importing 1. Open **Library & reports → Export & reports** of the tenant and click **Import CSV / Excel…** under **Import from a spreadsheet** (administrators). 2. Choose one or more files, or drop them on the dialog: CSV files, or one Excel workbook (`.xlsx`) with a sheet per kind. 3. Check the preview (see below). Change how a column is read, or leave a file out, and the preview follows. 4. Click **Import**. The rows that can be imported are made in one go; rows with an error are left out. Importing the same files again only adds what is new: everything that is already there is skipped. ### Which files - **The CSV exports of RackTrace**: **Devices**, **Cables** and **Ports** under **Spreadsheets (CSV)**, and **Export cables** of one rack. What you export can be imported again — into another tenant, or into the same one after a change in Excel. - **A list of your own**: start from a template (**Templates for Excel** on the card or in the dialog: **Devices**, **Cables**, **Ports**). They open in Excel in Dutch or English: the columns are separated by `;` and the file is UTF-8, so `é` and `€` stay intact. Replace the example rows with your own. - **Excel**: save as **CSV UTF-8**, **CSV (separated by semicolons)** or keep the `.xlsx`. Columns separated by `;`, `,` or a tab are all read, and so are files without UTF-8 (Windows) or as *Unicode text*. An old `.xls`: save it as `.xlsx` or CSV first. - Several files at once — say the three exports — or one workbook. A title above the column names is fine; a sheet that holds none of the three kinds is left out. The kind of each file (devices, cables or ports) follows from its columns. Column names of the export are read, and common other names too: *Name*, *Hostname*, *Vendor*, *Serial number*, *IP address*, and Dutch ones such as *Locatie*, *Naam*, *Fabrikant*, *Serienummer*. ### Devices Where a device goes, one of three ways: | Column | Example | | |---|---|---| | **Location** | `HQ/28/SL/RK001_M` | site/floor/room/rack — or site/floor/room for a device outside a rack (an outlet, an access point) | | **ID** (as exported) | `HQ/28/SL/RK001_M/SW01` | the location with the device's own ID at the end | | **Site**, **Floor**, **Room**, **Rack** | `HQ`, `28`, `Server room`, `RK001_M` | an ID or a name each; without a floor, the site's only floor | - A site, floor, room or rack that does not exist yet is made — with the names from the **Site**, **Room** and **Rack** columns when the location only has IDs. A new rack is 42U, or higher when a device in it sits higher. - **Manufacturer** and **Model** pick the template from the [device library](https://docs.racktrace.io/features/device-library): the model name or the part number (`USW-Pro-48` and `UniFi Pro 48 (USW-Pro-48)` both work), the tenant's own templates first. The device then gets the ports, height and front of the template. Without a template it is made as the row says, with the ports its cables and the ports sheet name. - **U** is the bottom unit in the rack; without one the device takes the highest free place. **Code** is its ID (`SW01`); without one it is made from the name. - Also read: **Name**, **Height (U)**, **Face** (front / rear), **Category**, **Status**, **Serial**, **Asset tag**, **Management IP**, **MAC**, **Network** and **Notes**. - **Skipped**: a device with the same ID in the same place (without an ID: the same name), or with a serial number that is already in the tenant. ### Cables - **A-end** and **B-end** are the paths of the two ports, as in the export: `HQ/28/SL/RK001_M/SW01/24`. The rear of a patch panel port ends in ` (R)`: `HQ/28/SL/RK001_M/PP01/01 (R)`; the two ends of a PATCHBOX cassette in `↑` and `↓`. Instead of a path, an **A device** and an **A port** column (and B) work too. - Also read: **Label**, **Trunk** (made when there is none by that label), **Status** (`planned` draws it dashed), **Type** (`Cat6a`, `OM4` …), **Color** and **Length (m)** — `0,5` and `0.5` both work. - A port that already has another cable is an error; a cable between two ports that are already connected to each other is skipped. ### Ports - **Port** is the port's path, as in the export; or a **Device** column with the device's path and the port's name in **Port**. - The ports of a device the import makes get the **Label**, **VLAN**, **Speed**, **PoE**, **PoE setting**, **Switched off**, **Link aggregation**, **Role** and **Type** of their row. A port the device does not have yet is added (`01 (R)` adds a pass-through port: front and rear). - Ports of devices that were there already are not changed; a port they do not have yet is added. - **Connected to** (and **Cable** for its label) makes the cable to that port when the cables file has not made it. ### The preview - **Files**: per file (or sheet) what it holds, the separator and encoding, and per column how it is read, with the first row as an example. Choose another kind, another meaning for a column, or **— not imported —**. - **What will be created**: the new sites, floors, rooms and racks with their IDs, and the number of devices, ports, cables and trunks. - **Devices**: every device that will be made, with its ID and the template it gets. - **Skipped and errors**: per file and row why it is skipped (already there, in the file twice) or cannot be imported (a taken U, a location that is not a place, a port that does not exist), and notes such as an unknown category. The preview is the import itself, undone at the end: it says exactly what **Import** will do. ### Rights, history and plan - Importing is for administrators, as is the [JSON import](https://docs.racktrace.io/features/export#export). Anyone signed in can download the templates. - Every site, floor, room, rack, device and cable made has its own entry in the [history](https://docs.racktrace.io/features/history-and-search), and the tenant one more with the files and what came in. - When the plan of your organization limits racks or devices, an import that would go over it is refused as a whole; the preview says so first. --- ## Onboarding a tenant > The steps that make a new tenant usable, worked out from the data, and a list of what is still missing — each line with a button to where you solve it. URL: https://docs.racktrace.io/network/onboarding **Onboarding** shows what a new tenant still needs before it is usable: the steps, how far each one is, and a list of what is missing. RackTrace works it all out from the documentation and from what discovery sees — there is nothing to tick off. Open it from the menu (**Network → Onboarding**) or from the card on the dashboard. ### The steps | Step | Required | Done when | |---|---|---| | **Location** | yes | The tenant has a site with a room. | | **Discovery source** | yes | A UniFi site, Meraki network, FortiGate, scanner or JSON source is linked to the tenant. | | **First discovery** | yes | The source synced and saw network devices. | | **Core devices linked** | yes | Every switch, router, gateway, firewall and access point discovery sees is linked to a documented device. | | **Uplinks cabled** | yes | Every uplink port of a linked device has a documented cable. | | **VLANs documented** | yes | Every VLAN in the network configuration a source reports is in the network plan. | | **Racks** | no | Every documented switch, router, gateway and firewall is in a rack. | | **Monitoring and notifications** | no | Monitoring is on, something is monitored, and a notification policy that is switched on mails when an alert opens. | A step can also say **Cannot be checked**: the sources do not report what it needs — no uplinks, or no network configuration. That is not the same as missing; it does not hold the tenant back. When every required step is done, the page becomes **Documentation health**: the same overview, for when the network changes later. ### Core devices linked The bar at the top shows which part of the core devices is linked, with the goal of **80%** marked on it. Core devices are the switches, routers, gateways, firewalls and access points discovery sees. - A device reported by two sources (the same MAC address, or linked to the same documented device) counts once. - A device you **ignore** under Discovery, or that the source no longer reports, does not count. - Servers, NAS devices and other infrastructure do not count. ### What is missing Per kind, with a button on every line: - **Core devices not linked** — **Link** opens [Discovery](https://docs.racktrace.io/integrations/discovery#devices) on the devices that are not linked. - **Uplinks without a documented cable** — with the neighbour discovery sees on the other end (LLDP). **Connect cable** opens the device. A cable that is only planned does not count: it is not there yet. - **VLANs seen but not documented** — the networks a source configures that are not in the network plan: the same list as the [review in the network plan](https://docs.racktrace.io/network/unifi-review), where **Review** takes you to take them over. A VLAN that is only seen on a port (the native VLAN 1 that most switches report on every port, for example) does not count. - **VLANs documented but not seen** — in the plan, but no source configures them: perhaps they are no longer in use. The review proposes to remove them; they do not hold the step back. - **Network devices without a rack** — access points are left out: they hang on a wall or a ceiling. A list shows at most 100 lines, with the total next to its title. ### Discovery sources Per linked source the last sync, how many network devices and clients it sees, and how fresh its last report is, with the label of the device page: **Observed … ago** while fresh, **old** once it is older than the threshold of its kind of source (6 hours, see [Source and freshness](https://docs.racktrace.io/concepts/source-and-freshness#thresholds)) — what it says may no longer be true — and **Not observed yet** when it never reported. This used to be 24 hours on this page; it is now the same threshold everywhere. **sync failed** shows the error of the last sync. ### Who sees what Everyone with access to the tenant sees its onboarding. The buttons open the pages where the work is done, and those pages ask for the usual rights: linking a source is for administrators, linking devices and cabling need the right to change the documentation, VLANs the right to change the network plan, notification policies the right to change monitoring. --- ## Network plan > VLANs with their IP plan, port profiles on switch ports, the VLANs of one port, the route check and CSV exports. URL: https://docs.racktrace.io/network/network-plan The network plan documents the logical network next to the physical one: VLANs with their IP plan, port profiles on switch ports, routing, WAN, VPN, WiFi, the firewall, port forwards and DHCP reservations. With a UniFi site linked, RackTrace reads all of this from the console. ### The network plan page Open **Network → Network plan** in the side menu. The page has these tabs: ![The network plan with VLANs and port profiles](https://docs.racktrace.io/assets/screens/network-plan.webp "The network plan: VLANs with their IP plan, port profiles and the route check.") | Tab | What it holds | |---|---| | VLANs & profiles | The **Networks** card, a network filter, **VLANs**, **Port profiles** and the **Route check** | | IP addresses | Used and free addresses per subnet, conflicts, and **IP assignments** | | Routing | **Static routes**, and the live routing table from UniFi | | WAN & VPN | **WAN connections** and **VPNs** | | WiFi | **WiFi networks** | | Firewall | **Firewall zones** and **Firewall rules** | | Port forwards | **Port forwards** | | DHCP reservations | **DHCP reservations** | | From UniFi | The differences with what UniFi reports (only with a linked UniFi site) | | Security alerts | Changes that can open up the network | A dot on a tab means it has differences with UniFi. At the top, **VLANs (CSV)** and **Switch ports (CSV)** export the plan (see [CSV exports](https://docs.racktrace.io/network/network-plan#np-csv)). ### VLANs 1. Click **New VLAN**. 2. Fill in the **VLAN ID** (1–4094) and **Name**, and the **Network** if you use networks. 3. Choose a **Colour**. It is used for ports and cables everywhere. 4. Fill in the IP plan: **Subnet** (e.g. 10.0.20.0/24), **Gateway IP**, **DHCP** (a range such as 10.0.20.50 – 10.0.20.250, or relay), **DNS servers (DHCP)** and **Domain name**. 5. Choose the **Gateway device**, and in the second box its HA partner (the other firewall of an HA pair, or the UniFi Shadow Mode gateway). The route check and the simulation use it. 6. Optionally fill in **Purpose** (workstations, voice, OT, management …) and **Notes**, then click **Save**. The **VLANs** table shows each VLAN with its network, subnet, gateway, DHCP and the number of untagged and tagged ports. Deleting a VLAN removes it from port profiles and ports too. ### Importing VLANs and profiles from UniFi files Without a linked UniFi site you can import the configuration from two JSON files. 1. Sign in to UniFi Network and open `https:///proxy/network/api/s/default/rest/networkconf` (networks) and `…/rest/portconf` (port profiles). Save each page with `Ctrl`+`S`. On a self-hosted controller: `https://:8443/api/s/default/rest/…`. Replace `default` with your site name if needed. 2. Click **Import from UniFi** on the network plan. 3. Choose **networkconf.json** and, optionally, **portconf.json**. With networks, choose the **Network of this UniFi environment**. 4. Click **Import**. Existing VLANs and profiles with the same ID or name are updated; WAN, VPN and disabled networks are skipped. ### Port profiles A port profile is the VLAN set-up of a switch port: one untagged (native) VLAN plus tagged VLANs, as in UniFi. Typical profiles: *Workstation* (untagged workstations + tagged voice), *AP* (management + tagged SSID VLANs) and *Uplink* (all VLANs). 1. Click **New profile** (available once there are VLANs). 2. Fill in the **Name** and **Network**, and choose the **Untagged (native) VLAN**. 3. Under **Tagged VLANs**, choose **None (access port)**, **Selected VLANs** (tick them) or **All VLANs (trunk / uplink)**. 4. Optionally set **PoE**, **Colour** and **Notes**, then click **Save**. #### Giving many ports a profile 1. In the rack editor, select the switch and choose **Tools → Port profiles (VLANs)…**. Or click **Port profiles** on its device page. 2. Use the top row for a range: **Ports** from … to …, **all**, **odd only** or **even only**, the profile, then **Apply to range**. Or pick a profile per port. 3. Click **Save**. In the rack editor this can be undone. ### Setting VLANs on one switch port Select the port in the rack editor, or open it on the device page, and click **VLANs…**. The dialog has two tabs: - **Port profile**: pick a profile, or **— none —**. - **Own VLANs**: add VLANs with **+ Add VLAN…** and choose per VLAN **Untagged** (one per port), **Tagged** or **Block** (never carried). For a trunk, tick **All others tagged (trunk)**: every VLAN of the network is tagged, except the untagged and blocked ones. The summary line says what the port carries and which colour its cables get. Click **Save**. Ports with their own VLANs keep them until you choose a profile for them. Patch panels, outlets, PDUs, UPSs and power, console, USB and video ports have no VLANs. ### Route check The **Route check** card runs by itself when you open the network plan; **Check again** runs it once more. It follows the links between switches, gateways, firewalls and routers, also through patch panels and PATCHBOXes, and reports: - **errors**: a VLAN of one network on a port of another network, or a VLAN on an access port that doesn't reach its gateway (no uplink, no uplink that carries the VLAN all the way, or uplinks without a profile or VLANs); - **warnings**: links between switches without a profile or VLANs, native VLAN mismatches, and an HA pair where a VLAN reaches only one of the two gateways; - **notes**: a VLAN blocked on one side but sent by the other, or a VLAN in use without a gateway (set its **Gateway device**). Each line has an **open** link to the device. When everything is fine, the card says that every VLAN on an access port reaches its gateway and the networks are kept apart. ### CSV exports and the migration list - **VLANs (CSV)**: every VLAN with network, subnet, gateway, gateway device, DHCP, purpose and notes. - **Switch ports (CSV)**: every port of switches, gateways, firewalls and routers with profile, native, tagged and blocked VLANs, PoE, label, the patch panel or outlet it runs through and the end device. Useful as a migration list. - **CSV** on each card of the other tabs exports that card. The two buttons at the top need the Export right. Changing anything on the network plan needs the Network plan right; without it you can still view everything and run the route check. --- ## IP addresses > Used and free addresses per subnet, the next free address, and address conflicts. URL: https://docs.racktrace.io/network/ip-addresses The **IP addresses** tab of the network plan shows what is in use in every subnet, what is free and what conflicts. ### Addresses per subnet The **IP addresses** tab shows per VLAN subnet which addresses are in use, according to RackTrace (management IPs, IP assignments, DHCP reservations, gateways) and UniFi (devices and clients), what is free and what conflicts. Search with **Search IP, name or MAC…**. ![The IP addresses tab of the network plan](https://docs.racktrace.io/assets/screens/ip-addresses.webp "Used and free addresses per subnet, with the next free address and the conflicts.") - Each subnet shows a usage bar with the DHCP range, the number in use and free, and **next free**: the first free address outside the DHCP range. Click it to copy. - Inside, a table lists every address with its name, MAC and where it is known from, and **Free:** lists the free ranges. - **Not in a subnet of the plan** lists addresses outside every documented subnet. - **IP assignments** documents extra addresses (static, virtual, reserved) with **New IP assignment**. Conflicts it finds: - two devices on one address; - the network, broadcast or gateway address in use; - a fixed address inside the DHCP range without a reservation; - a device that UniFi sees on another address than documented. **Free IP** next to every management IP field (a **+** in the rack editor) opens **Next free IP address**: click a VLAN to fill in its first free address. This only works for VLANs with a subnet. --- ## Network monitoring > Every network device discovery finds is monitored automatically, on one screen with a live map. URL: https://docs.racktrace.io/network/monitoring RackTrace monitors every network device that discovery finds — switches, routers, firewalls, gateways and access points — without anyone making a check. Open **Monitoring** for the workspace of the tenant: the network map in the middle, the chosen device in detail beside it and the alerts below, on one screen. ### What is monitored A device is monitored because a discovery source reports it: a UniFi site, Meraki network, FortiGate, Auvik tenant or JSON feed linked to the tenant, or a scanner of the tenant. Monitoring starts at the next sync; nothing has to be set up. - **Which devices**: switches, routers, firewalls, gateways and access points. Servers, printers and cameras are not monitored (yet). A device you **ignore** under Discovery is not monitored either. - **One device, several sources**: a switch that UniFi and the scanner both report is one monitored device. Rows of several sources join when they are linked to the same documented device or report the same MAC address. Our own scanner measures it; the controller fills in (see [Scanner first](https://docs.racktrace.io/network/monitoring#scanner-first)). - **Leaving**: a device a controller no longer lists, or one the scanner has not reached for 30 days, is no longer monitored. Its history and incidents stay; when it comes back, it is the same monitored device again. - **Another tenant**: a scope that is linked to another tenant (or to none) takes its monitoring with it at once. - **Limits**: at most 500 monitored devices per tenant (routers first, then switches, then access points) and 64 watched ports per device. The workspace says when a tenant reaches a limit. - **Your plan**: on racktrace.io your plan sets how many devices are monitored, in all tenants together (Team 100, MSP 1,000, Enterprise as agreed). A device that is monitored stays monitored, also when the plan's number is lowered. Above the number, a new device is documented but not monitored: the workspace says **N devices not monitored — plan limit of your plan**. When there is room again, the next discovery sync monitors them: routers first, then switches, then access points, then the device found first. From 80% of the number, the workspace warns administrators. Switching monitoring on for a tenant while every place is in use is refused. Your usage is under **Administration → Billing**. Switch monitoring off for a tenant under **Monitoring → Settings**. Nothing of that tenant is then measured, and its open alerts are closed without a mail. ### How a device is measured - **By a controller** (UniFi, Meraki, FortiGate, Auvik, a JSON feed): what it reports is the measurement — online or offline, and every port up or down. That comes with every sync. UniFi and Meraki are also asked for the state of their devices every 2 minutes between their syncs (one call per account or organization), so an offline device is noticed within minutes. A device the controller has as offline gives no port measurement: its ports are as they were. - **By the scanner** (SNMP): every minute, one SNMP read per device of its system and its whole interface table (status, speed, traffic, errors and discards; at most 512 interfaces), and its uptime. Agent **1.7.2** or newer also reads when each interface last changed state and its duplex. A device that does not answer SNMP is pinged: if it answers, it is up and its SNMP problem is shown; if not, it is down. The interfaces need RackTrace Agent **1.4.0** or newer; with an older agent the device is **unknown**, with that reason. In the same SNMP read, every 5 minutes, agent **1.5.0** or newer also reads the device's health and the tenant's custom OIDs (see [Load, errors and health](https://docs.racktrace.io/network/monitoring#health)). - **By the scanner, by ping and SSH** (agent **1.8.0** or newer): a network device without SNMP that the scanner [reads over SSH](https://docs.racktrace.io/network/monitoring#ssh) — say a switch the UniFi controller knows — is pinged every minute: up or down. Its interfaces, neighbours and VLANs come from SSH, every few hours; its ports are not watched every minute. SNMP credentials are those set under [Credentials](https://docs.racktrace.io/network/monitoring#credentials), or those of the tenant's SNMP scan: they are encrypted in RackTrace and only sent to that scanner — from agent 1.7.0 sealed for its own key. Prefer SNMPv3 with authentication and AES privacy, read-only. ### Scanner first, integrations fill in Monitoring starts from your own scanner. Integrations that need a login (UniFi, Meraki, FortiGate, Auvik, [NetBird](https://docs.racktrace.io/integrations/netbird), a JSON feed) add what the scanner cannot see. They never get the scanner's [credentials](https://docs.racktrace.io/network/monitoring#credentials). - **The scanner measures** every device it reads over SNMP: status, interfaces and health, every minute, from the customer's own network. A device that UniFi and the scanner both see is measured by the scanner. - **The integration measures what the scanner cannot**: a site without a scanner, a tenant without a scanner, and a device that gives no SNMP — most UniFi equipment by default, which the scanner only sees as a host on the network. Nothing changes for a tenant without a scanner. Once the scanner [reads such a device over SSH](https://docs.racktrace.io/network/monitoring#ssh), the scanner measures it after all (by ping): the order is SNMP, then SSH, then the integration. - **What the integration still adds** while the scanner measures: the links it reports (uplinks, LLDP) for the map and the watched ports, the documented cables found through its ports, and its own state of the device (online, offline, or another state such as upgrading). That state is shown in the device panel under **Also reported by** and on the incident page. Discovery keeps everything else it reports (clients, PoE, firmware). - **When they disagree, the scanner decides.** If the scanner cannot reach a switch that UniFi reports online, the switch is down and gets an alert. It works the same the other way round: a device the scanner reaches is up, even when the controller has it offline. Either way, the device panel and the incident page show what the other source reports. The scanner sees the network as the customer's own devices do, while a controller can still hear a device over another path or report late. - **The source does not switch during an outage.** The scanner only takes a device over when its last scan reached it. A device the scanner does not reach while UniFi has it online stays with UniFi. A device the scanner already measures stays with the scanner when a scan no longer reaches it: it is down by the scanner's own measurement. - **When the scanner takes over** (a scanner is added, or this order came into use): the device stays the same monitored device, with its history. An open alert goes along. If the scanner sees the failure too, it stays one alert, with no new mail. If the scanner finds the device or port up, the alert recovers. Whoever had the open mail gets the recovery mail, and it gives the reason: *measurement handed over to the scanner, which sees it up*. A watched port, site or alert that has no counterpart under the new measurement (an uplink the scanner does not see, a site that two scanners now cover, a load alert the controller cannot measure) is closed: its recovery mail says it is no longer watched this way, and why. Each alert gets one open mail and one recovery mail. The same happens the other way round when a scanner goes away. ### Watched ports Not every port is watched: a client port that goes down when someone shuts a laptop is no alert. Watched are: - the links between two monitored devices — from LLDP/CDP, the uplinks a controller reports, and documented cables between two network devices; one side per link (the side of the device that comes first in the topology); - a device's own uplinks that lead to no monitored device (the internet, an unmanaged switch). The device panel shows every interface; the watched ones come first, with what is behind them. ### Load, errors and health The scanner measures more than up or down: - **Load, errors and discards** of every interface, every minute, from its counters (64-bit where the device has them): traffic in and out, the share of the link speed, errors and discards in and out. Now as a number per second (as a switch shows them); in the charts and the thresholds per minute, the interval they are measured in. Every interface that is up gets a chart; only the [watched ports](https://docs.racktrace.io/network/monitoring#watched-ports) alert, so a client that fills its own port is no alert. - **Health** every 5 minutes: CPU, memory, temperature, fans, power supplies and the PoE budget. RackTrace reads the standard MIBs every vendor may have (HOST-RESOURCES, ENTITY-SENSOR, POWER-ETHERNET) and the vendor's own MIB for Cisco, HPE/Aruba, MikroTik and Fortinet. For fans, power supplies and temperatures the device's own judgement counts: a fan it reports failed, a sensor it reports too warm. What a device does not report is shown as **not reported by this device**, greyed, without a check or an alert: a switch without ENTITY-SENSOR has no temperature, not a temperature problem. A value that could not be read this time (a lost packet, a time-out) is **unknown**, never down: its check and an open alert stay, and it is read again the next round. A value the device reported before and then returns empty is **unknown** the first time; empty again at the next reading, it counts as not reported: its check goes and an open alert on it is closed without a mail (about 10 to 15 minutes after the first empty reading). It is asked again after 6 hours; when the device reports it again, the check comes back. UniFi devices give over SNMP what the standard MIBs give; their health through the UniFi controller comes later. RackTrace only reads from a device (GET, GETNEXT and GETBULK): the agent has no code that writes to a device. ### An interface in detail Choose an interface in the device panel for everything about that port: - **State and since when**: up, down or switched off, and since when according to the device itself (`ifLastChange`; "since the restart" when it has not changed since). **Speed and duplex** (full or half, from the EtherLike-MIB). Both need agent 1.7.2; with an older agent the device panel says "from scanner 1.7.2" instead. - **Traffic, errors and discards** in and out, now, and as charts over 24 hours, 7 or 30 days (load, errors, discards) with the thresholds of a watched port. Errors and discards are kept per direction only for a port that has any, so a healthy port costs nothing extra; before this version only their sum was kept, shown as *In + out*. - **VLANs**: the untagged VLAN (PVID) and the tagged ones. **Clients**: the MAC addresses in the port's MAC table (and LLDP neighbours that are no network device), with their IP address from the ARP table, their name and their vendor (from the MAC address) where known. A port towards another switch has no clients: its MAC table holds a whole network. - VLANs and clients come from [discovery](https://docs.racktrace.io/integrations/discovery), not from the minute's measurement: the device panel says from which scan and how long ago. Reading every MAC table every minute would cost thousands of rows per switch per minute. The list of interfaces shows the same in short: errors and discards per second, the VLANs and the number of clients. Per device the panel shows its **uptime** (`sysUpTime`) and its last **restarts**: an uptime that went back is a restart, marked in the strip of the last 24 hours and listed with how long the device had been up. The 32-bit uptime of SNMP starts again at zero after about 497 days without a restart; that is recognised and is no restart. A restart while the scanner could not reach the device is seen too: the device then started after the last measurement. The device's page shows its uptime and links to its interfaces. ### One failure, one alert | What | Alert | |---|---| | A device does not answer (3 measurements by the scanner, or the first report of a controller) | **Critical**, resolved after 2 good measurements | | A watched port is down while the devices on both ends still answer (4 measurements, or one report) | **Warning**: lost redundancy | | At least 80% of at least 3 devices of one site go offline at once | One **critical** alert for the site | RackTrace knows how the devices hang together (from LLDP, uplinks and documented cables) and uses that so one failure is one alert: - A device **behind** a device that is down gets no alert of its own: a switch fails, the access points behind it are shown hollow, as *unreachable behind* the switch. If one is still down once the switch is back, it gets its own alert then. - A port to a device that is down is no extra alert: a dead access point is one alert, not also the switch port it was on. - A site that goes dark (power, the line) is one alert for the site. - A scanner or controller that stops reporting makes its devices **unknown**, never down, and sends no mail. **Unknown** means RackTrace has no recent measurement or no trustworthy conclusion: nothing measured in three intervals, an agent that is too old, a controller that reports a state other than online or offline. It is never counted as downtime and never opens or closes an alert. ### The workspace **Monitoring** is one screen for the tenant chosen at the top, with the network map in the middle: - **Above the map**: the sites of the tenant as buttons, each with the colour of its worst device (the map shows one site; it starts with the one that needs most attention), the counts (up, warning, down, unknown, not monitored — click one for the list of those devices), how fresh each scanner is, and **Discovery** and **Settings**. Under it the layers **L1 Physical**, **L2 VLANs** and **L3 IP**, the switches **Load**, **End devices** and **Alerts**, and **Map | List**. - **The map**, laid out by itself as a tree from the routers: each network device a tile with the icon of its role, in the colour of its status (a red glow when it is down, dashed when it is behind a device that is down or not monitored), its name and model under it, and a red count of its open alerts. Each link as thick as its speed (an aggregated link thicker, with a line through it) and coloured by how full it is — green below 50%, orange from 50%, red from the tenant's load threshold (90% by default), with the percentage from 50% — red and dashed when it is down, dotted when it is inferred from a MAC table or a controller's uplink, blue and dashed when only a documented cable says so, faded when only an old report shows it. The ports appear on the links of the device or link you chose. Links come from LLDP / CDP — also when the neighbour was found by another scan job — from the uplinks a controller reports and the MAC tables, and from documented cables. Drag to move; scroll, pinch on a touchpad or use the buttons to zoom; the map keeps where you were per site while it refreshes. - **End devices**: per network device one closed bundle beside it that says what is behind it (**30 end devices · 20 PCs · 6 phones · 4 printers**; behind an access point its Wi-Fi clients per VLAN). A click opens it into a block of at most 24, with the port of each; the panel lists them all. A map carries at most 5,000 end devices and says how many it left out. - **L2 VLANs**: the same map with on each link what it carries — **U1 · T 10,20,30** (untagged 1, tagged 10, 20 and 30); **≠** when its two sides do not carry the same, **VLANs unknown** when no source reported them for that port (never "none"). Above the map a chip per VLAN of the site, with its name from the IP plan. Choose one to follow it: the links that carry it turn its colour, the rest and the devices without it dim, and each bundle counts only its members (**6 on VLAN 30**). Typing *vlan 30* in the search field does the same. The VLANs come from what the sources report per port (the scanner over SNMP or SSH, UniFi, Meraki, FortiSwitch); an end device is in its own VLAN, else in the untagged VLAN of its port. - **L3 IP**: another layout. The internet on top (over the WAN link or default route a source reports), the gateways under it, and under each gateway its subnets as blocks — name, CIDR, VLAN, gateway and the number of hosts — in the colour of their VLAN. A subnet the sources report and the IP plan has is a plain block; one only the IP plan has is dashed and says **not seen** (*documented, not seen*); one the plan lacks says **not in plan**. A gateway no source names — RackTrace takes the only router of the source that reports the subnet — is drawn dotted and called *inferred*, with why; it is never shown as a fact. Another site that a route or a VPN reaches is a block on the right with its state; click it for that site. A VPN is drawn only where a source reports one (a FortiGate, UniFi or Meraki site-to-site tunnel), dashed and *configured*: no source measures whether a tunnel is up. Click a subnet for its panel: its hosts with where each is connected (switch and port, or Wi-Fi behind an access point) and **Open in the IP plan**. - **Not on the map yet**: a device that no source places — no link is known — is never drawn loose. It is in this tray at the top right of the map, with one line why (*No LLDP read*, *Controller not linked*, *Only ping answers*, *Discovery no longer reports it* …). Click it: the tab **Sources** says per reason what was tried, what came back and what fixes it — enable LLDP, link the controller, add credentials and test them, link it to its documented device. The overview of the site says how complete the map is (**7 of 9 network devices placed**). - **The panel** on the right shows what you chose, without leaving the page. A device has six tabs: **Overview** (its open alerts, 24 hours of availability, its health as tiles with a chart each, what it is connected to, its end devices, its checks, where it is documented, its facts), **Interfaces** (the front of the device, one square per port — up, down, not in use, towards a network device, overloaded; click a port for its state, speed, VLANs, neighbour, documented cable, clients and charts — then the busiest and every interface), **Alerts** (its open alerts with who they are assigned to, **Acknowledge**, **Assign**, **Create ticket**, **Measure now** and the incident page, its last incidents, **Override for this device**, **Maintenance**), **Config** (the [configuration backup](https://docs.racktrace.io/network/monitoring#config-backup)), **Access** (how RackTrace logs in: [credentials](https://docs.racktrace.io/network/monitoring#credentials), **Test**, the SSH host key, **Fetch now**) and **Sources** (who measures it and how fresh, what each source gave in its last scan — SNMP, LLDP and CDP neighbours, the MAC table, what SSH read, a port it shares with another network device; for a UniFi device which API answered (the Network API, only the official API — which has no LLDP — or only Site Manager) with its LLDP lines, uplink and wired clients — what other sources report of it, and why it is not on the map). Its head has **Documentation**, **What if this fails** (the simulation), **Changes** (the change log of discovery), **Measure now** and **Maintenance**. A link shows both sides with their ports, speed, load, VLANs (each side when they differ, and who would report them when they are unknown), how it is known and how fresh; an end device its addresses, VLAN and the port it is behind. With nothing chosen, the panel is the overview of the site: the counts, what needs attention, how complete the map is, and every source with its freshness and its silence mails. - **The alerts** in the drawer below, of every site of the tenant, the shown site first and newest first: severity, device, what, since when, state and who it is assigned to, **Acknowledge**, **Assign**, **Ticket**, **Show on map** (chooses the device and opens the tab of what the alert is about, a port on its port) and the incident page. Filter by site, by severity and by state — *Open*, *Acknowledged*, *Assigned to me* or *Resolved* (the alerts of the past); the filters are in the address too. Tick alerts (or all shown) to **Acknowledge** or **Assign** them at once. Fold the drawer to one line with the counts; on a laptop screen it starts folded. It lists up to 500 alerts and says when there are more. - **Assign** an alert to someone who takes care of it: everyone with access to the tenant can be chosen, and it is noted in the history (nobody gets a mail about it). **Ticket** makes a ticket in the [ticket system](https://docs.racktrace.io/integrations/ticket-systems) with the alert, the link to it and its device (else its site) in it, the priority from the severity; you edit it before it is sent. It takes the tickets right and a tenant linked to a client. - **Search**: the field in the top bar (**Ctrl K**). On this page it searches the map while you type — by name, IP or MAC address (any notation), vendor or model, a kind (*printers*, *access point*), or *vlan 30* (which also follows VLAN 30 on L2) — marks what it found, dims the rest and opens only the bundles with a match; the list under the field groups the network devices and end devices it found on this map (an end device with its switch and port, or *Wi-Fi* and its access point), those on the other sites, and those of the **other tenants** you have access to — monitored devices and end devices by name, IP or MAC address, vendor or kind. A hit in another tenant opens that tenant, its site and the device or end device on the map. **Enter** takes the first. At most 25 devices and 50 end devices are listed per search; type more to narrow it down. Elsewhere it searches the documentation as before, and lists **Monitored devices** and **End devices** of every tenant you have access to, each opened on the map of its tenant. - **List** instead of the map: every device of the site with its status and why, role, address, model, source, whether it is on the map and when it was measured; filter by status or source, and the search field filters it too. Everything you chose is in the address (`#/monitoring?t=…&site=…&layer=l2&vlan=30&sel=…&tab=interfaces&port=…&asite=…&asev=critical&astate=mine`, on L3 `layer=l3&subnet=…`): a link in a mail or a ticket opens the same view, and a reload keeps it. The older `#/monitoring?device=` still works. The page refreshes itself every 30 seconds. The side menu folds into a rail of icons with the button at its bottom: the workspaces (this page and the rack and floor plan editors) start folded, other pages with the full menu, and RackTrace remembers your choice for each. A device that is not linked to a documented device yet is monitored too; link it under Discovery to see its rack and cables in the panel and to use **What if this fails**. ### Notifications Under **Monitoring → Settings → Who gets a mail**, a notification policy mails its recipients when an alert opens and when it is resolved, for alerts of at least its minimum severity (warning and critical, critical only, or everything), optionally only for one site. Each recipient gets at most one open and one recovery mail per alert. A waiting time delays the open mail; if the alert is resolved within it, neither mail is sent. When a warning escalates to critical, a policy that only takes critical alerts gets the open mail at that moment. Without a policy nobody is mailed; the workspace then says **No notification policy**. **A silent scanner.** When a scanner that measured for a tenant goes silent (none of the tenant's checks on it — its device checks included — has a sample in its last three intervals, the rule that shows **Silent** next to the scanner at the top of the workspace), the policies of that tenant mail **Scanner silent** once; when it measures again, they mail **Scanner measuring again** once. This is not an incident: the network may be fine, RackTrace just cannot see it, and its devices are **unknown**. The monitoring worker looks every minute, so the mail follows within about a minute. Next to the scanner the workspace says whether it was e-mailed (counting only the mails the mail server accepted), that no policy mails it, or that maintenance holds it back. How a policy applies: - Every enabled policy that mails openings gets the silent mail, whatever its minimum severity: a silent scanner leaves it without any incident at all. A policy for one site only gets it when one of the scanner's checks of the tenant is at that site. - The back mail goes only to the recipients that had the silent mail, if their policy mails recoveries. - A waiting time delays the silent mail; if the scanner measures again within it, neither mail is sent. - A scanner that serves several tenants is mailed to each tenant about itself only. A scanner that never measured for the tenant is not mailed. - A controller (UniFi, Meraki, FortiGate, Auvik) whose sync is late gets no such mail: its devices become **unknown**. ### Maintenance A maintenance window covers the whole tenant, one site, one device or one scanner (**Monitoring → Settings → Maintenance**, which lists the active and planned windows; **Maintenance** in the device panel or on an alert; **Maintenance…** next to a scanner at the top of the workspace). While it lasts, failures are still measured and alerts recorded, but nobody is mailed. A window on a device covers its checks made by hand too. A window on a scanner only holds back the mails about that scanner falling silent and measuring again; alerts of its devices and checks still mail. A window on the tenant holds back both. When a window ends while the scanner is still silent, the silent mail is sent then. A window can be ended early. ### Thresholds When a value becomes an alert is set in the profile. The standard profile, every alert a warning: | Value | Alert | Resolved | |---|---|---| | Load of a watched port | above 90% for 10 minutes | below 80% for 5 minutes | | Errors of a watched port | above 10 a minute for 15 minutes | below 2 a minute for 10 minutes | | Discards of a watched port | above 100 a minute for 15 minutes | below 20 a minute for 10 minutes | | CPU | above 90% for 15 minutes | below 75% for 10 minutes | | Memory | above 95% for 30 minutes | below 90% for 10 minutes | | PoE budget | above 90% for 15 minutes | below 80% for 10 minutes | | Fans, power supplies | the device reports one failed | for 10 minutes no more | | Temperature | the device reports a sensor too warm (no fixed degrees: what is normal differs per sensor; a profile can add a number) | for 10 minutes no more | Discards have a higher threshold than errors: quality of service drops some packets on purpose, so only a port that keeps dropping is an alert, never one burst. **Monitoring → Settings → Thresholds** changes them for the whole organization (administrators), for the tenant or for a site; **Thresholds…** in the device panel for one device. Each field you leave empty inherits from the level above: device, then site, tenant, organization, the standard profile. **Reset** removes what a level sets. An alert needs the value above its threshold for the set minutes, so a short peak is none. Once it is open, a value between the **resolved below** value and the threshold keeps it open: a value around the threshold is one alert, not a flapping one. One open and one recovery mail per alert, as for every alert. A device that is down is one alert: its load, errors and health have none of their own meanwhile. ### Custom OIDs **Monitoring → Settings → Custom OIDs** reads a value the standard health does not cover — a UPS battery, a vendor counter — from every device of the tenant, from the switches, routers or access points, or from one device. Give a numeric OID under 1.3.6.1 and read it as one value (GET) or as a column of up to 64 rows (WALK, kept as the highest, lowest, sum or average); a counter becomes a rate per second. The scanner reads it with the device's health, so its value appears in the device panel within 5 minutes (there is no test button: the scanner only connects outward); give it a threshold to alert on it. Changing the OID, the way it is read or combined starts a counter again. Only numbers are kept: a text, an address or an OID is not a measurement, so no configuration or secret ends up in RackTrace. OIDs under 1.3.6.1.6 (SNMP's own management: users, access, engine) are refused. At most 20 per tenant and 10 per device. ### Credentials What the scanner logs in to a device with: **SNMPv1/v2c** (a community), **SNMPv3** (user, authentication and privacy), **SSH with a password** or **SSH with a key** (both optionally with an enable password). **Monitoring → Settings → Credentials** holds a standard for the whole tenant and one per site; a device's panel, under **Logging in**, shows what it would log in with and holds a **deviation** for that one device. - **The closest level wins, per protocol**: the device's deviation, then its site, then the tenant, then the credentials of the scan job that found it. An SSH deviation on a switch leaves the site's SNMP standard in force. A deviation replaces the standard; it is not added to it. - **A short list, in order**: at most 5 per level and protocol, tried first to last (↑ ↓ change the order). What works on a device is remembered: from then on only that one is used, until someone lets go of it, or until three measurements in a row find the device answering a ping but not SNMP with it — then the list is tried again. - **Only where the scanner itself looked**: credentials go only to an address one of the tenant's scan jobs found itself, inside that job's address ranges, as a network device. A device that only a controller, a push source, a JSON source or NetBird reports — also a switch with a public address — a check with a target of its own, and a host the sweep found get none. The device panel says why. - **SSH standards only on network equipment** (switches, routers, firewalls, gateways, access points): fewer failed logins at the customer. A deviation for one device is used on that device whatever it is. - **One exception for SSH**: a host the sweep of a scan job found, at an address inside the job's ranges, whose MAC address another source of the **same tenant** reports as network equipment (a UniFi switch without SNMP) may get the SSH credentials of its level — never SNMP ones. The same MAC address in another tenant gives nothing. - **SSH keys**: paste one (OpenSSH, PEM or PKCS#8; ed25519, ECDSA P-256/P-384 or RSA of at least 2048 bits) or let RackTrace make an ed25519 key and put its public key on the devices. A PEM or PKCS#8 key may be protected with a passphrase: RackTrace uses it once to read the key and never keeps it. An OpenSSH key with a passphrase is refused; convert it first: `ssh-keygen -p -m PKCS8 -f ` keeps the passphrase. Keys are recommended: an SSH password goes to the device as it is. - **Nobody sees a value again**, administrators neither: the screens say only that it is set. Leave a field empty to keep it; type a new one to replace it. Values are stored encrypted, each bound to its organization and tenant, and never appear in exports, mail, the history or what the scanner sends back — RackTrace masks every value a scanner was given (also one changed or deleted in the last 24 hours, of a scan job too) as `••••` in everything the scanner sends back before it is stored — details, the names, descriptions and aliases of interfaces, the vendor and sensor names, test results — a value of 1 to 3 characters only where it stands on its own, not inside another word, so ordinary text stays readable. Use longer values. - **SSH keys with a passphrase**: RackTrace opens at most 1,000,000 PBKDF2 rounds (or scrypt with N × r × p up to 262,144); a key stretched further is refused before it is opened. - **Who**: an administrator, or a user with the right **Credentials** on the tenant (given through a group — an editor does not get it by role) sets, changes, orders and deletes them. Anyone with the right Monitoring sees which there are and tests them. An API token reads and tests them, never sets them. Every change is in the history, without the value. - **Unreadable after a copy**: a value copied into another organization (a restore or a copy of the data) does not open there. The credential says so; delete it and enter it again. - **Scan jobs**: the SNMP credentials of a scan job stay the lowest level. The key button of an SNMP job under **Integrations → Scanner** makes them the standard of the job's site. #### Delivered sealed for the scanner's own key The agent (version 1.7.0 and newer) makes a key pair of its own at its first start (`agent-key.pem` next to `agent.json`) and names the public key whenever it contacts RackTrace. RackTrace pins the first key a scanner presents, and from then on seals **every** credential it sends that scanner for that key — those set here and those of its scan jobs (an SNMP community, a FortiGate token) — bound to that scanner, so a proxy that opens HTTPS reads none of them. The agent keeps them in memory only and cleans what it sends back of them too. The other way is not sealed: [configuration backups](https://docs.racktrace.io/network/monitoring#config-backup) go to RackTrace over HTTPS, and a proxy that opens TLS can read them. - **Compare the fingerprint**: **Integrations → Scanner** shows the fingerprint of the pinned key; the agent shows the same on its own page (port 8095) and in its log. Compare them and tick **I compared the fingerprint** (in the history): the key is pinned at first contact, and only the comparison shows that it is the agent's own. - **Scanner key changed**: another key afterwards — the agent installed anew, or someone with the scanner's token — or no key at all (an older agent, whatever version it states) **pauses** the scanner: no scan jobs, no SNMP measurements and no credentials at all, also not those of its scan jobs. Its checks over SNMP are shown as unknown with the reason *scanner key changed, waiting for acceptance* — not as down. Its tenants get the [security alert](https://docs.racktrace.io/network/network-plan) *Scanner key changed*. An administrator accepts exactly the fingerprint shown under **Integrations → Scanner** (in the history); then it measures again. Accepting *no key* forgets the pinned key: the next key the agent presents is pinned again as at its first contact, and the fingerprint is to be compared again. Did nobody reinstall it? Make a new token for the scanner instead. - **An agent without a key of its own** (older than 1.7.0) gets only the credentials of its scan jobs, as before. The screens say **Update the agent**, and a device whose credentials are set here is shown as unknown with that reason, not as down. - **Test** (next to each credential, and per credential in a device's panel): the scanner tries that one credential on one device of its own level — a site standard on a device of that site, a tenant standard on a device of the tenant, a deviation on its own device — at its next contact, within a minute. The test runs in the background: close the window or go on working, also on another page or after a reload; the outcome comes as a message and stays with the credential and the device as its last test. When the scanner does not answer within three minutes, the message says so. Outcomes: *SNMPv3 ok: sw-core-01, …*, *wrong authentication password*, *unknown user name*, or *no answer on UDP 161*. What works becomes the device's binding at once. Each failed test is a failed login at the customer, so: one test per 2 minutes of a credential on a device, at most 10 per hour per person or API token and 30 per hour per tenant. Every test, also a refused one, is in the history. An SSH test (scanner 1.8.0 and newer) says what the host key is, the prompt, what the device was recognised as and whether enable worked — *SSH key ok: host key ssh-ed25519 SHA256:…, prompt sw-core-01#, recognised as Cisco IOS / IOS-XE, enable: yes* — or why not: *password refused*, *TCP 22 refused*, *Host key not confirmed yet — not logged in*, *the host key changed*, *only older algorithms*. A password test on a device whose host key nobody confirmed only reads the host key: the password does not go. #### SSH in the scanner From agent **1.8.0** the scanner logs in to the network devices it found over SSH, with fixed read-only commands per vendor, and reads what SNMP gives poorly or not at all: version, model and serial, the inventory, the interfaces with their VLANs (access, trunk, native, tagged), LLDP and CDP neighbours and the MAC table. That goes into discovery with the next scan of the job that found the device, where SNMP gave nothing: the ports, the map and the clients per port. A scanner older than 1.8.0 gets no SSH credentials at all; the screens say *SSH works from scanner 1.8.0 on*. - **Vendors**: Cisco IOS / IOS-XE, Aruba AOS-S (ProCurve) and AOS-CX, FortiGate and MikroTik RouterOS. The vendor is recognised from what RackTrace knows of the device, the SSH banner and one version command per candidate; what is not recognised gets no command at all (*SSH ok, vendor unknown*). - **Only reading, only these commands**: Cisco `terminal length 0`, `show version`, `show inventory`, `show interfaces status`, `show interfaces trunk`, `show vlan brief`, `show lldp neighbors detail`, `show cdp neighbors detail`, `show mac address-table`; AOS-S `no page`, `show system`, `show interfaces brief`, `show vlans`, `show lldp info remote-device`, `show mac-address`; AOS-CX `no page`, `show version`, `show system`, `show interface brief`, `show vlan`, `show lldp neighbor-info`, `show mac-address-table`; FortiGate `get system status`, `get system interface physical`; MikroTik (as `+ct`) `/system resource print`, `/system routerboard print`, `/system identity print`, and `print terse` of `/interface`, `/ip neighbor`, `/interface bridge vlan` and `/interface bridge host`. They are in the agent itself: RackTrace cannot send another one. A command the device refuses (*% Invalid input*, *Permission denied*) is shown as *too few rights*, never as an empty table. - **A read-only account**: Cisco IOS needs privilege 15 (or a `parser view`) for some show commands — give the account an enable password if it logs in at a lower level (like the SSH password, it goes only to a confirmed host key); AOS-CX the role `auditors`; FortiGate an administrator profile with read access only; MikroTik the group `read`. - **When**: every 4 hours per device (set 1 to 24 hours under **Monitoring → Settings → Credentials**), at once with **Fetch now** in the device panel, and right after a Cisco reports over SNMP that its configuration changed. Each login is in the logs of the device. Without a credential that worked on a device, its list is tried at most once an hour; one that is refused three rounds in a row is let go of. - **Limits per session**: 60 seconds and 4 MB of output; one session per device and at most 8 at a time per scanner. - **Algorithms**: only current ones (curve25519, ECDH, group14-sha256; ed25519, ECDSA, RSA with SHA-2; AES-GCM and AES-CTR). An old device that offers nothing else needs **Allow older algorithms** on its credential; the test says so. - **The client**: `ssh2` 1.17.0 (MIT), bundled in the one agent file and signed with it. Its optional native parts are left out; it uses its JavaScript implementations. ##### Host keys The scanner checks a device's SSH host key before it logs in: before a password or a signature goes. RackTrace keeps per device the key it met and how far it is trusted — the device panel, under **SSH**, shows it: - **Seen**: met, but trusted for nothing (a key login that failed, or a password that waits). - **Pinned**: at the first contact with an **SSH key** the scanner may log in (a key only signs this one session) and the host key is pinned. A pinned key counts for keys only, never for a password. - **Confirmed**: by someone with the right Credentials, after comparing it with the device itself (the device panel shows how: `show ip ssh`, `show crypto key mypubkey`, `show ssh host-key`, or `ssh-keyscan
| ssh-keygen -lf -` from a computer in that network). Only then may an **SSH password** or an **enable password** go — never at a first contact, never to a key that is only pinned; with a key that is not confirmed the scanner reads with the rights the account has (*enable: no*). A confirmation counts at the address it was given for: the same key met at another address (cloned virtual machines and devices with a default host key share keys) is pinned again until it is confirmed there. You can also fill in the fingerprint beforehand. - **Host key changed**: another key than the trusted one, whatever its trust, stops the scanner before it logs in, and the tenant gets the [security alert](https://docs.racktrace.io/network/network-plan) *SSH host key changed*. Nothing goes to that device until someone with the right Credentials accepts the new key — in the device panel or at the alert — which makes it confirmed. A replaced switch? Compare first. Not a change you know of? Do not accept it. - **The list per site** (**Monitoring → Settings → Credentials**, **SSH host keys** under the site) confirms many at once: one row per device, address and fingerprint, with whether the device is linked to a documented device, since when the scanner sees it, and category and MAC as the host itself reports them. New and undocumented rows are not ticked beforehand. - **Always the pair you were shown**: a confirmation or acceptance sends the device, address and fingerprint you saw. If the key changed in between — also at the very same moment — nothing is confirmed: *The host key changed since you saw it — look at it again*. A host that appeared after you opened the list is never confirmed with it. Every confirmation, acceptance and refusal is in the history, one line per pair. An API token confirms or accepts nothing. - **What is left**: someone who confirms a fingerprint without comparing it gives that host the SSH password and the enable password. With a key at the first contact a fake device gets no secret, but can send false data until someone notices. #### Configuration backup From agent **1.9.0** the scanner also backs up the configuration of every device it may log in to over SSH, in the same session as its SSH round: the **running configuration** and, where the device has one, the **startup configuration**. RackTrace keeps a new version only when something changed, and shows what changed between any two versions. It never writes anything back to a device: to restore, download a version and put it back by hand. - **What is read**, with the fixed read-only commands: Cisco IOS / IOS-XE `show running-config` and `show startup-config`; Aruba AOS-CX `show running-config` and `show startup-config`; Aruba AOS-S `show running-config` and `show config`; FortiGate `show` (what differs from the defaults); MikroTik `/export terse` (RouterOS 7 leaves secrets out itself). - **Only from a confirmed host key**: a configuration is backed up only from a device whose [host key](https://docs.racktrace.io/network/monitoring#ssh-host-keys) someone with the right Credentials confirmed at that address — also with an SSH key, and for every vendor. A host key that is only pinned would let something that pretends to be the switch put a false configuration in the history. Until it is confirmed the backup says *Host key not confirmed*, the scanner reads no configuration and no version is made. - **Rights**: Cisco and AOS-S show their configuration only in privileged mode — privilege 15, or an enable password (which also goes only to a confirmed host key). Without it the backup ends with *No rights to read the configuration*, and nothing is read. - **When**: once a day per device (set 1 to 24 hours, or daily, in **Monitoring → Settings → Configuration backups**), at once with **Fetch now** under **SSH** in the device panel, and right after a Cisco reports over SNMP that its configuration changed. A failed backup is tried again with the next SSH round. - **Only a change is a version**: lines that change at every read are left out before comparing — the size and time in the header, *Last configuration change*, *ntp clock-period*, the time of a RouterOS export. A read without a change only updates *last checked*. - **The difference**: tick two versions under **Configuration** in the device panel (also running against startup), or **Changes** next to a version: line by line, with the section each change falls in (*interface GigabitEthernet1/0/5*, *vlan 30*, *config system interface › edit port1*). - **Secrets are masked** everywhere RackTrace shows a configuration — the screen, the difference, notices, their e-mail, the change log of discovery and the timeline of an incident: lines with a password, secret, key, community, pre-shared key and the like show `••••`, and so does every value of a credential RackTrace gave the scanner — also one changed in the last 24 hours — wherever it stands. A secret that changed shows as a changed line, without its value. This is done when the version comes in, so a value deleted later stays masked. - **The download** holds the configuration as the device gave it, secrets included. Only someone with the right **Credentials** may download (in the history); an API token never. - **Kept**: every version a year, and always the last 20 of a device, however old. A device no longer monitored keeps them until it has been retired for 90 days (it is retired after 30 days away). Older versions are deleted for good. Versions are stored compressed and encrypted, bound to the device; they are not in the exports, not in the MCP tools and not in a snapshot of the organization. So a restore of one organization (from its nightly backup or a snapshot) does not bring back the configuration history; only a backup of the whole database holds it. - **Notices** (with the e-mail of the notification policies; only the device, the lines added and removed and the sections — never a line or a value of the configuration): *Configuration changed*; *Running configuration not saved* (Cisco and Aruba: running differs from startup for more than 24 hours, so a restart would undo it); *Configuration backup failed* (three times in a row). Each can be switched off per tenant under **Notice settings** in **All tenants**, as the notices of discovery. **Monitoring → Settings → Configuration backups** lists the last backup of every device per site; old (more than twice the interval), failed or never made stands out. - **Limits**: at most 2 MB per configuration, each read apart from the 4 MB a session may read otherwise; a larger one is a failed backup with the outcome *larger than 2 MB*. - **A version that does not open** (copied in from elsewhere, or encrypted with a key RackTrace no longer has): the next one is a new baseline, and says so — *previous version unreadable — new baseline*, in the notice *Configuration changed* and in the change log. - **On the way**: configuration backups go to RackTrace over HTTPS, as read; a proxy that opens TLS can read them. (Credentials go the other way sealed for the scanner's own key, see [above](https://docs.racktrace.io/network/monitoring#scanner-key); a configuration is not sealed that way yet.) ### Other checks Checks of a website, a certificate, a DNS name or a TCP service — what a network device does not report itself — are made through the API (`POST /api/tenants/{id}/monitoring/checks`) and measured by a scanner: - **ICMP**: one ping; records reply time and packet loss. - **TCP**: opens a configured `host:port`. - **HTTP/HTTPS**: checks the response status and, optionally, required text. Responses are read up to 64 KiB and redirects are not followed. - **DNS**: resolves a host name and records lookup time. - **TLS**: reads certificate expiry from `host:port`; the default warning starts below 14 days. - **SNMP device** and **SNMP port**: uptime, and one port's state and counters. A check made for a documented or discovered device is part of that device: it is listed under **Checks** in the device panel, a failure counts on the device in the list and on the map, its alert is an alert of that device, and maintenance of the device covers it. Such a check opens an incident after three failed observations and resolves it after two good ones. Rules can turn a numeric metric into **degraded** (warning) or **down** (critical). A device page shows its measurements. The checks of device monitoring itself cannot be changed or deleted by hand: they follow discovery and the profile. A check can also depend on a parent check of the same tenant (`depends_on_check_id` in the API). While the parent is down or degraded, a failure of the child opens no incident of its own (one failure, one alert); it opens one at its next failure once the parent is back. Only a parent that measures counts: a parent without a sample in its last three intervals, or one that was never measured, is unknown, not down, and the child alerts as if it had no parent. A check made by hand without a parent hangs on the device check of its device, and only when that device is down: a device that is degraded leaves the check its own alert. The **incident page** — the link in every mail, and **Open** on an alert — is the incident as a workplace: what is wrong, where, since when, how sure, and what it affects, on one screen. Anyone with access to the tenant can read it; acting on it (acknowledge, **Measure now**, **Maintenance**) needs the monitoring permission. A link from a mail opens in the tenant the incident belongs to; without access to that tenant you see no data. - **Now** — at the top, the status of the check now and how fresh it is (measured 2 min ago by which scanner, or **unknown** with no measurement since …), and how many items of evidence are missing or stale, or that none are. If another source of the device reports it otherwise (UniFi has it online while the scanner cannot reach it), that is said here too: the status follows the measurement. - **Evidence timeline** — from two hours before the incident opened to its recovery (or now). Every item names its source and time: the measurements as runs of one status, with the stretches where the scanner sent nothing as silences; the incident opening, escalating, being handed over from one measurement to another, being acknowledged and recovering (or being closed, with why), and its mails; the scanner's errors and last contact; the last discovery of the device's scope and what it saw of the device and its port; open security alerts of the tenant; and changes to the documentation of the device, its ports and cables, the check and the incident. Each source has a limit, so a long or flapping incident stays fast: what a limit leaves out is counted. - **Where** — the device and its location, the port with its cable trace, the VLANs as documented and as discovery last saw them, and the IP addresses. - **Sources** — when the scanner last measured and whether it is silent, and when each discovery scope last synced and saw the device, including the other sources that see it. - **Impact** — the checks that depend on this one, with their state, and **What if this fails**: the simulation with a new scenario in which the device (or, for a port with a documented cable, the link) fails. - **Missing or stale evidence** — named at the top: a check not linked to a device, a port without a documented one, no cable, a device no discovery knows, a silent scanner, a check never measured. - **Actions** — what was measured on request, and the maintenance that covers the check now. **Measure now** asks the scanner to measure the incident's check at once, through the same route as its regular measurements; for a port, load or health incident of a device it asks the SNMP read of that device, which measures them all. The scanner fetches its checks every minute: the new measurement appears on the page as soon as it arrives, and the page waits for it up to 3 minutes. If the scanner has not fetched the request by then, the page says so, with its last contact: it may be silent, and no new measurement is no evidence that all is well. A check is measured on request at most once every 2 minutes — whoever asks, from the incident or with Run on the check; a second request is refused with the time to wait. Only what is monitored already can be measured: a device or site a controller reports has no **Measure now** (RackTrace reads it at the controller's next status poll). **Maintenance** pauses the mails of the incident's device (all its checks) or of only its check, for 1, 4, 8 or 24 hours, with a reason. It is the same maintenance as under **Monitoring → Settings → Maintenance**, and can be ended there. Every request to measure and every maintenance started from an incident is in the audit log and on the incident's evidence timeline, with who did it. **Report** opens the incident as a report to hand over to a colleague or a customer: the incident, the status now with its age, missing or stale evidence, where it is (with the trace), its impact, the timeline with the source of every item, the sources and what was done from the incident. **Print** makes a PDF (choose *Save as PDF*); **Copy as Markdown** puts the same report on the clipboard for a ticket or a mail. Times in the report are in UTC. The report is not shared as a link: send the PDF or the text. An open alert of a check that no longer measures says so on its row in the workspace: **Unknown · no measurement since …**. ### Ports, counters and gaps The first sample of a port establishes a counter baseline, so it has no traffic rate. RackTrace also leaves rates empty after a reboot, a counter-width change, a gap over one hour, an impossible value, or a discontinuity it cannot safely interpret. These empty points prevent a false traffic spike. Two more cases: a device whose counters of one interface were reset without a restart ("clear counters", seen from `ifCounterDiscontinuityTime`, agent 1.5.0), and a device with only 32-bit counters on a link faster than about 570 Mbit/s, where a counter can wrap more than once a minute — its load is **unknown**, never shown too low. ### Availability, history and capacity Availability is `100 × (up + degraded) / (up + degraded + down)`; **unknown** samples and missing intervals are left out. Raw observations are kept for 30 days by default, hourly roll-ups for 13 months, resolved incidents for 24 months. A device measured by the scanner gives 1,440 samples a day; a watched port that stays up is stored once every 5 minutes (at most 288 a day), and every minute while it is down. A load, error or health alert that stays below its threshold is stored once every 15 minutes (96 a day), and every measurement while it is above. A device reported by a controller gives one sample per sync and status poll. The charts come from one row per device per 5 minutes, all its interfaces and its health together (288 a day), kept 8 days; and one row per hour, kept 90 days. The monitoring load report of the management portal counts these rows per day. ### Targets and limits A check measures the customer's own network: private addresses (10/8, 172.16/12, 192.168/16, IPv6 ULA), public addresses, and services on the scanner itself (loopback) are all allowed. Never allowed, with no exceptions: - **Link-local addresses**: 169.254.0.0/16 and fe80::/10, also when written inside IPv6 (`::ffff:169.254.169.254`). Cloud metadata services live there; give a device that only has such an address a routable one first. - **Cloud metadata services** by name or address: `metadata.google.internal`, `metadata.goog`, `metadata`, `instance-data`, `fd00:ec2::254` (AWS) and `100.100.100.200` (Alibaba Cloud). RackTrace checks the target when the check is created. The agent (1.3.2 or newer) checks it again after DNS, because a host name can point anywhere: when any address of the name is refused, the check is **unknown** with the reason and no connection is made. Otherwise the agent connects only to the addresses it checked. | Kind | Target | Settings (`config`) | |---|---|---| | ICMP, DNS | host name or IP address | none | | TCP | `host:port`, IPv6 as `[address]:port` | none | | TLS | `host:port` | `warn_days` (0–365) | | HTTP | `http://` or `https://` URL | `expect_status` (100–599), `body_match` (1–256 characters), `verify_tls` (true/false) | | SNMP device | host name or IP address | `port` | | SNMP port | host name or IP address | `if_index` (required), `port` | A target never holds a user name or password. Limits for the checks made through the API: the timeout is at most the interval; a scanner has at most 1,000 checks and a tenant at most 2,000 (the checks of device monitoring do not count). A scanner may push at most 60 monitoring batches a minute (per address 120). ### Troubleshooting - **A device is not in the workspace**: is it a switch, router, firewall, gateway or access point, linked to this tenant through its scope, and not ignored under Discovery? A device found by the scanner needs an IP address. - **Unknown, "agent older than 1.4.0"**: update the scanner's agent; it updates itself when signed updates are on. - **Silent source**: check the agent's console and log, outbound HTTPS, the scanner token, its clock and its route to the devices; for a controller, its last sync under Integrations. - **Up, "answers a ping, not SNMP"**: check UDP 161 from the agent, the SNMP version and credentials of the tenant's SNMP scan. - **No mail**: is there a notification policy for the severity, and no maintenance window? Is the alert behind a device that is down (then that device has the alert)? Acknowledging an alert does not resolve it. For a silent scanner, the workspace says next to it whether it was e-mailed, that no policy mails it, or that maintenance holds it back. - **Traffic rate is empty**: wait for a second valid sample; then check for a restart, a long gap or a counter reset. - **Health "agent 1.5.0 or newer"**: the scanner's agent measures interfaces but not health; update it. - **A health value "not reported by this device"**: the device has no MIB for it (or it is switched off). Check under Custom OIDs whether a vendor OID gives it. - **Load unknown, "32-bit counters"**: the device offers only 32-bit counters on a fast link; enable SNMPv2c or v3 (64-bit counters) on it. ### Upgrade and rollback Device monitoring starts on its own after the upgrade: every tenant with a discovery source is monitored from its next sync, and a tenant with a notification policy gets mails about its network devices. Checks made earlier with "Enable proposed monitoring" keep working; **Monitoring → Settings** offers to switch them off, since device monitoring measures the same devices. Health and custom OIDs need agent 1.5.0; load, errors, discards and their charts already work with 1.4.0; since when an interface changed and its duplex need 1.7.2. Signed agent updates are downloaded automatically where enabled. For a rollback, deploy the previous application image and leave the monitoring tables in place: history and open incidents must remain when the new image returns. --- ## All tenants > One screen for the whole MSP — every tenant's monitoring, the ones that need attention first — and notices of a new network device or a changed IP address. URL: https://docs.racktrace.io/network/all-tenants **All tenants** shows the monitoring of every tenant you have access to on one screen, the ones that need attention first. Below it are the open **notices**: a network device a tenant did not have before, or a device with another IP address. Open it from the side menu; it is there when you have access to more than one tenant. ### What it shows One row per tenant; open a tenant to see its sites. Per row: - **Devices** — the monitored devices that are up, down (or warning) and unknown, and how many are in maintenance. The same counts as the tenant's [workspace](https://docs.racktrace.io/network/monitoring#workspace): a device without a recent measurement is unknown, never its last status. - **Alerts** — open incidents by severity (acknowledged ones apart), the open [security alerts](https://docs.racktrace.io/network/network-plan) of the tenant's network. - **Sources** — a scanner that went silent for the tenant, and a discovery source whose last sync failed. - **Notices** — open notices of a new device or a changed IP address. - **Measured** — the newest measurement, and a maintenance window on the whole tenant or site. The order is what needs attention first: a critical incident, then a silent scanner, a device down, a warning, a notice, unknown devices, and then the tenants where all is well. A tenant with monitoring switched off comes last. **Needs attention only** hides the rest; the search finds a tenant or a site. **Open** goes to the workspace of that tenant. The screen updates every minute. Only the tenants you have access to are on it — by your own access or through a group — and every count is about those tenants only. There is no total for the whole organization. ### Notices A notice is made when discovery sees: - **a new network device** — a switch, router, firewall, gateway or access point the tenant did not have before. A device that another source of the tenant already reported (the same MAC address), or that is monitored already, is not new. All new devices of one report are one notice: ten new access points in one scan are one notice, and one mail per recipient. - **an IP address changed** — of a network device, or of a client that is linked to a RackTrace device. While the notice of a device is open, another change of its address updates that notice (its newest address and how often it changed) instead of making a new one. A notice is not an incident: nothing is down, and there is no recovery. It stays open until someone with the monitoring right clicks **Seen**; the history keeps who did. **Change log** opens the tenant's [change log](https://docs.racktrace.io/integrations/discovery#changes) under Discovery. No notice is made: - at the first report of a new source or site — that report is the starting point to compare with; - while a maintenance window covers the tenant or the site (or, for an IP change, the monitored device). A window on a scanner does not count: it only holds back the mails about that scanner; - when monitoring, or that kind of notice, is switched off for the tenant. Laptops, phones and other devices that are not linked to RackTrace devices never give a notice: they come and go all day. ### Mail and settings A notice is mailed to the tenant's [notification policies](https://docs.racktrace.io/network/monitoring#notifications) that mail openings, whatever their minimum severity; a policy for one site only for notices at that site. Each recipient gets one mail per notice, about that one tenant. A waiting time of the policy delays it; a notice marked as **Seen** before then is not mailed. **Notice settings** lists every tenant whose monitoring you may change, with **New device** and **IP address changed**. Both are on for every tenant; **All on** and **All off** set them for all tenants at once. --- ## Routing, WAN, VPN, WiFi and firewall > Document static routes, WAN connections, VPNs, WiFi networks, firewall zones and rules, port forwards and DHCP reservations. URL: https://docs.racktrace.io/network/routing-and-firewall Next to VLANs, the network plan documents how the network reaches the outside world and who may talk to whom. ### Adding and editing objects These tabs all work the same way. Each card has a **New …** button (**New static route**, **New WAN connection**, **New VPN**, **New WiFi network**, **New firewall zone**, **New firewall rule**, **New port forward**, **New reservation**), an edit and a delete icon per row, and **CSV** to export the card. - **Static routes**: name, destination, type, next hop, interface, distance, enabled. - **WAN connections**: name, port, type, provider, IP, gateway, VLAN, download and upload speed (the simulation uses these), role (primary, failover …), DNS and gateway device. - **VPNs**: name, kind (site-to-site, remote access, client), protocol, subnet, remote subnets, peer, enabled. - **WiFi networks**: SSID, network, VLAN, security, bands, guest, hidden, enabled. - **Firewall zones** and **Firewall rules** (name, zones, action, source, destination, protocol, ports, order, enabled). The [simulation](https://docs.racktrace.io/network/simulation#sim-firewall) checks traffic against these rules. - **Port forwards**: name, WAN, external port, protocol, to IP and port, allowed from. - **DHCP reservations**: MAC address, IP address, name, network. With more than one site there is also a **Location**. Objects read from UniFi carry a **UniFi** badge; your edits are kept until you take over a change for that object in the [UniFi review](https://docs.racktrace.io/network/unifi-review#from-unifi). --- ## Configuration from UniFi > Compare the network plan with what UniFi reports, take over changes, and check security alerts. URL: https://docs.racktrace.io/network/unifi-review With a UniFi site linked, RackTrace reads the configuration of the console, shows what differs from the network plan, and warns about changes that can open up the network. ### Reviewing what UniFi reports With a UniFi site linked, a banner at the top says how many differences UniFi reports. Click **Review**, or open the **From UniFi** tab. ![The From UniFi review](https://docs.racktrace.io/assets/screens/unifi-review.webp "The From UniFi review: what UniFi reports compared with the network plan.") 1. Go through the sections: VLANs, port profiles, switch ports, routes, WAN, VPNs, WiFi, firewall, port forwards, DHCP reservations and IP assignments. 2. Each item is **new**, **change** (with every field from → to) or **remove**. Tick what to take over; **All** and **None** work per section. Removals are never ticked by default. 3. When two sites in one network report the same VLAN with different settings, choose under **Take it from:** which site the plan documents. 4. Click **Apply** in the bar at the bottom. Every difference is also a [deviation with a status](https://docs.racktrace.io/integrations/discovery#deviations): the chip next to an item says whether it is open, accepted or ignored, and the line above the sections counts them. What you apply is resolved straight away. With **Keep the documentation in sync** on (it is off until you switch it on), the VLANs of the switch ports of linked devices are taken over by themselves, together with the VLANs and port profiles they need; the review then has no switch ports left for those devices (see [The documentation follows the network](https://docs.racktrace.io/integrations/discovery#docs-sync)). Nothing is ever written to UniFi. New VLANs get the site's gateway as gateway device, so the route check works straight away. A switch port whose VLANs match no profile gets a new profile, such as *UniFi 20+30*. Passphrases, keys and passwords are never read into RackTrace. ### Security alerts After every sync, RackTrace compares the UniFi configuration with the previous one. Changes that can open up the network become an alert. A red number at **Network plan** in the menu and a banner on the dashboard show how many are open. | Severity | What raises it | |---|---| | High | A new, changed or switched-on port forward. A blocking firewall rule removed, switched off or now allowing. An open WiFi network that isn't a guest network, or a WiFi network moved to another network. Isolation switched off, a network that is no longer a guest network or moved to another firewall zone. A new VPN. | | Medium | A new allow rule, or a blocking rule that changed. An open guest WiFi. Internet access allowed for a network. A VPN switched on, or with other remote subnets or peer. Switch ports in another VLAN. | #### Checking the alerts 1. Open the **Security alerts** tab. Filter on **Open**, **Seen** or **All**. 2. Check each alert. **Compare with the plan** opens the matching part of the review. 3. Click **Mark as seen** (or tick several and **Mark … as seen**, or **Mark all as seen**). Add a **Note**, such as why the change is fine. Who marked it, when, and the note are kept with the alert and in the history. The first sync is the baseline and gives no alerts. The checks of a [watched simulation scenario](https://docs.racktrace.io/network/simulation#sim-watch) that fail are alerts too, with **Simulation** as their source and **Open the scenario** to go back to it. --- ## Network simulation > Test a change to the network before you make it — every layer from cable to firewall, port configuration, failures and traffic. URL: https://docs.racktrace.io/network/simulation “What happens if …”: a port gets other VLANs, a switch fails, a firewall rule is added, or forty cameras start streaming. The simulation answers from what is documented: the cabling and port speeds, VLANs and port profiles, the network plan (gateways, routes, firewall rules, port forwards), plus the current load from UniFi when it is available. A scenario is a sandbox. Nothing you change in it goes to the documentation or to the network. The results are decision support for planning, not a packet-level simulation: every run says on what it rests (see [What a result rests on](https://docs.racktrace.io/network/simulation#sim-run)). ![The simulation workspace with a scenario, the network map and the results](https://docs.racktrace.io/assets/screens/simulation.webp "Simulate from a workstation's port: a check to the internet and 1 Gbit/s of traffic, its load and way on the map.") ### The workspace Open **Network → Simulation**. Everything is on one screen: - **Top bar**: the scenario (unsaved, or one you saved), **Save**, **New**, whether the results are **Up to date**, **Run**, and the settings (the key icon). - **Left**: the scenario, in three parts: **Changes**, **Checks** and **Traffic**. **Options** sits underneath. - **Middle**: the network map, with a layer to show (see [The map](https://docs.racktrace.io/network/simulation#sim-map)). - **Right**: the inspector. It shows what you clicked: a check, a device, a link, a change or traffic. With nothing selected it lists what needs attention. - **Bottom**: the results, in tabs. The arrow at the right of the tabs gives them more room. Each change runs the scenario again by itself. **Run** runs it once more, for example after a colleague changed the documentation. The scenario stays while the browser tab is open; save it to keep it. ### Changes Click **Add** under **Changes** and choose what changes: | Change | What it does | |---|---| | **Port configuration** | Gives a port another port profile or its own VLANs (untagged and tagged, or **All others tagged**), or switches the port off or on. | | **New cable** | Patches or lays a cable between two free ports, for example a backup uplink. It becomes part of the network: spanning tree, paths and VLANs take it into account. Choose the **Cable type** and the **Length (m)**. | | **Device fails** | A switch, gateway or other device goes down. | | **Link fails** | A cable, or a LAG between two network devices, breaks. | | **Internet connection fails** | A WAN connection of a gateway goes down. The next connection documented in the [network plan](https://docs.racktrace.io/network/routing-and-firewall) takes over with its own speed, such as a 4G backup. When none is left, there is no internet. | | **VLAN gateway** | Routes a VLAN on another device, for example a layer-3 switch. | | **Static route** | Adds a route, or switches a documented route off. | | **Firewall rule** | Adds a rule, first or last, or switches a documented rule off. | | **Broadcast storm** | A faulty device on a port floods its VLAN. Set the **Rate** and the **Storm control** percentage (0 = off). | | **Loop cable** | Someone patches a cable between two ports, with **Spanning tree** on (RSTP, the UniFi default) or off. | | **Powered devices** | More cameras, access points or phones on a switch: **How many** and the **Watts each**. The [PoE tab](https://docs.racktrace.io/network/simulation#sim-poe) shows whether its budget holds. | | **QoS** | Switches *calls and video first* on or off for this scenario, whatever the [settings](https://docs.racktrace.io/network/simulation#sim-settings) say. | | **Traffic grows** | The [existing traffic](https://docs.racktrace.io/network/simulation#sim-existing) grows (or shrinks) by a percentage, for example +50% for a year of growth. | You can also start from the map: click a device or a link and use **Let it fail**, or **Change…** next to one of the link's ports. On a gateway, **Its internet fails** takes away all of its internet connections. The switch on a change takes it out of the run without removing it, so you can compare with and without it. The ✕ removes it. ### Checks: what must work, and what must not A check follows one packet through every layer and says where it stops. 1. Click **Add** under **Checks**. 2. Choose **From**: a **Device**, a **Port**, an **IP address**, a **VLAN** or a **WiFi network**. 3. Choose **To**: the **Internet**, a **Device**, a **Port**, an **IP address**, a **VLAN** or **Its gateway**. 4. Choose the **Protocol**: one from the list (HTTPS, DNS, SMB, RDP, VoIP and more, plus [your own](https://docs.racktrace.io/network/simulation#sim-settings)), or **Other…** with a protocol and a port. 5. Set the **Expectation**: **Must get through**, **Must not get through**, or **Only show the way**. Then click **Add check**. Each check is traced without and with the changes: - **L1, cable**: the path through patch panels and outlets, and the speed. A link that UniFi reports slower than both ends can do (100 Mbit/s on a gigabit link) is a warning: a bad cable or port, or a fixed speed. Parallel cables between two switches count as one LAG when their ports are in one; when the port configuration is documented and they are not, spanning tree blocks all but one. - **L2, VLAN**: on both ends of each link, whether the VLAN is carried, untagged or tagged, and whether both ends agree. - **L3, routing**: the IP address and the gateway of the VLAN, static routes (the most specific wins), blackhole routes, site-to-site VPN, and the WAN with NAT. - **L4, firewall**: the rules of the gateway, read per platform (see [Firewall](https://docs.racktrace.io/network/simulation#sim-firewall)), and port forwards for traffic that comes in from the internet. A check **gets through**, is **blocked**, or **probably** gets through: something on the way is not documented. RackTrace never takes something that isn't documented as allowed. In the list a check shows **passes**, **fails**, or **breaks** (it passed without the changes). Click a check to see each step in the inspector and its way on the map, with **STOPS HERE** where it stops. A step that stops at a port offers **Change this port in the scenario…**. A step at a firewall rule offers **Switch this rule off in the scenario**. ### Traffic Traffic puts load on the links. 1. Click **Add** under **Traffic**. 2. Choose **From**, a port or a device, and **To**: the internet, its gateway, a device or a port. 3. Choose the **Protocol**. It sets how the traffic behaves and its usual rate: a backup takes what it can get, a call or a camera is constant. 4. Set the **Rate (Mbit/s per session)** (or click **100M**, **1G**, **10G**), the number of **Sessions** and the **Direction**. Traffic is traced first, and traffic that doesn't get through carries nothing. The rest shares the links: what each flow gets, the bottleneck, the extra latency and the loss. When the protocol has needs (a call, video), the list also shows its quality, **good**, **at risk** or **poor**, an estimate of latency, jitter and loss against what the protocol needs. Click the traffic to see the figures per direction, and its way on the map. A few things count as links of their own: - **An access point**: traffic from or to an access point is its WiFi clients together. They share its radio, both directions at once (**WiFi per access point** in the settings). - **Site-to-site VPN**: traffic to another site that goes through a tunnel uses the upload of one WAN and the download of the other, and at most the **Site-to-site VPN** speed when it is set. - **QoS**: with *calls and video first* on, a call does not wait behind a full link: its latency and jitter stay low, while a backup gets what is left. ### Existing traffic The traffic you add comes on top of the traffic that is already there. Choose it under **Existing traffic** at the top of **Traffic**: - **Now — as UniFi reports it**: the load on every port at the last sync. - **The busiest hour of the last 7 days**: the real traffic of that hour, on every link. - **The busiest hour of a day**: one of the last 7 days. - **None**: only the traffic you add. RackTrace keeps the traffic of every port per hour from each sync of UniFi, Meraki or an SNMP scan, for 35 days. The history starts when RackTrace starts syncing, so right after linking a source only *Now* is there. With an hour from the history and no traffic of your own, the map shows that hour's load and the **Links** tab lists the fullest links. ### Suggested scenarios **Suggestions** in the top bar, and the empty workspace, offer ready-made scenarios made from your network and its history: - **The busiest hour**: the real traffic of the busiest hour. Which links get full? - **A weak spot fails**: the link or switch whose failure cuts off the most devices, at the busiest hour. - **The internet of a gateway fails**: the failover takes over when one is documented, with a check from a device at that site. - **50% more traffic**: at the busiest hour. - **A guest network stays apart**: checks that it reaches the internet and no other VLAN — a good scenario to [watch](https://docs.racktrace.io/network/simulation#sim-watch). A suggestion opens as a new scenario: change it, then save it. ### Options - **Include planned cables**: simulate the planned situation. - **Links that UniFi reports as down are down**. ### The map Choose a layer above the map: - **Network**: the switches, gateways and links. Failed devices are faded with a ✕, and switches cut off from the gateway have a red dashed outline. Above it is one **Internet**: every site with an internet connection of its own is connected to it with its WAN line and speed. A site that goes through another site (see [Sites and their internet](https://docs.racktrace.io/network/simulation#sim-sites)) has a line to that site instead: purple and dashed for a VPN, teal for MPLS, fibre or a leased line. A site-to-site VPN of the network plan is a purple dashed line between the gateways, thicker when traffic of the scenario goes through it. - **VLAN**: one VLAN at a time. Each link shows **U** (untagged) or **T** (tagged), grey when the VLAN isn't carried, **?** when one end isn't documented, and **!** when the two ends don't agree. The gateway of the VLAN is marked. - **Traffic**: the load. Each link is a pipe, and wider means faster. Traffic moves in lanes that keep right, one per direction; the thicker the lane, the fuller the link. Colours: green < 60 % orange 60–90 % red ≥ 90 %, and dark red when more is asked than fits. The bottleneck pulses with a label such as *200 % asked · +8 ms*. A switch flooded by a storm glows, and links blocked by spanning tree are thin grey dashed lines. A selected check or flow of traffic replaces the layer with its own way; the ✕ next to its name goes back. Click a device or a link to open it in the inspector. **Pause** stops the animation, and **Full screen** gives the map the whole window. After a run, the rack editor's **Simulation** button colours the cables by load and lets the traffic move along them. ### Results | Tab | What it shows | |---|---| | **Overview** | Four tiles (checks that pass, devices that lose the network, devices on another VLAN, traffic that gets through) and one line per finding. | | **Checks** | Each check without and with the changes, and where it stops. | | **Impact** | Each device traced to its gateway without and with the changes: who loses the network, who ends up on another VLAN, who gets it back. | | **Segmentation** | A matrix from each VLAN to each VLAN and the internet, for one protocol or any. A cell that the scenario changes is marked. Click a cell to add it as a check. | | **Firewall** | The rules of each gateway as the simulation reads them. | | **Traffic** | Per flow and direction: **Wanted**, **Gets**, without the changes, **Limited by**, **Latency**, **Loss** and **Quality**. | | **Links** | The load per link and direction. | | **PoE** | Per switch: its PoE budget, what its powered devices draw and what the scenario adds (see [below](https://docs.racktrace.io/network/simulation#sim-poe)). | | **Weak spots** | The switches and links whose failure cuts off the most devices, taking redundant links into account. **Add as change** puts that failure in the scenario. | | **Run** | The model version, the time, the fingerprint and the existing traffic of this run, its discovery sources with their last sync, and the earlier runs of the tenant (see [below](https://docs.racktrace.io/network/simulation#sim-run)). | ### What a result rests on Above the results, every run shows on what it rests: - **Model** — the version of the simulation engine. It goes up whenever a change to the engine changes an outcome, so two results of different model versions may differ for that reason alone. - **Fingerprint** — a code made from the whole outcome. The same scenario on the same network, with the same data from the sources and the same model, always gives the same fingerprint. - **Sources** — each discovery source of the tenant with the [freshness](https://docs.racktrace.io/concepts/source-and-freshness#freshness) of its last report, as on the device page: **Observed 12 min ago**, **Observed 7 h ago — old** (older than the threshold of its kind, 6 hours) or **Not observed yet** (never synced: unknown); the line turns amber when one is not fresh. A **Simulated** label opens the line. Old data is unknown, not down: a port that an old source reported down is not taken as down. - **Existing traffic** — now (and how old the live load is), an hour from the history, or none. The **Overview** tab ends with one block **Assumptions and uncertainties**: everything the run assumed instead of knowing — an old source, no load, a port speed or link aggregation that is not documented, an internet speed that is not set, an estimated PoE draw (13 W per access point, 7 W per camera), and every step of a trace that is not documented. A run is kept with its model version, fingerprint, sources and assumptions when you ask for it: you click **Run**, save the scenario, click **Run again** or make a report with **Report**. The runs that follow every edit are not kept, and only users who may change the documentation keep runs; the line above the results then says **kept**. A tenant keeps its last 100 runs. The **Run** tab lists them, with who ran them for users who may change the documentation. **Run again** opens what a run ran as a new scenario and runs it; the line above the results then says **Same outcome** or **Another outcome** — when the network, its sources or the model changed since. ### PoE The **PoE** tab shows, per switch, whether its PoE budget holds: - **Budget**: read from the notes of the switch or of its model, as *PoE budget 370 W*. The device library has it for the UniFi switches; for another switch, type it into its notes. - **Draws now**: what its access points and cameras draw. When discovery reports the watts per port, those are used; otherwise RackTrace estimates about 13 W for an access point and 7 W for a camera (*est.*). - **Added**: what the **Powered devices** changes of the scenario add. Over budget, the last ports get no power: those devices go down. The overview and the inspector of the switch show it too. ### Firewall The firewall step reads the rules from the [network plan](https://docs.racktrace.io/network/routing-and-firewall). Rules found by discovery from UniFi, FortiGate and Meraki carry their exact match (addresses, groups, services). Rules you typed in are read from their text, and a rule that can't be read counts as **probably**. What applies when no rule matches depends on the platform: UniFi zone-based firewall and classic rules each have their own defaults, a FortiGate denies, and Meraki allows. A gateway of unknown make gives **probably**. VLANs set to *isolated* or *no internet* in the network plan count as well. The **Firewall** tab lists each gateway with its platform and rules, and what stands out, such as a rule that is never reached. **Switch off** takes a rule out in the scenario only. ### Settings The key icon in the top bar opens the settings. They are the same for everyone in the tenant. - **Per gateway**: the internet speed (**Download** and **Upload**, what the provider delivers) and the **Routing / IPS throughput**, what the gateway routes with threat management on. - **Latency of the internet itself (ms)**: added to traffic that leaves through the WAN, for the quality of calls and video. - **Buffer per port (KB)**: a full link adds buffer ÷ speed of latency (1 MB at 1 Gbit/s ≈ 8 ms). - **Existing traffic: Mbit/s per session**: how much the current UniFi load competes with new traffic. - **WiFi per access point (Mbit/s)**: what one access point carries for all its clients together (600 when empty). - **Site-to-site VPN (Mbit/s)**: the most a tunnel carries; empty, the WANs of both sites decide. - **Calls and video first (QoS)**: voice and video do not queue behind a full link. - **Internet of this site** (with more than one site): *Its own internet connection*, or *Through …* another site. Then choose the **Link to that site** — a VPN on its own internet line, MPLS, its own fibre or a leased line — and its speed. See [Sites and their internet](https://docs.racktrace.io/network/simulation#sim-sites). - **Your own protocols**: an application of your own, such as an ERP client or a camera system. Give it a name, protocol and ports, how it behaves (**adapts**, **constant** or **small**), its rate and what it needs (latency, jitter, loss). It shows up in the protocol lists next to the built-in ones. ### Sites and their internet Customers with more than one site have their internet in one of two ways, and the simulation follows what you set per site in the [settings](https://docs.racktrace.io/network/simulation#sim-settings): - **Every site its own internet**, often with a site-to-site VPN between them. Traffic to the internet leaves at the site itself; traffic to the other site goes through the tunnel and uses the upload of one line and the download of the other. - **One internet for every site**: the branch offices go through the central site. Over a **VPN**, their traffic goes up their own line, into the central site and out through its line. Over **MPLS**, **fibre** or **a leased line**, it uses that link and its speed. Traffic between the sites uses the same link, also when no VPN is documented in the network plan. When the central site's internet fails, the sites that go through it lose it too. ### Saved scenarios **Save as…** gives the scenario a name. The list in the top bar opens another one. **Save** keeps the changes to an open scenario, the copy icon saves it as a new one, and the bin deletes it. Saved scenarios belong to the tenant, so colleagues see them too. Viewers can run scenarios but not save them. Scenarios of the earlier traffic simulation open as well. Their flows, storm, loop and failures become traffic and changes. ### Watching a scenario Save a scenario with checks, then click **Watch** in the top bar. From then on RackTrace runs its checks again by itself: - after every change in the documentation of the tenant and every sync of a discovery source (once things have been quiet for a minute), and at least once a day; - against the network as it is documented: the changes of the scenario are left out, so the checks guard the real network. The last run of a watched scenario is kept with it, with its model version, fingerprint, sources and assumptions. A check that fails becomes a [security alert](https://docs.racktrace.io/network/unifi-review#alerts): **High** when something that must not get through gets through, **Medium** when something that must get through is blocked. When the check passes again, the alert closes by itself. The button shows the last result, such as **Watched · 1 fails**; hover it for the time. **Open the scenario** on the alert brings you back to it. Only checks set to **Must get through** or **Must not get through** are watched. Click **Watched** again to stop; its open alerts are closed. ### Report **Report** in the top bar opens the scenario as a document for a change proposal: what changes, the outcome, the network map (and the load when there is traffic), the checks without and with the changes, the impact per device, the traffic and the PoE, and on what it rests: the model version, the fingerprint, the sources and the assumptions. **Print** it, or choose **Save as PDF** in the print dialog. ### Starting from a port Click **Simulate** next to a port in the rack editor's port panel, or in the port dialog on the device page. The simulation opens with a check from that port to the internet and 1 Gbit/s of traffic from it, and runs straight away. Anything already in the scenario is kept. ### When a device or a connection fails **What if it fails** opens the simulation with a new scenario in which only that part fails, and runs it: who loses the network, and which traffic takes another way. - On the device page of a switch, gateway, server or other device with connections. - In the port dialog on the device page, for a connected port: its connection fails, with the whole link aggregation it belongs to. - On an incident page, **What if this fails**: the device of the check fails, or for a port check its connection. An unsaved scenario that was open is replaced; a notice says so. --- ## UniFi > Connect UniFi Site Manager with an API key, link the sites to your customers, and add more UniFi accounts. URL: https://docs.racktrace.io/integrations/unifi Link UniFi to RackTrace to see what is behind every port, check the cabling and read the network configuration. An administrator connects UniFi once; after that everyone works on the [Discovery](https://docs.racktrace.io/integrations/discovery) page of their tenant. ### Connecting UniFi 1. Sign in at `unifi.ui.com` with the account that owns the consoles and go to **API → Create API key**. The key is read-only and covers every console of that account. 2. In RackTrace, open **Administration → Integrations** and the **UniFi** tab. Fill in a **Name** and paste the **API key**, then click **Connect**. 3. Click **Test connection**, then **Sync now**. The sites of the account appear under **UniFi sites**. 4. For every site, choose the **Tenant** (customer), the **Location** and, if one location has two environments, the **Network**. Only linked sites are read in detail. ![The UniFi tab of Integrations](https://docs.racktrace.io/assets/screens/integrations-unifi.webp "Administration → Integrations, UniFi: the account; the sites below it are linked to tenants and locations.") **Sync automatically** and **Refresh every (minutes)** (15 by default; 0 = only on **Sync now**) set how often RackTrace reads the sites. The key is stored on the server only; you only see its last four characters. **Keep the documentation in sync** (off for a new source and for a UniFi source from before this setting existed, until you switch it on): a linked switch, access point or gateway takes over its serial number, IP and MAC, and per port its own name, VLANs, PoE setting, whether it is switched off and the link aggregation — when it is linked and after every sync, also while it is offline. UniFi is leading. See [The documentation follows the network](https://docs.racktrace.io/integrations/discovery#docs-sync). Consoles in a different UniFi account: click **Add another UniFi account** at the bottom of the tab and give it its own name and key. The console needs UniFi OS 5.0.3 or newer. --- ## NetBird > Connect a customer's NetBird account with a read-only token: its peers in Discovery, its routing peers monitored. URL: https://docs.racktrace.io/integrations/netbird Link a customer's NetBird account to RackTrace to see every peer in [Discovery](https://docs.racktrace.io/integrations/discovery) and to monitor the peers that route into the customer's network. An administrator connects NetBird once per account; after that everyone works on the Discovery page of their tenant. This is about your customer's own NetBird. It has nothing to do with how you reach RackTrace itself. ### What you need RackTrace reads NetBird with a **personal access token** of a **service user** with only read rights: 1. In the NetBird dashboard, go to **Team → Service Users** and click **Create service user**. Give it a name such as *RackTrace* and the role **Auditor** — that role can see everything and change nothing. 2. Open the service user and click **Create token**. Pick an expiry date that suits you and copy the token (it starts with `nbp_`). NetBird shows it only once. Use the Auditor role, not Admin: RackTrace only reads, and a token that can only read does no harm if it ever leaks. When the token expires, the source shows an error; create a new token and paste it in. ### Connecting NetBird 1. In RackTrace, open **Administration → Integrations** and the **NetBird** tab. 2. **API address**: leave `https://api.netbird.io` for the NetBird cloud. A customer with its own NetBird server fills in the address of that server (`https://netbird.customer.com`; with or without `/api`). 3. Paste the token under **Access token** and click **Connect**. 4. Click **Test connection**: it says how many peers the token can see. Then click **Sync now**. The account appears as one line below. 5. Choose the **Tenant** (customer), the **Location** and, if needed, the **Network** for the account. Only a linked account is read in detail. The token is stored encrypted on the RackTrace server. It is never shown again — not even its last characters — and it never appears in a log, an export or a mail. #### A NetBird server on a private address RackTrace reads NetBird over the internet. On racktrace.io — and on any RackTrace server with several organizations — the API address must be public: a NetBird server on a private address (such as `10.0.0.5`, `192.168.1.20` or a `.local` / `.lan` name) is not reachable from RackTrace and is refused, as is a link-local address such as a cloud metadata address. - Usually this is no problem: the management server of a self-hosted NetBird is already public, because the peers outside the office connect to it. Give RackTrace that same public address. - Is the server only reachable inside the customer's network? Then RackTrace cannot read it (yet): the RackTrace agent inside the network does not read NetBird. Make the management API reachable on a public HTTPS address, or keep the customer on the NetBird cloud. - A RackTrace installation of your own, with one organization, may use a private address. **Refresh every (minutes)** (15 by default; 0 = only on **Sync now**) sets how often RackTrace reads the peers. A customer with more than one NetBird account: click **Add another NetBird account**. ### What RackTrace reads RackTrace only sends GET requests. It reads: | What | From NetBird | |---|---| | Every peer | Name, NetBird IP, connected or not, last seen, operating system, NetBird version, groups | | Routing peers | Which peers route into a network: named in a route or as a router of a network, directly or through one of their groups | | The network side | The networks the routing peers make reachable (routes and network resources), as routes in the [network plan](https://docs.racktrace.io/network/network-plan) review | It does **not** keep the public address a peer connects from — for a laptop, that is where its user is — and it does not read setup keys, access policies, DNS settings, users or tokens, and it never changes anything in NetBird. At most 5,000 peers are read per sync; NetBird sends its lists in one answer, so each answer is limited in size and time (25 seconds). ### Peers in Discovery Every peer appears on the Discovery page of the tenant: - A **routing peer** is network equipment: category **Router**. - A peer with the NetBird desktop app, or with macOS, Windows 10 / 11, iOS or Android, is an **end device** (a laptop, desktop or phone). End devices are listed with the clients, not with the devices: they give no **New device** notice and no entries in **Changes** (unless linked to a documented device) — someone's laptop going online and offline is not a change in the network. - Any other peer — a Linux or Windows server without routes — is a **server**, listed with the devices. The category is a best guess from what NetBird reports; you can change it when you import the device. NetBird has no **Keep the documentation in sync**: the IP of a peer is its NetBird address, not the management IP of the device in your documentation, so a linked device never takes it over. ### Monitoring As with the other sources, [monitoring](https://docs.racktrace.io/network/monitoring) watches network equipment by default: the **routing peers**. Laptops, phones and servers are shown in Discovery but are not monitored. - **Connected** and **last seen** are the state NetBird reports. A peer that is connected is online. - NetBird drops a peer's connection the moment its line breaks — a laptop that goes to sleep, a router that changes its internet line. So a peer counts as **offline** only when it has not been seen for **5 minutes**. Until then its state is unknown, and a short reconnect is never an incident. - Between two syncs, RackTrace asks NetBird for the state of the peers every 2 minutes (one call), so a routing peer that goes offline is noticed within minutes. - Where the RackTrace scanner sees the same device, the scanner measures it; NetBird measures where there is no scanner. For [source and freshness](https://docs.racktrace.io/concepts/source-and-freshness), NetBird is a **controller API**: the NetBird management server holds the live connection of every peer. ### When something is wrong The error is shown on the source, under **Last sync**: | Message | What to do | |---|---| | *NetBird refused the token: it is wrong, expired or revoked* | Create a new token for the service user and paste it in. | | *NetBird refused access … use a service user with the Auditor role* | The token's user may not read the peers: give the service user the Auditor role. | | *… has no NetBird API at this address* | Check the **API address**: the cloud is `https://api.netbird.io`; for an own server, the address of the management server. | | *Cannot reach NetBird …* or *did not answer in time* | The server is down or not reachable from RackTrace. | --- ## NetBox > Move from NetBox 3 or 4 to RackTrace — sites, locations, racks, devices with their ports, patch panels and cables in one import, through the NetBox API or from exported files. URL: https://docs.racktrace.io/integrations/netbox Moving from NetBox? Bring its documentation over in one step: sites, locations, racks, devices with their interfaces, console and power ports, patch panels with their front and rear ports, and the cables between them. RackTrace reads NetBox 3.x and 4.x — through the NetBox API, or from files exported from NetBox when RackTrace cannot reach it. You see a preview first and choose the sites and the tenant they go into. ### What comes over | NetBox | RackTrace | |---|---| | Site | Site, with its physical address and description. A site of the same name in the tenant is used. | | Location with racks or devices of its own, or without locations below it | Room | | The location above that room | Floor — "Floor 2" becomes floor `02`, "Level -1" floor `-1` | | Locations higher up (a building, a campus) | The **Building** of the room | | No location | Room "Main room" on floor `00` "Ground floor" | | Rack | Rack with its height (at most 60U), asset tag and facility ID. Racks that count their units from the top, or start at another unit, are converted. | | Device | Device in its rack at its U, or in its room. Name, status, serial number, asset tag, primary IP, description and comments. | | Device type | The template of the [device library](https://docs.racktrace.io/features/device-library) of the same manufacturer and model (or part number); otherwise a generic template of its kind and height, such as **Server 1U** or **Switch 48x GbE**. See [Device types and ports](https://docs.racktrace.io/integrations/netbox#netbox-templates). | | Device role | Category (switch, patch panel, server, PDU …) | | Interface | Port with its type (RJ45, SFP+ …), speed, PoE, label and description; switched off and link aggregation (LAG) as in NetBox; management only becomes the role **Management** | | Console port, console server port | Port (Console, DB9, USB) | | Power port, power outlet | Port (Power C14, C13, Schuko …) | | Front port with its own rear port | A pass-through pair, as on a patch panel: a trace runs through it | | Cable | Cable between the two ports, with its label, type, colour, length (converted to metres) and *planned* when it is planned in NetBox | A port name with `/` gets `-` instead (`Gi1/0/1` becomes `Gi1-0-1`), as everywhere in RackTrace. ### What does not come over - Virtual, wireless and LAG interfaces themselves (a LAG's members do come, with the LAG's name), VLANs, prefixes and IP addresses (only a device's primary IP), VRFs. - Circuits and power feeds, and the cables to them. Cables to devices of sites you do not import. - Modules and module bays, device bays: a device in a device bay (a blade) goes into the room, with a note where it was. - Virtual machines, clusters, contacts, tags, custom fields, journal entries, images. - A front port that shares a rear port with other front ports (an MPO cassette: one rear port with 12 positions) comes over without the internal link — the preview says which. A device on a U that is already taken, or above the top of the rack, goes into the room of its rack, with a note in its notes. The preview lists all of these. ### From the NetBox API 1. In NetBox, make an API token. NetBox 4: **Admin → API Tokens → Add** (or your user menu → **API Tokens**); NetBox 3: your user menu → **API Tokens**. Reading is enough: leave **Write enabled** off. 2. In RackTrace, open **Export & reports** in the tenant you want to import into (as an administrator) and click **Import from NetBox**. 3. Choose **NetBox API**, fill in the **NetBox address** — the address you open NetBox with, such as `https://netbox.example.com` — and paste the **API token**. Click **Next**. 4. Choose the sites. Every site shows its NetBox tenant, so **Only …** picks the sites of one customer. 5. Under **Import into**, choose a tenant, or **New tenant …** with a name (the name of the NetBox tenant when the sites have one). 6. Click **Preview**, check it (see [The preview](https://docs.racktrace.io/integrations/netbox#netbox-preview)) and click **Import**. ![The sites of NetBox, the ones of one customer chosen](https://docs.racktrace.io/assets/screens/netbox-import.webp "Export & reports → Import from NetBox: the sites with their NetBox tenant, into a new tenant.") The token is used for this import only: RackTrace does not store it, and it is not in the history. RackTrace reads NetBox itself, page by page — a large NetBox takes a while. > **Can RackTrace reach your NetBox?** > > On racktrace.io, RackTrace reads NetBox over the internet: the address must use **https** and be reachable from the internet. RackTrace never connects to an internal address (`10.x`, `192.168.x`, `localhost` …) and does not follow redirects. Is your NetBox only reachable inside your network? Use [files](https://docs.racktrace.io/integrations/netbox#netbox-files) instead. On your own RackTrace server (one organization) an internal address works too, and `NETBOX_ALLOW_HTTP=1` allows `http://`. ### From files For a NetBox that RackTrace cannot reach, export its lists as JSON and choose **Files** in the dialog. RackTrace reads one file per list of the NetBox API, or one file with all lists; which list a file holds, it sees from its content. **From the browser**, signed in to NetBox: open each of these addresses and save the page (`Ctrl`+`S`) as a `.json` file: ``` https://netbox.example.com/api/dcim/sites/?limit=0&format=json https://netbox.example.com/api/dcim/locations/?limit=0&format=json https://netbox.example.com/api/dcim/racks/?limit=0&format=json https://netbox.example.com/api/dcim/device-types/?limit=0&format=json https://netbox.example.com/api/dcim/devices/?limit=0&format=json&exclude=config_context https://netbox.example.com/api/dcim/interfaces/?limit=0&format=json https://netbox.example.com/api/dcim/front-ports/?limit=0&format=json https://netbox.example.com/api/dcim/rear-ports/?limit=0&format=json https://netbox.example.com/api/dcim/console-ports/?limit=0&format=json https://netbox.example.com/api/dcim/console-server-ports/?limit=0&format=json https://netbox.example.com/api/dcim/power-ports/?limit=0&format=json https://netbox.example.com/api/dcim/power-outlets/?limit=0&format=json https://netbox.example.com/api/dcim/cables/?limit=0&format=json ``` NetBox gives at most 1000 objects per page (its `MAX_PAGE_SIZE`). When a list has more — the interfaces, often — save the next pages too with `&offset=1000`, `&offset=2000` …; RackTrace puts the pages of a list together. Add `&site=` to export one site. **With a script**, for a large NetBox: this script (Python 3, nothing to install — every NetBox server has it) writes all lists into one file, `netbox-export.json`: ```python #!/usr/bin/env python3 """Writes the NetBox lists RackTrace imports into one file, netbox-export.json. python3 netbox-export.py https://netbox.example.com [site slug ...] Without site slugs: every site. A self-signed certificate: NETBOX_INSECURE=1 python3 netbox-export.py ...""" import json, os, ssl, sys, urllib.parse, urllib.request base, token, sites = sys.argv[1].rstrip('/'), sys.argv[2], sys.argv[3:] auth = ('Bearer ' if token.startswith('nbt_') else 'Token ') + token tls = ssl._create_unverified_context() if os.environ.get('NETBOX_INSECURE') else None def get(path, params=()): req = urllib.request.Request(f'{base}/api/{path}/?{urllib.parse.urlencode(list(params))}', headers={'Authorization': auth, 'Accept': 'application/json'}) with urllib.request.urlopen(req, context=tls) as r: return json.load(r) data = {'netbox-version': get('status')['netbox-version']} for name in ['sites', 'locations', 'racks', 'device-types', 'devices', 'interfaces', 'front-ports', 'rear-ports', 'console-ports', 'console-server-ports', 'power-ports', 'power-outlets', 'cables']: params = [('slug' if name == 'sites' else 'site', s) for s in sites] if name != 'device-types' else [] if name == 'devices': params.append(('exclude', 'config_context')) rows, offset = [], 0 while True: page = get(f'dcim/{name}', params + [('limit', 1000), ('offset', offset)]) rows += page['results'] offset += len(page['results']) if not page.get('next') or not page['results']: break data[name] = rows print(f'{name}: {len(rows)}', file=sys.stderr) with open('netbox-export.json', 'w') as f: json.dump(data, f) print('Written: netbox-export.json — import it in RackTrace under Export & reports → Import from NetBox → Files', file=sys.stderr) ``` Save it as `netbox-export.py` and run it with the address and a token, for example `python3 netbox-export.py https://netbox.example.com 0123abcd… ams-hq rtm-dc` for two sites. The files together may be 40 MB at most; import a large NetBox a few sites at a time. ### The preview The preview shows what the import does, before anything is made: - **How many** sites, floors, rooms, racks, devices, ports and cables — new, and existing ones that are used. - **Not imported**: virtual interfaces, cables to circuits and power feeds, cables to devices of sites you did not choose. - **Device types**: the ones that are not in the library, with the generic template each gets (or **none — own ports only**), and the ones found in the library. - **To check**: a device on a U that is taken or above the rack, a rack higher than 60U, a device in a device bay, front ports that share a rear port, a cable with several ends on one side that do not pair up, a device that already exists. **Import** is not possible when the import would go over the limits of your plan (racks, devices or tenants) or when a new tenant's name is taken. ### Importing - Only **administrators** import, as with the JSON import of a tenant. - The import is one step: all of it or, when something goes wrong, nothing. - Every site, floor, room, rack, device and cable gets its own entry in the [history](https://docs.racktrace.io/features/history-and-search), as when made by hand; one more on the tenant says what came from which NetBox (version and address). - **Again into the same tenant**: sites, floors, rooms and racks of the same name are used, and a device that already exists — the same name in its room, or the same serial number — is left as it is. Cables to it are connected where its ports are free; cables that are already there are skipped. So you can import one site after the other, or run the import again after NetBox changed — it adds what is new and changes nothing that exists. - The plan of your organization limits the number of racks, devices and tenants; the preview says when the import would go over it. ### Device types and ports A device type is matched to a template of the library by its manufacturer and its model or part number — "C9300-48P", "USW-Pro-48" — and the manufacturer may be written differently (Cisco Systems, HPE / Aruba, APC by Schneider Electric). A template of the tenant itself comes first. The device then has the template's ports with their real layout on the faceplate, and each NetBox port is matched to one of them: by its name (`GigabitEthernet1/0/1` is `Gi1-0-1`), by its numbers (`Port 1` is `1`), or what is left of one port type in order. Ports NetBox has that the template does not are added. A device type that is not in the library gets a generic template of its kind and height, for its look in the rack — **Patch Panel 24x RJ45 Cat6**, **Fiber Panel 12x LC Duplex**, **Server 2U**, **PDU 0U 24x C13** — and its own ports exactly as NetBox has them, with the manufacturer and model of NetBox. When there is no generic template of that kind and height (a 7U blade chassis), the device has no template and only its own ports. To get the look right later, choose a template on the device page; or [add the model to the library](https://docs.racktrace.io/features/device-library) before the import, so the import finds it. --- ## JSON sources > Let any tool deliver its data to RackTrace in an open JSON format, also from inside a customer’s network. URL: https://docs.racktrace.io/integrations/json-sources Tools other than UniFi can deliver the same information to RackTrace in an open JSON format. ### Push and pull sources Any tool can deliver the same data in an open JSON format. On the **JSON** tab: - **New push source**: the tool sends its data to RackTrace. Give it a name and click **Create**. Copy the token straight away; it is shown only once. The tool sends `POST /api/ingest` with `Authorization: Bearer `. - **New pull source**: RackTrace fetches the data from an HTTPS **URL**, optionally with a **Bearer token**, every **Refresh every (minutes)**. Each scope in the JSON appears under **Scopes**; link it to a tenant, location and network like a UniFi site. The card **Format “racktrace-discovery” v1** describes the format with an example. Each delivery replaces the earlier data of that scope. A port can also say how it is set: `label` (its own name), `poe_mode` (`on`, `off`, `passive 24V`), `enabled` (`false` = switched off) and `lag` (e.g. `LAG 49+50`). Tick **keep in sync** at the source and linked devices take these over with every delivery, together with serial, IP, MAC and the VLANs (see [The documentation follows the network](https://docs.racktrace.io/integrations/discovery#docs-sync)). A delivery can say when the tool observed the network: `observed_at` (an ISO time) for the whole delivery or per scope. RackTrace keeps it next to the time it received the delivery in [Changes seen in the network](https://docs.racktrace.io/integrations/discovery#changes). A time more than 5 minutes ahead or more than 24 hours ago is refused; without it, the time of receipt is used. Is the tool only reachable inside the customer's network? Use the [RackTrace agent](https://docs.racktrace.io/integrations/json-sources#agent). ### The RackTrace agent for sources inside a network RackTrace cannot reach addresses inside your network, such as an inventory server or an export on a file server. The agent can: it runs on a computer or server there, fetches the JSON and pushes it to a push source. It only needs outgoing HTTPS, so nothing has to be opened in the firewall. 1. Create a **push source** and copy its token. The token dialog also shows an `agent.json` with the token filled in. 2. In the card **Agent for addresses in your own network**, click **Download the agent** and put `agent.json` next to it. It is one file and needs Node.js 18 or newer. 3. Run `node racktrace-agent.mjs --check` to test the internal address and the token without sending anything. 4. Run it as a service (`node racktrace-agent.mjs`, systemd or Docker), or every 15 minutes with `--once` from cron or Task Scheduler. The source then shows the agent, its version and its last contact. When the agent cannot reach the internal address, that error is shown with the source. --- ## Domotz > Connect Domotz, link collectors to your customers, link Domotz devices and compare the Domotz map with the cabling. URL: https://docs.racktrace.io/integrations/domotz With Domotz connected, documented devices show whether they are online, and RackTrace compares the Domotz network map with the documented cabling. ### Connecting Domotz 1. In the Domotz portal, go to **Settings → API keys** and create a key; read access is enough. Note the **API Key Endpoint** shown with it, which depends on your region. 2. In RackTrace, open **Administration → Integrations**, tab **Domotz**. Paste the **API Key Endpoint** and the **API key**. 3. Click **Test connection**, then **Save**, then **Sync now**. 4. Under **Domotz collectors**, choose for every collector the **Tenant**, optionally a **Site**, the room to **Import into** and a **Network**. Only linked collectors are synced (every 10 minutes by default). ### The Domotz page Open **Network → Domotz** (shown once Domotz is connected). - **Devices in Domotz**: filter with **All**, **Suggestions**, **Not linked**, **Linked**, **Offline** and **Ignored**. - **Accept** takes a suggestion, or **Link all suggestions** takes them all; empty fields (IP, MAC, serial) are filled from Domotz and nothing is overwritten. - The link icon links a device by hand. - **Ignore** hides phones, guests and other devices you don't document. - **Import … selected…** creates the ticked devices in a **Room**, each with a LAN port, linked straight away. Patch the LAN port afterwards. - **Network map vs. cabling** compares Domotz' topology with the documented cable paths: - **check**: documented and both online, but Domotz sees no connection, so possibly a broken or wrongly patched link; - **missing**: Domotz sees a connection that isn't in the cabling; - **planned**: Domotz sees it, but it is still planned; - **standby**: connected another way (redundant, LAG or STP standby link), which is normal; - **offline**: not checked, because a device is offline. Linked devices show their live online / offline status on the device page and in the rack editor. --- ## Discovery > Link the devices that UniFi or another source reports, apply updates, check the cabling and document endpoints. URL: https://docs.racktrace.io/integrations/discovery The **Discovery** page of a tenant brings what the live network reports together with the documentation. ### The Discovery page Open **Network → Discovery**. The tiles at the top count linked devices, suggestions, updates and cabling problems; click one to jump to it. The tabs below them are **Devices**, **Updates**, **Cabling check**, **Endpoints**, **Wired clients**, [Deviations](https://docs.racktrace.io/integrations/discovery#deviations) and [Changes](https://docs.racktrace.io/integrations/discovery#changes). **Sync now** reads the sources again, and **Sources** lists them with their last sync. ![The Discovery page with the devices UniFi reports](https://docs.racktrace.io/assets/screens/discovery.webp "The Discovery page: what the network reports, linked to the documented devices.") #### Devices - Every device the network reports, with status, IP, MAC / serial and the RackTrace device it is linked to. Filter with **All**, **Suggestions**, **Not linked**, **Linked**, **Offline** and **Ignored**. - **Accept** links a suggestion (matched by MAC, serial, IP or name). **Link all suggestions** accepts them all. Nothing on the devices themselves changes; with a source that [keeps the documentation in sync](https://docs.racktrace.io/integrations/discovery#docs-sync), the linked device takes over its serial number, IP, MAC and port configuration right away. - The link icon links a device by hand; **Unlink** undoes it. - **Import** (or tick several and **Import … selected…**) creates the device at the location of the UniFi site, with a matching library model when there is one. Under **Place**, let RackTrace choose the room (where its cable leads, or next to its uplink switch) or put all of them in one room. - **Ignore** hides devices you don't document. #### Updates Lists the management IP, MAC, serial and name that differ from what the network reports, from → to. Tick what to take over and click **Apply** or **Apply all ticked**. Names are not ticked by default. With a source that keeps the documentation in sync, IP, MAC and serial follow by themselves and only names show up here. ### The documentation follows the network **Keep the documentation in sync** is a setting of each source under **Administration → Integrations**. It is off for every new source, whatever its type: what a source observes reaches the documentation through review (Updates, the cabling check, the network plan review) until an administrator switches this on for that source. A source that was connected before this setting existed stays off as well. Switching it on asks for a confirmation, because from that moment the source is leading and the linked devices take over its configuration at once. With it on, a linked network device (switch, access point, gateway) takes over what the source reports: - when it is linked or imported, and after every sync; - also while the device is offline: the controller keeps its settings, so a port renamed or reconfigured meanwhile is updated too. | What | Taken over | |---|---| | Device | **Serial**, **Management IP** and **MAC** (the name stays a choice under [Updates](https://docs.racktrace.io/integrations/discovery#updates)) | | Label | The port's own name in the source, such as *Printer reception*. A default name such as *Port 12* leaves the label alone. | | VLANs | The port profile when the port uses one unchanged, otherwise the port's own VLANs. A VLAN or profile the [network plan](https://docs.racktrace.io/network/network-plan) does not have yet is added from the source's configuration, in the network of the site. | | PoE setting | On, off, passive 24V or passthrough. *Off* is only set on a port that offers PoE. | | Switched off | A port that is disabled on the switch. | | Link aggregation | The ports that form one link, such as *LAG 51+52*. | The source is leading: a change to these fields in RackTrace is undone at the next sync, and the port dialog says so. What the source does not report stays as documented, and nothing is ever written to the source. Every change is in the device's **History**, under the person who linked the device or under the source. > **Note** > > Switch the setting off for a source whose controller is not kept up to date. Differences in IP, MAC and serial then wait under **Updates**, and the VLANs of switch ports under [Configuration from UniFi](https://docs.racktrace.io/network/unifi-review). ### The cabling check The **Cabling check** tab compares every live link with the documented cable path. Uplinks and LLDP give the exact port on both sides; wired clients give the switch port. **Check again** runs it once more. ![The cabling check](https://docs.racktrace.io/assets/screens/cabling-check.webp "The cabling check compares every live link with the documented cable path.") | Result | Means | What to do | |---|---|---| | confirmed | The live link matches the documentation. | Nothing. | | mismatch | Another device is on the port than the documented far end. | Fix the cable in RackTrace, or re-patch on site. | | wrong port | The right device, but another port on it. | Move the cable to the right port. | | incomplete | The documented path stops at a free outlet or patch port. | Complete the cable path, or see [Endpoints](https://docs.racktrace.io/integrations/discovery#endpoints). | | planned | The link is live, but the cable is still planned. | Clear **Planned** on the cable. | | down | A documented link between network devices is down. | Check the cable and both devices. | | missing | A live link or client with no cable documented. | Document the cable. | | unknown | A neighbour that isn't linked to a RackTrace device yet. | Link it on the **Devices** tab. | Each item has an **open** link to the switch, and the status of its [deviation](https://docs.racktrace.io/integrations/discovery#deviations). Switch ports are matched by number. ### Endpoints and wired clients The **Endpoints** tab lists clients that a switch sees on a port whose documented cable ends at a free outlet or patch-panel port: - **Create & connect** creates the device (name, IP and MAC from the network) with a LAN port and the cable to that free port. **Create & connect all** does them all. - **Connect**: the device already exists in RackTrace; only the cable is added. - **Link to …**: a device is already documented at the end of the cable; the client is linked to it. **Wired clients** lists every wired client with its IP, MAC, network and VLAN, switch port and linked RackTrace device. #### Hosts without SNMP A scanner job looks at the other addresses of its ranges in two ways: a TCP sweep (a host that answers or refuses a connection on one of the ports) and, from scanner version 1.6.0, a ping (ICMP) for what answered neither. A host that only answers ping appears as a client, never as network equipment. The ping runs at most 64 at a time and covers at most 4,096 addresses per job and run. All jobs of a scanner that run in the same round share 30 seconds of pinging, so that pings do not hold up the monitoring checks of that scanner; when the time is used up, the remaining jobs of that round skip the ping and say so in their notes. A larger range (such as a /16) is pinged in parts: a scanner running as a service continues where the previous run of the job stopped, and the job says in its notes how many addresses were left. A scanner started with `--once` (for instance from cron), or one that was restarted, begins at the start of the range again. If the scanner cannot run `ping` at all (no such program, or no right to send ICMP), the job says so in its notes instead of reporting an empty network. Only addresses inside the ranges of the job are ever pinged. A scanner older than 1.6.0 simply does the TCP sweep, as before. For a host without SNMP the **manufacturer** comes from the first half of its MAC address (the IEEE registry of prefixes), so a printer or camera shows as, for instance, *Axis Communications* instead of an empty line. It appears on the **Wired clients** tab and on the device page, in the Discovery line, when the device has no manufacturer of its own. A random (private) MAC address, as some phones use, has no manufacturer; neither has a host whose MAC address the scanner cannot see (a host in another subnet). #### Updating a scanner From scanner version 1.7.1, a scanner updates itself: RackTrace says which agent it carries, and the scanner installs a newer version only when it is signed with a key the scanner trusts. That works when the environment signs its agent; otherwise the scanner card says that a new version is available. A scanner older than 1.7.1 needs one update by hand, after which it keeps itself up to date. A scanner that cannot update itself says what to do for the way it was installed: | Installed as | What to do | |---|---| | Docker | Pull the image again and restart the container. | | Windows | Run the new installer (MSI) over the old one. | | Appliance | Deploy a new appliance image; the appliance has no manual update step. | | Script | Download the new `racktrace-agent.mjs` and restart the agent. | The Docker image to pull is shown in the installation steps of **Integrations → Scanner**. On a test environment that is the `uat` image; the appliance images exist for production versions only, so a test environment offers Windows, Docker and the script. ### Deviations with a status The cabling check and the [network plan review](https://docs.racktrace.io/network/unifi-review) are compared again after every sync. What they find is kept as a **deviation** with a status, on the **Deviations** tab: | Status | Means | |---|---| | Open | Found, nobody has decided anything yet. | | Accepted | Someone knows about it: the documentation is being adapted through the review, or the network will be put right. | | Ignored | Deliberately left as it is. A reason is required, and it is kept with the deviation. | | Resolved | The next check no longer finds it — set by RackTrace, never by hand. | - A deviation keeps its status from sync to sync: the same port, link, VLAN or object is the same deviation, never a new one each time. - A decision holds for what it was made on. When the documented or the observed value changes, an accepted or ignored deviation is **open** again. When a resolved deviation comes back with the same values, its decision comes back too. - What RackTrace could not see this time resolves nothing, judged per site: a switch that is offline, a read in which a site delivered no port details (no links or VLANs per port — for example when only UniFi's official API answered), or a part of the configuration that site no longer reports. Another site reporting the same thing does not count for it. What a read cannot judge does not appear in the list either, until a read can; a documented link that is down needs only the link state of its port, and a read that does not report that state resolves nothing. - Filter on status, source and kind; **Accept**, **Ignore…** and **Reopen** work on one row or on the ticked ones. Deciding on the cabling needs the right to change cables, on the network plan the right to change the network plan; anyone with access to the tenant can read the list. Every decision is in the history. - **Check now** compares again without a sync (it needs the right to change cables or the network plan). The cabling check and the network plan review show the status next to each finding, and a linked device's page shows its own deviations. With more than 500 deviations that are not resolved, the line above them says the status is shown for the first 500 only. - Only the errors and warnings of the cabling check are kept (not the hints about undocumented clients). At most 5,000 open per tenant; resolved deviations are kept 30 days, and one that no check has seen for 90 days is removed. ### Changes seen in the network The **Changes** tab keeps what the sources reported differently from their previous report, newest first. It is the record of what happened in the network, for example to find out what changed before a fault; nothing here needs handling. | Change | Logged when | |---|---| | New device, no longer reported, reported again | A network device appears, disappears or comes back. Clients only when they are linked to a RackTrace device. | | Online / offline | The source reports another status for a device. | | Link up / down | A port's link changes. | | Settings | A device's name, IP address or firmware; a port's untagged or tagged VLANs, PoE, label, link aggregation or whether it is switched on. | - **Observed** is when the source saw it: the moment RackTrace started reading a UniFi, Meraki, FortiGate or Auvik source, the time a push says it observed (`observed_at`, see [the JSON format](https://docs.racktrace.io/integrations/json-sources#json-setup)) or the start of a scanner job. **Received** is when RackTrace stored it. *Before: the report of …* says when the old state was last reported: the change happened in between. - The first report of a source is the starting point: it is compared with nothing, so it adds no changes. A value a source does not report (no status, no link state) is no change either, and neither is a port's link while its device is offline. - A port or device that keeps changing gets at most three lines a day; after that its changes are counted on the latest line (*link changed 8 times, now up*). - Filter on **Devices** or **Ports**, and on one source when the tenant has several. **Older** loads the next part. - Changes are kept 90 days, at most 20,000 per tenant. A report with more than 1,000 changes at once keeps the first 1,000 and one line with the number left out. Changes in the network configuration itself (port forwards, firewall rules, WiFi, VPN) are judged as [security alerts](https://docs.racktrace.io/network/unifi-review) instead. ### Live information on devices and racks - The device page gets a **Discovery** line (source, firmware, update available) and a **Domotz** line, and the port list a **Live** column: link up or down, speed, PoE and what is behind the port. - A linked device's page shows its own **Deviations** (see [Deviations with a status](https://docs.racktrace.io/integrations/discovery#deviations)) and **Network changes** (see [Changes seen in the network](https://docs.racktrace.io/integrations/discovery#changes)). - The port dialog shows **Live from the network** with the neighbours (client, LLDP, uplink). - In the rack editor, **Live** puts a green or grey dot on every reported port, and the port tooltip and port panel show the same details. - The floor plan shows online / offline and WiFi clients per access point (see [Live status on the plan](https://docs.racktrace.io/features/floor-plans#plan-live)). --- ## Ticket systems (HaloPSA, Autotask, ConnectWise, TOPdesk) > Connect HaloPSA, Autotask, ConnectWise PSA or TOPdesk — tickets for security alerts, offline devices and cabling faults, tickets on the device, rack and site pages, and devices as assets. URL: https://docs.racktrace.io/integrations/ticket-systems Connect the ticket system your service desk works in, and RackTrace: - makes a **ticket** when it sees a problem — a security alert, a device that goes offline, a fault in the cabling check — at the client the tenant is in your ticket system, **one ticket per problem**, with a note on it when the problem is gone; - shows the **tickets** on the dashboard, site and device pages and in the rack editor, with **Create ticket** (the path, location and the trace of a port go in it); - keeps the **devices as assets** (configuration items) in the ticket system, with a link back to RackTrace. Supported: **HaloPSA**, **Autotask** (Datto / Kaseya), **ConnectWise PSA** (ConnectWise Manage) and **TOPdesk**. One ticket system per organization. ### Connecting the ticket system 1. Create an API sign-in in the ticket system — see the steps per system below. 2. In RackTrace, open **Administration → Integrations**, tab **Tickets**. Choose the **System** and fill in the address and the sign-in. 3. Click **Test connection**, then **Save**. 4. Under **Defaults**, choose how new tickets are made (ticket type, board or queue, the priorities for *High*, *Medium* and *Low*), when problems become a ticket, and the asset type for assets. Click **Save**. 5. Under **Tenants**, choose for every tenant the **Client** it is in the ticket system. When a client has the same name, **Link to …** does it in one click. The secret parts of the sign-in are stored encrypted on the RackTrace server and never shown again or sent to browsers. **Remove sign-in** removes them. Choosing another **System** removes the links of the tenants and of the assets; the tickets made so far stay in the lists. > **On your own server** > > RackTrace on your own server does not know the address your colleagues open it at. Fill in **Address of RackTrace (the link back in a ticket)** under **Defaults** (or set `RACKTRACE_PUBLIC_URL` on the server), so every ticket links back to the device, the security alerts or the cabling check. #### HaloPSA 1. In HaloPSA, create an agent for RackTrace under **Configuration → Teams & Agents → Agents** and tick **Is an API-only Agent**. Give it access to your clients. 2. Go to **Configuration → Integrations → Halo API**, click **View Applications** and add an application: **Authentication Method** *Client ID and Secret (Services)*, **Login Type** *Agent*, **Agent to log in as** the agent of step 1. On **Permissions** tick `read:customers`, `read:tickets`, `edit:tickets`, `read:assets` and `edit:assets` (or `all`). 3. In RackTrace fill in the **HaloPSA address** (`https://yourcompany.halopsa.com`), the **Client ID** and the **Client secret**. **Tenant** can stay empty: RackTrace looks it up (it is under *API Details* in HaloPSA). Per tenant, **Settings** chooses the **Site** of the client for new tickets and assets (by default the client's main site). Under **Defaults** choose the **Ticket type**, the **Outcome** of the notes RackTrace adds (by default *Private Note*), and for assets the **Asset type**: the device name goes in its key field. The serial number, MAC address and management IP go in the asset fields with those names, or the ones you choose. **Counts as closed** ticks the statuses at which a ticket is done for RackTrace — *Closed* by default; tick *Pending Closure* as well when a ticket waiting for the user to confirm counts as done. #### Autotask 1. In Autotask go to **Admin → Organization Settings & Users → Resources/Users (HR) → Resources/Users**, click **New** and then **New API User**. 2. Choose the security level **API User (system) (API-only)**, click **Generate Key** and **Generate Secret**, and under **API Tracking Identifier** choose **Custom (Internal Integration)** with the name *RackTrace*. 3. In RackTrace fill in the **API user name** (exactly as Autotask shows it), the **Secret** and the **API tracking identifier**. There is no address to fill in: RackTrace looks up the zone of the user. Under **Defaults** choose the **Queue** where new tickets land (most Autotask databases need one), the status, category, type, issue type and source of new tickets, and the note type and visibility of the notes RackTrace adds. Autotask needs a **Product** for every configuration item: choose one under *Assets* — for example make a product *Network device (RackTrace)*. **Counts as closed** ticks the statuses at which a ticket is done for RackTrace — *Complete* by default (the status that completes a ticket in Autotask); tick others, such as *Cancelled*, when your service desk ends tickets with them. A ticket for a device with a configuration item is linked to it. #### ConnectWise PSA 1. In ConnectWise PSA go to **System → Members → API Members** and add an API member with a security role that may read companies and configurations, add and change configurations, and add service tickets and notes. 2. On the API member, under **API Keys**, click **+** and copy the public and the private key (the private key is shown once). 3. In RackTrace fill in the **ConnectWise address** — the API address, such as `https://api-eu.myconnectwise.net` (`api-na` or `api-au` in other regions), or your own server — the **Company ID** you sign in with, the **Public key**, the **Private key** and the **ClientID**: ConnectWise asks every integration for one — register it (free, with a company e-mail address) at developer.connectwise.com under *ClientID*. Under **Defaults** choose the **Service board** where new tickets land (required), the source, the priorities and the **Configuration type** of new configurations. A configuration of a device is attached to the tickets made for that device. #### TOPdesk 1. In TOPdesk give the operator RackTrace signs in as (or an API account) a permission group with **API access → REST API** and **Use application tokens**, read and write rights for 1st and 2nd line incidents, and rights on the asset types RackTrace keeps. Make sure no branch filter hides your customers. 2. On the operator card, under **Application tokens**, click **Add** and copy the token — it is shown once. 3. In RackTrace fill in the **TOPdesk address** (`https://yourcompany.topdesk.net`), the **Login name** and the **Application token**. In TOPdesk your customers are **branches** (*vestigingen*). An incident gets the caller *RackTrace* at the branch of the tenant. Under **Defaults** choose the line, operator group, category, call type, entry type and processing status of new incidents, the **Asset type (template)** of new assets — its fields for serial number, MAC address and IP address are filled when it has them — and the **Reason for archiving** of an asset whose device was deleted. An asset is assigned to the branch and linked to the incidents made for its device. ### When a problem becomes a ticket RackTrace looks for problems in a tenant after every sync (discovery, Domotz) and when an alert is marked as seen: | Kind | What | Priority | |---|---|---| | Security alert (high) | An open [security alert](https://docs.racktrace.io/network/unifi-review#alerts) with severity high: a new port forward, a blocking firewall rule switched off, an open WiFi network … | High | | Security alert (medium) | An open security alert with severity medium | Medium | | Device offline | A linked device (switch, gateway, firewall, access point, server, UPS …) that every source reporting on it calls offline — not PCs, phones and printers | High for switches, gateways, routers and firewalls, otherwise medium | | Cabling check | What the [cabling check](https://docs.racktrace.io/integrations/discovery#cabling-check) reports as wired differently than documented (wrong port, mismatch), and a documented link between two network devices that is down | High for a link that is down, otherwise medium | For every kind choose **Automatically**, **With a button** or **Never** — under **Defaults** for the organization (by default only *Security alert (high)* is automatic), and per tenant with **Settings** in the list of tenants. - **Automatically**: a new problem gets a ticket by itself, within a minute after the sync that found it. A device must be offline for at least **Offline for at least (minutes)** (10 by default) first. - **With a button**: the problem is listed in the **Tickets** card with **Create ticket**. - **Never**: the problem is not listed. One problem makes **one** ticket, also when every sync sees it again. When RackTrace no longer sees it — the device is online again, the alert is marked as seen, the cabling is right — a note goes on the ticket (switch it off with **Add a note to the ticket when RackTrace no longer sees the problem**). RackTrace never closes a ticket. A problem that comes back while its ticket is still open gets a note on that ticket instead of a second one. > **Note** > > Problems that were already there when you linked a tenant (or made a kind automatic) never make a ticket by themselves — no flood of tickets for old news. They are listed with **Create ticket**. At most 20 tickets per tenant are made in one go; the rest follow a minute later. ### Tickets in RackTrace The **Tickets** card on the dashboard of a tenant, on a site page and on a device page (and **Tickets of this rack** in the rack inspector of the rack editor) shows: - **Problems RackTrace sees**: with the ticket that was made for it, *A ticket follows automatically*, or **Create ticket**; - **Made from RackTrace** (**Other tickets made from RackTrace** under problems): the other tickets made for this device, rack, site or tenant, with their state in the ticket system (brought up to date every 10 minutes, see **Update tickets and assets every (minutes)**); - **Open in …**: the open tickets in the ticket system of the client (dashboard and site) or of the device's asset (device page), also those made there. A rack shows only the tickets made from RackTrace. The number of a ticket opens it in the ticket system. **Create ticket** (on the card, or **Ticket** in the dialog of a port) opens a draft: the path and location of the device, the management IP and serial number, for a port the trace through patch panels and outlets, and a link back to RackTrace. Add what is wrong, choose the priority and click **Create ticket**. Creating tickets needs the right **Tickets** (see [Users and groups](https://docs.racktrace.io/administration/users-and-groups#roles)); editors have it, and every user who can see the tenant sees its tickets. ### Devices as assets Tick **Keep the devices of … as assets** in the **Settings** of a tenant. At the next sync (and then every 10 minutes for what changed) every device of the tenant becomes an asset or configuration item at its client: - name, serial number, MAC address, management IP, manufacturer and model, the location (site, room, rack and U) and a link back to RackTrace; - an asset that is already there is found by its **serial number** first (in HaloPSA, ConnectWise and TOPdesk also by **MAC address**) and kept up to date, so nothing is made twice; - patch panels, PATCHBOXes, outlets, blank panels, shelves and cable managers are left out; - a device that is deleted in RackTrace: its asset is set **inactive**, never deleted. A device with an asset shows the open tickets of that asset on its page, and new tickets for the device are linked to it. > **Caution** > > RackTrace is leading for these assets: a change made in the ticket system to a field RackTrace fills is overwritten at the next sync. --- ## Hudu and IT Glue > Connect Hudu or IT Glue — link every customer to its company, link devices to their assets or configurations, open them from RackTrace, and let RackTrace write a link back. URL: https://docs.racktrace.io/integrations/hudu-it-glue Hudu and IT Glue keep the documentation of your customers: passwords, procedures, contacts, licences. RackTrace is the **network layer next to it**: the racks, ports and cables, down to where every cable goes. Connect the two, and: - every tenant is linked to its **company** (Hudu) or **organization** (IT Glue); - its **assets** (Hudu) or **configurations** (IT Glue) are linked to the devices in RackTrace — suggested by **serial number**, then **MAC address**, then **name**, and confirmed by you; - a linked device has **Open in Hudu** or **Open in IT Glue** on its page and in the inspector of the rack editor; - optionally RackTrace writes a **link back** in Hudu or IT Glue: the address of the device in RackTrace, where it is in the rack and where its ports go. One platform per organization: Hudu or IT Glue. ### Connecting Hudu or IT Glue 1. Create an API key — see the steps per platform below. 2. In RackTrace, open **Administration → Integrations**, tab **Hudu / IT Glue**. Choose the **Platform** and fill in the details. 3. Click **Test connection**, then **Save**. 4. Under **Tenants**, choose for every tenant the company (Hudu) or organization (IT Glue) it is. When one has the same name, **Link to …** does it in one click. Its assets or configurations are read straight away. The API key is stored encrypted on the RackTrace server and never shown again or sent to browsers. **Remove API key** removes it. Choosing another **Platform** removes the links of the tenants and the devices; what RackTrace wrote in the old platform stays there. RackTrace reads the platform again every hour (**Read the platform again every (minutes)**, at least 15). With several app instances, one of them does this per organization, like the other background jobs. #### Hudu 1. In Hudu, go to **Admin → API Keys** and click **New API Key**. Leave **Password access** off: RackTrace never reads passwords. 2. In RackTrace fill in the **Hudu address** (`https://yourcompany.huducloud.com`, or the address of your own Hudu server) and the **API key**. RackTrace reads the companies that are not archived and their assets: the name, the asset layout, the serial number (the primary serial, else a field with *serial* in its name), the MAC address and IP address (the asset fields with those names) and the model. #### IT Glue 1. In IT Glue, go to **Account → Settings → API Keys**, under **Custom API Keys** click **+ Generate API Key**. Leave **Password Access** off. 2. In RackTrace choose the **Region** of your IT Glue account — **US** (`itglue.com`), **EU** (`eu.itglue.com`) or **Australia** (`au.itglue.com`) — and fill in the **API key**. RackTrace reads the organizations and their configurations that are not archived: the name, host name, type, serial number, MAC address, primary IP, manufacturer and model. > **The region** > > A key only works in the region of its account. *IT Glue refused the API key* with a key you just made usually means another region. ### Linking devices Open **Network → Hudu** (or **IT Glue**) — shown once the platform is connected. The page lists the assets or configurations of the tenant's company. - Filter with **All**, **Suggestions**, **Not linked**, **Linked** and **Ignored**; search on name, serial number, MAC address or model. - A **suggestion** is a RackTrace device with the same **serial number**, else the same **MAC address**, else the same **name** (or ID). It is only made when exactly one device fits, and one device is linked to one asset. Patch panels, outlets and other passive parts are never suggested. - **Accept** takes a suggestion; **Link all suggestions** takes them all. - The link icon links an asset to a device you choose; the unlink icon removes the link. - **Ignore** hides what has no device in RackTrace, such as laptops. - **Sync now** reads the company again. Linking needs the **Documentation** right on the tenant (see [Users and groups](https://docs.racktrace.io/administration/users-and-groups#roles)); everybody who can see the tenant sees the links. The history of the device records every link. ### Open in Hudu / IT Glue A linked device shows **Open in Hudu** or **Open in IT Glue**: - on the [device page](https://docs.racktrace.io/features/devices#device-page), at the top and as a line in **Details**; - in the [inspector of the rack editor](https://docs.racktrace.io/features/rack-editor#editor-inspector), under the name of the selected device. It opens the asset or configuration in a new tab. ### The link back to RackTrace Under **Link back to RackTrace**, tick **Write a link to RackTrace in …** and click **Save**. RackTrace then writes, for every linked device: - the address of its page in RackTrace; - where it is: site, room, rack and unit; - its ports with where their cable goes (through patch panels to the far end). Where it goes: | Platform | Place | |---|---| | Hudu | The asset field you choose under **Asset field for the link**. A *Website* or *Text* field gets the address, only when it is **empty or already holds the link of RackTrace**. A *RichText* field, such as *Notes*, gets a paragraph **after** what is in it. Tip: add a Website field *RackTrace* to the asset layouts of network devices and servers. | | IT Glue | The **notes** of the configuration: a paragraph after what is in them. | RackTrace never writes over text that is not its own: - A field that holds something else is left alone; the page of the tenant says *the field … is in use* in the column **Link back**. - When a device moves or is cabled differently, only RackTrace's own paragraph is replaced. - When a device is unlinked or deleted, the paragraph or link comes out again, and the field or notes are as they were before. - In Hudu, RackTrace sends the asset back with all its fields as it read them, and checks what Hudu answers. If any other field changed, RackTrace switches the link back off and says so under **Link back to RackTrace**. Look at what happened, then save with the link back switched on to start again. New and removed links get their link back within a minute; devices that moved are brought up to date when the platform is read again. Switching the link back off stops the updates: what was written stays until you switch it on again. Unlinking a tenant, or choosing another company or platform, leaves what was written in the old one — remove it there if you want. > **On your own server** > > RackTrace on your own server does not know the address your colleagues open it at. Fill in **Address of RackTrace (for the link)** (or set `RACKTRACE_PUBLIC_URL` on the server); without it, no link back is written. ### When something goes wrong | Message | What to do | |---|---| | *Hudu refused the API key* | Check the key under **Admin → API Keys** in Hudu, and that it is not expired or removed. | | *IT Glue refused the API key* | Check the key and the **Region**. IT Glue revokes keys that have not been used for 90 days. | | *… is busy (rate limit)* | IT Glue allows 3000 requests in 5 minutes. RackTrace tries again at the next run. | | *… is an internal address that RackTrace cannot reach* | On racktrace.io the Hudu address must be reachable from the internet. | | *the field … is in use* | The chosen field of that asset holds something else. Empty it in Hudu, or choose another field, then **Sync now**. | --- ## Two environments at one location > Keep two separate networks at one location apart in matching, imports and the network plan. URL: https://docs.racktrace.io/integrations/two-environments Some customers run two separate networks at one location, for example one for the office (IT) and one for production, each with its own UniFi or Domotz. RackTrace keeps them apart with [networks](https://docs.racktrace.io/concepts/networks). ### Setting it up Keep them apart like this: 1. Create the networks once under [Network plan → Networks](https://docs.racktrace.io/concepts/networks#networks), or with **+ New network…** in the network column. 2. Give each UniFi site, JSON scope and Domotz collector its **Network** in **Administration → Integrations**. Suggestions then only match devices of that network (and devices without one), so two switches with the same name and IP, one in each environment, are each matched with their own. Imported devices get the network, and the network plan keeps VLANs and profiles per network. Two environments under different UniFi accounts are two UniFi accounts in RackTrace. --- ## REST API and API tokens > Let scripts and other systems read and change your documentation through the RackTrace API, with an API token per system. URL: https://docs.racktrace.io/integrations/api Everything you see in RackTrace is also available through its REST API: the same addresses the app itself uses, under `/api` on your organization's address (e.g. `https://acme.racktrace.io/api/…`). A script, a PSA, a CMDB or a nightly export uses it with an **API token** instead of signing in. ### Making a token Only **administrators** make tokens (see [Roles and rights](https://docs.racktrace.io/administration/users-and-groups#roles)). 1. Go to **Administration → API tokens** and click **New token**. 2. Give it a **Name** that says who uses it, e.g. *CMDB sync* or *PSA*. Changes made with the token are in the history under this name. 3. Choose how long it is **Valid for**: 1 week to 1 year. After that it stops working by itself. 4. Choose what it **May** do: - **Read only** — look things up and export; it can never change anything. - **Read & write** — also add, change and delete. 5. Choose its **Tenants**: - **All tenants** — including tenants added later; - **Only the tenants ticked below**; - **The tenants and rights of a group** — the token gets exactly what a member of that [group](https://docs.racktrace.io/administration/users-and-groups#groups) gets; with *Read only* only what changes nothing. 6. Click **Create token** and copy it. It starts with `rta_` and is **shown only once**: RackTrace keeps only a fingerprint of it, so nobody — also not RackTrace — can show it again. Lost it? Withdraw it and make a new one. ![Administration → API tokens](https://docs.racktrace.io/assets/screens/api-tokens.webp "The API tokens of the organization: what each may do, its tenants, when it expires and when and from where it was last used.") > **One token per system** > > Make a separate token for every script or system. You then see what each one does, and you can withdraw one without stopping the others. ### Using a token Send the token with every request in the `Authorization` header. Requests that send data use JSON. What this token is and may do: ```bash curl -H "Authorization: Bearer rta_…" https://acme.racktrace.io/api/token ``` The tenants it can see, and the locations of one of them: ```bash curl -H "Authorization: Bearer rta_…" https://acme.racktrace.io/api/tenants curl -H "Authorization: Bearer rta_…" https://acme.racktrace.io/api/tenants/1/tree ``` All devices of a tenant as CSV: ```bash curl -H "Authorization: Bearer rta_…" -o devices.csv https://acme.racktrace.io/api/tenants/1/export/devices.csv ``` Add a site (read & write): ```bash curl -H "Authorization: Bearer rta_…" -H "Content-Type: application/json" \ -d '{"tenant_id": 1, "name": "Warehouse", "code": "WH"}' \ https://acme.racktrace.io/api/sites ``` Change a device (read & write): ```bash curl -X PUT -H "Authorization: Bearer rta_…" -H "Content-Type: application/json" \ -d '{"mgmt_ip": "10.0.10.21", "serial": "FDO2213X0AB"}' \ https://acme.racktrace.io/api/devices/42 ``` On your own server use your own address instead of `acme.racktrace.io`. The addresses, fields and answers are the same as those of the app: to see the request behind a screen, open the developer tools of your browser (`F12`, tab *Network*) and do it once in the app. ### What a token may do A token acts **as itself, never as the administrator who made it**, and RackTrace checks every request exactly as it checks a person: | Token | Acts like | Can | |---|---|---| | **Read & write** | An editor on its tenants (with a group: a member of that group) | Read, export, add, change and delete in its tenants — with a group only the parts the group's rights allow | | **Read only** | A viewer on its tenants | Read and export; every other request is refused (`token_read_only`) | A token is **never an administrator**: it cannot add or delete tenants, change global templates, or anything else that needs an administrator. Some parts are closed to **every** token, whatever its rights (`token_forbidden`): - signing in, accounts and *My account*; - users and groups; - **Login & security**, including Microsoft sign-in and support access; - API tokens themselves; - billing and the plan; - backups and system status; - the settings and keys of integrations; - share links — a public link would keep working after the token is withdrawn. A token whose group or tenants are deleted reaches nothing from then on — never more than before. ### Last use, history and limits - **Administration → API tokens** shows per token what it may do, its tenants, when it expires and when and from which address it was **last used**. - Everything a token changes is in the [history](https://docs.racktrace.io/features/history-and-search#history) as **API token** and its name, e.g. *API token PSA*. Making and withdrawing tokens are in the history too (filter on *API tokens*, scope *All tenants & system*). - At most **600 requests a minute** per token. Every answer says how many are left (`RateLimit-Remaining`); above the limit the answer is `429` with `Retry-After`: wait that many seconds. - Tokens are not part of backups: after a restore of the organization every token is gone and you make new ones. | Answer | Means | |---|---| | `401 token_invalid` | Unknown token: mistyped, or withdrawn | | `401 token_expired` | The token has expired — make a new one | | `403 token_read_only` | A change with a read-only token | | `403 token_forbidden` | A part no token may use | | `403` (other) | The token has no access to this tenant, or not this right | | `429 rate_limited` | Too many requests — wait `Retry-After` seconds | ### Withdrawing a token Click **Withdraw** next to the token in **Administration → API tokens**. It stops working at once: the next request with it gets `401`. An expired token stays in the list (marked *Expired*) until you **Remove** it. > **Caution** > > Treat a token like a password: keep it in the secret store of the system that uses it, never in a script you share or in a ticket. Suspect it leaked? Withdraw it. --- ## AI assistants > Let Claude, ChatGPT, Copilot or Cursor answer questions about RackTrace from these docs, through the MCP server, llms.txt or the Markdown version of every page. URL: https://docs.racktrace.io/integrations/ai-assistants AI assistants can answer questions about RackTrace from these docs: how to patch a cable in the rack editor, what a trunk is, how to link UniFi. They read the same pages you do, in English or Dutch. They only get the documentation: your sites, racks and cables in RackTrace stay where they are. There are two ways. Connect your AI tool to the **MCP server** of the docs, so it searches and reads them by itself, or give it **llms.txt** or a page as Markdown. ### Connect your AI tool (MCP) The docs have an MCP server (Model Context Protocol) at this address: ```text https://docs.racktrace.io/mcp ``` Add it to your AI tool as a remote MCP server. It needs no account, key or sign-in, and it can only read the docs. Then ask your questions as usual: the assistant searches the docs when it needs them and tells you which pages it used. #### Claude 1. In Claude (the website or the desktop app), go to **Customize › Connectors**, click **+ Add** and choose **Add custom connector**. 2. Name it `RackTrace docs` and paste `https://docs.racktrace.io/mcp` as the address. 3. Choose **No sign in** and click **Add**. 4. In a chat, switch the connector on under **+ › Connectors** when you need it. On a Team or Enterprise plan, an owner adds the connector once under **Organization settings › Connectors**. Everyone in the organisation can then switch it on. #### Claude Code ```bash claude mcp add --transport http racktrace-docs https://docs.racktrace.io/mcp ``` Add `--scope user` to use it in all your projects. #### Cursor Add the server to `.cursor/mcp.json` in your project, or to `~/.cursor/mcp.json` for all projects, and restart Cursor: ```json { "mcpServers": { "racktrace-docs": { "url": "https://docs.racktrace.io/mcp" } } } ``` #### VS Code with GitHub Copilot Run **MCP: Add Server** from the command palette, choose **HTTP** and paste the address. Or add it to `.vscode/mcp.json`: ```json { "servers": { "racktrace-docs": { "type": "http", "url": "https://docs.racktrace.io/mcp" } } } ``` Copilot Chat uses it in agent mode. #### ChatGPT Switch on **Developer mode** in the settings of ChatGPT (under **Connectors** or **Apps**, **Advanced settings**), create a connector with the address and choose **No authentication**. Developer mode depends on your plan, and the names of the menus change now and then. #### Other tools Any tool that supports remote MCP servers over HTTP (*Streamable HTTP*) can use the address. The server speaks the current revision of MCP (2026-07-28) as well as the revisions of 2025, so newer and older tools both work. #### What the assistant can do | Tool | What it does | |---|---| | `search_docs` | Searches the docs like the search at the top of this page, and returns the best pages and sections with their address. In English (`en`) or Dutch (`nl`). | | `get_page` | Reads one page in full. | | `list_pages` | Lists all pages, per section. | ### Without MCP: llms.txt and Markdown AI tools that cannot use MCP can still read the docs as plain text: | Address | What it is | |---|---| | [/llms.txt](https://docs.racktrace.io/llms.txt) | The list of all pages with a short description, in the format for AI tools of [llmstxt.org](https://llmstxt.org). In Dutch: [/nl/llms.txt](https://docs.racktrace.io/nl/llms.txt). | | [/llms-full.txt](https://docs.racktrace.io/llms-full.txt) | All pages in one file. Add it to a chat or a project, and ask away. In Dutch: [/nl/llms-full.txt](https://docs.racktrace.io/nl/llms-full.txt). | | A page with `.md` | Every page as Markdown: add `.md` to its address, for example [/features/rack-editor.md](https://docs.racktrace.io/features/rack-editor.md). | ### Good to know > **Only the documentation** > > The MCP server, llms.txt and the Markdown pages contain these public docs and nothing else. An assistant cannot see or change anything in your RackTrace organisation through them. - Ask in your own language: the assistant can search both the English and the Dutch docs. - An answer from an AI can be wrong. Check the page it links to before you change something in your network. --- ## Setting up a new organisation > Create the first administrator from the invitation link and take the first steps. URL: https://docs.racktrace.io/administration/setting-up Start a free trial on the website with [Start free trial](https://racktrace.io/demo): fill in your name, company, work e-mail address and the address you want (such as `yourcompany.racktrace.io`). RackTrace sets up your organisation straight away, checks that it is live and e-mails you an invitation link — usually within a minute. When RackTrace sets up an organisation for you another way, you receive the same kind of link. With it you create the first administrator, who can then invite everyone else. ### The first administrator 1. Open the invitation link. The page **Welcome to RackTrace** asks for the first administrator account. 2. Fill in **Your name**, **E-mail address (you sign in with it)**, **Password (min. 8 characters)** and, optionally, **First tenant / organisation** (for example your company or your first customer). After a trial started on the website, your name and e-mail address are already filled in. 3. Leave **Also load a demo tenant with sample racks and cabling** ticked to get a fully cabled example to explore. You can delete it later. 4. Click **Create administrator**. You are signed in and land on the dashboard. Next steps: add your colleagues under [Users](https://docs.racktrace.io/administration/users-and-groups#users), create a tenant per customer under [Tenants](https://docs.racktrace.io/administration/tenants#tenants), and start documenting with [your first site](https://docs.racktrace.io/features/locations#create-locations). --- ## Tenants > Create, rename and delete tenants, and load a demo tenant. URL: https://docs.racktrace.io/administration/tenants A tenant is a fully separated environment: your own organisation, or one of your customers. Everything you document belongs to a tenant, and people only see the tenants they have access to. ### Managing tenants Open **Administration → Tenants**. - **New tenant**: give a **Name** (unique) and **Notes**, then click **Create tenant**. - **Load demo tenant** creates *Demo Company*, a fully cabled example to explore or practise on. - Edit renames a tenant. Delete removes it with everything in it: type the tenant's name to confirm. Download a [full backup](https://docs.racktrace.io/features/export#export) first. - Importing a tenant from a JSON backup is done on [Export & reports](https://docs.racktrace.io/features/export#export). --- ## Users, groups and rights > Roles, the rights of groups, adding users and giving a team access to tenants. URL: https://docs.racktrace.io/administration/users-and-groups What someone may do in RackTrace is the sum of their role and the groups they are in. ### Roles and rights | Role | Can do | |---|---| | Viewer | Read, export and print in the tenants ticked on the user. | | Editor | All rights in the tenants ticked on the user, except Credentials. | | Administrator | Everything in all tenants, plus users, groups, login & security, [API tokens](https://docs.racktrace.io/integrations/api), integrations, tenants, global templates and import. | **Groups** add access on top of the role. Being in a group always gives read access to its tenants; the group's rights decide what members may change: | Right | Covers | |---|---| | Documentation | Sites, floors, rooms, racks, devices and ports, and their links to [Hudu or IT Glue](https://docs.racktrace.io/integrations/hudu-it-glue) | | Cabling | Cables, trunks and connections | | Network plan | VLANs, port profiles, networks, routes, WAN / VPN, WiFi, firewall, port forwards and reservations | | Domotz | Sync, link, import and ignore Domotz devices | | Device templates | Templates of the tenant in the device library | | Credentials | Set, change and delete the credentials the scanner logs in to devices with (see [Network monitoring](https://docs.racktrace.io/network/monitoring#credentials)); nobody sees their values. Not part of the editor role: give it through a group | | Export | CSV and JSON exports, the printable report and — for editors and administrators, never viewers — [share links](https://docs.racktrace.io/features/share-links) | | Tickets | Create tickets in the ticket system (see [Ticket systems](https://docs.racktrace.io/integrations/ticket-systems)) | A user can do the sum of their role on the tenants ticked directly and the rights of all their groups. The server checks every change, and the screens hide what you cannot do. Scripts and other systems do not need an account: give them an [API token](https://docs.racktrace.io/integrations/api) — read only or read & write, on all tenants, some tenants or those of a group. ### Users 1. Open **Administration → Users** and click **New user**. 2. Fill in the **E-mail address** (the user signs in with it) and **Display name**. 3. Choose the **Role**: **Administrator**, **Editor** or **Viewer**. 4. Under **Account**, leave **Send an invitation by e-mail** chosen. Or choose **Set a password myself**, fill in a **Password** and leave **User must choose a new password at the next sign-in** ticked. 5. Tick the **Groups** and/or the **Tenants** the user gets directly. 6. Click **Save**. With an invitation the user gets an e-mail that explains what RackTrace is, their role and access, how to create their account and what is expected of them; replies to it reach you. With the link in it (it works once, for 7 days) they choose their own password, or sign in with Microsoft, and set up two-step verification when you require it. See [Creating your account from an invitation](https://docs.racktrace.io/signing-in#invitation). - Until then the user is **invited** in the list. **Send the invitation again** (the envelope) sends a new link, also when the first one expired (**invitation expired**); the link sent before stops working. - Setting a password with Edit ends the invitation: give them the password yourself. A new e-mail address sends the invitation to that address. - After their first sign-in every new user gets a second e-mail: how RackTrace works, in two minutes, with links to these docs. With a password you give it to the user yourself; they sign in with their e-mail address. On RackTrace on your own server, without e-mail, that is the only way. ![The Users page](https://docs.racktrace.io/assets/screens/users.webp "Administration → Users: accounts, roles, access and two-step verification.") Per user: - Edit changes the e-mail address they sign in with (at once: an address you enter counts as checked), the role, groups and tenants, or sets a new password (this signs the user out everywhere). Untick **Account active** to block someone without deleting them. - An **old username** badge means the account still has a username from before. The user is asked for their e-mail address at the next sign-in, or you enter it with Edit. An address a user entered themselves and has not confirmed yet is shown under their name, with *to confirm*. - The eye icon shows the effective access per tenant. - **Reset two-step verification** removes the app, the passkeys and the recovery codes when someone lost their phone or device; they set it up again at the next sign-in. - **Sign out everywhere** ends all their sessions. - Delete removes the user; their history stays. - The RackTrace support account is not in the list. You find it under [Support access](https://docs.racktrace.io/administration/login-and-security#support-access). - Users linked to a Microsoft account carry a **Microsoft** badge. **Unlink from the Microsoft account** ends their Microsoft sessions; the next Microsoft sign-in with that e-mail address links the account again. Use it when the address now belongs to someone else. With [Sign in with Microsoft](https://docs.racktrace.io/administration/microsoft-sign-in#microsoft-sign-in), the e-mail address must be the person's Microsoft sign-in name, usually their work e-mail address (e.g. `jan@company.com`). There must always be at least one active administrator. ### Groups Groups give a team access to tenants, with rights per part. Examples: *Engineers* (all tenants, all rights), *Servicedesk* (all tenants, read + export), *Customer St. Paul* (only that tenant, read only). ![The Groups page](https://docs.racktrace.io/assets/screens/groups.webp "Administration → Groups: teams with access to tenants and rights per part.") 1. Open **Administration → Groups** and click **New group**. 2. Fill in a **Name** and **Description**. 3. Tick the **Rights**. Without any right ticked, the group gives read-only access. 4. Tick **All tenants — including tenants added later**, or choose the **Tenants**. 5. Tick the **Members** (administrators don't need groups) and click **Save**. --- ## Login & security > The look of the login page, the two-step verification policy, and support access. URL: https://docs.racktrace.io/administration/login-and-security Under **Administration → Login & security** you set what your people see when they sign in and how they sign in. ### Login page and two-step policy Open **Administration → Login & security**. ![The Login & security page with the branding and a preview](https://docs.racktrace.io/assets/screens/login-security.webp "Login & security: the look of the login page, with a live preview, and the two-step policy.") #### Login page & branding Set the **Name** (shown on the login page, in the top bar, the browser tab and the authenticator app), a **Tagline**, a **Welcome text on the login page** (for example who to contact for an account), a **Logo** (PNG, JPG, WebP or SVG, max. about 290 KB) and an **Own colour** for the login page. The **Preview** shows the result. Click **Save**. #### Two-step verification policy - **Optional**: users turn it on themselves under My account. - **Required for administrators**: administrators set it up at their next sign-in. - **Required for everyone**: every user sets it up at their next sign-in. A passkey or the authenticator app both meet the policy. If you require it but don't have it yourself, you are asked to set it up straight after saving. People who sign in with [Microsoft](https://docs.racktrace.io/administration/microsoft-sign-in#microsoft-sign-in) get their second step from Microsoft instead. ### Support access by RackTrace On racktrace.io, **Allow RackTrace support to sign in** (under **Administration → Login & security**) lets the RackTrace team help you in your organisation as the account *RackTrace support*. - The support team needs two-step verification to sign in. - A support session ends after at most 4 hours, and shows *RackTrace support · name* in the top bar. - Every change is in the history as *RackTrace support (name)*. - Switching it off also ends an open support session. The card shows the last support sign-in. - The support account is not one of your users: it is not in the list under **Users** and does not count for your plan. While a support session is open, the card says so, with **End it**. --- ## Sign in with Microsoft > Let your people sign in with their Microsoft 365 work account (Microsoft Entra ID). URL: https://docs.racktrace.io/administration/microsoft-sign-in With Microsoft sign-in, your people use their work account and Microsoft checks the password and the second step. ### Setting it up Your people sign in with their work account (Microsoft Entra ID, the accounts of Microsoft 365). Microsoft checks the password and the second step (MFA, Conditional Access); whoever leaves your organisation in Microsoft has no more access here. Set it up in the card **Sign in with Microsoft** under **Administration → Login & security**. 1. In the Microsoft Entra admin center, go to **App registrations** → **New registration**. Name it (e.g. RackTrace), choose *Accounts in this organizational directory only*, and add a redirect URI of type **Web** with the **Redirect URI (Web)** shown in the card in RackTrace (**Copy** copies it). 2. From the **Overview**, copy the **Application (client) ID** and the **Directory (tenant) ID** into the card. 3. Under **Certificates & secrets**, create a new client secret and paste its **Value** (not the Secret ID) in **Client secret**. Note when it expires and enter a new one before then. 4. Tick **Show “Sign in with Microsoft” on the login page**. Optionally tick **Required — only administrators can sign in without Microsoft** and **Create an account at the first Microsoft sign-in** (with the **Role of new accounts**: viewer or editor; they get no tenants until you grant them). 5. Click **Save**. An account is found by its Microsoft sign-in name (UPN, usually the work e-mail address), which must be the e-mail address it signs in with here. Optionally, in Entra under *Enterprise applications → RackTrace → Properties*, set *Assignment required* to Yes and assign the people or groups who may use RackTrace. When Microsoft reports a problem, such as an expired secret or a wrong redirect URI, the card shows it as **Last problem**. > **Note** > > With **Required** on, administrators keep their password (with two-step verification) as the way in when Microsoft is not available. Open password sessions of other users end when you save, and so do those of an administrator you later make an editor or viewer. Switching Microsoft sign-in off, or changing the directory or application ID, ends every session that was started with Microsoft. --- ## System status and monitoring > Check that everything works, see the subscription, and monitor RackTrace from Zabbix. URL: https://docs.racktrace.io/administration/system-status Administrators can see at a glance whether everything in RackTrace works, follow the backups, and let Zabbix keep an eye on it. ### System status **Administration → System status** shows whether everything works: ![The System status page](https://docs.racktrace.io/assets/screens/system-status.webp "System status: the checks, the backups and the system information.") - **Checks**: the database, Domotz, every UniFi or JSON source (failing or stale syncs), backups, encryption of secrets and server errors, each **OK**, **Warning** or **Problem**. While a check fails, administrators see a warning bar on every page. - **Backups**: the schedule, the last backup and its check, and the off-site copy. **Back up now** makes one straight away. A backup is made every night. - **Subscription** (racktrace.io): your plan, the trial end and your usage of racks, users, tenants and devices against the plan. - **System** information and the **Recent server errors**. Want a copy of every backup in your own storage as well? See [Backups in your own storage](https://docs.racktrace.io/administration/backups#own-backups). ### Monitoring with Zabbix 1. On **System status**, in **Monitoring with Zabbix**, click **Create token** and copy it; it is shown once. 2. Click **Zabbix template (YAML)** and import the file in Zabbix 6.0+ under *Data collection → Templates → Import*. 3. Create a host, link the template *RackTrace by HTTP* and set the macros `{$RACKTRACE.URL}` (your RackTrace address) and `{$RACKTRACE.TOKEN}`. Zabbix then warns when RackTrace is down, reports a problem or a warning, has many server errors, restarted or was updated. **Revoke** removes the token. --- ## Billing — plan, payment and invoices > Choose or change your RackTrace plan, save a payment method, see and pay your invoices, and keep your billing details up to date. URL: https://docs.racktrace.io/administration/billing On racktrace.io, administrators find the subscription of the organization under **Administration → Billing**: the plan, how invoices are paid, the billing details and every invoice. ### Choosing a plan During the trial, **Choose a plan** starts the subscription: 1. Choose the **plan** and whether it is invoiced **every month** or **every year** (12 months at once). Prices are without VAT. 2. Fill in the **billing details**: company name, address, country, and your VAT number if you have one. A VAT number of an EU country is checked with VIES, the EU's check of VAT numbers; one VIES does not know is refused. A business elsewhere in the EU with a VAT number is invoiced with VAT reverse-charged; without one the invoice carries VAT — possibly at the rate of your own country (the EU One-Stop Shop). **Invoices go to** is the e-mail address that receives the invoices; **Language** chooses English or Dutch invoices and e-mails. 3. Accept the **terms of service** and the **data processing agreement** on behalf of the organization (each has a link to read it). 4. Click **Start subscription**. RackTrace continues straight away — everything stays as it is — and the invoice for the first period follows by e-mail, with a button to pay it online. Did the trial already end? Then nobody can sign in. Use **Choose a plan** in the e-mail that said the trial ended: it opens the same choice on a page of its own (the link is valid for 30 days). No e-mail? Ask RackTrace for a new link. ### Changing the plan **Change plan** chooses another plan: - A **larger plan** applies straight away. You pay the difference over the days that are left in the current period: on an invoice of its own when that period was invoiced already, otherwise on the invoice for that period. - A **smaller plan** applies from the next period, its limits too. Until then **Plan** shows which plan comes next and from which day. Racks above the ones included in the plan are counted when each invoice is made. ### Usage and limits **Usage** shows what the organization uses of each limit of its plan, such as *12 of 100 monitored devices* and *2 of 3 scanners*, in all tenants together. From 80% it turns orange. Every scanner counts, switched on or not: delete one to make room. Above a limit nothing is removed: a new rack, user, tenant or scanner is refused, and a device above the monitored devices is documented but not monitored ([Monitoring](https://docs.racktrace.io/network/monitoring#monitored-devices)). ### Paying Invoices can be paid in three ways: - **Automatically**: **Save a payment method** opens a secure page of Stripe, where you save a card or a SEPA Direct Debit mandate. From then on every invoice is collected when it is made — the invoice e-mail says so. - **Online**: the button in the invoice e-mail, or **Pay online** in the list of invoices, pays with a card, iDEAL or Bancontact. The link in the e-mail keeps working; the payment page of Stripe it opens is valid for an hour — after that, click the button again. - **Bank transfer**: to the account on the invoice, stating the invoice number. When a payment does not go through — a card that was declined, or a bank that asks you to confirm — you receive an e-mail with a link to pay online. Paid an invoice twice through Stripe (for example online after it was collected automatically)? The second payment is refunded automatically. Paid by bank transfer and online as well? Then RackTrace sees it and contacts you about the refund. ### Invoices and billing details **Invoices** lists every invoice and credit note with its status. **PDF** opens it; **Pay online** is there while it is open. Change the company name, address, VAT number or the address that receives the invoices under **Billing details → Edit**; a new invoice uses them, one that was sent already stays as it was (a mistake is corrected with a credit note). **Agreements** shows which version of the terms of service and of the data processing agreement was accepted, by whom and when. Only administrators see **Billing**. When RackTrace support is signed in for you, they can look and correct the billing details, but never choose a plan or save a payment method in your name. --- ## Backups > Nightly backups, making a backup now, a copy in your own storage, and a full backup of one tenant. URL: https://docs.racktrace.io/administration/backups RackTrace makes a backup of your organisation every night. You can also keep your own copy. ### Nightly backups Every night RackTrace makes a complete backup of your organisation, checks it, and keeps a copy outside the data centre. Every copy is encrypted, with a key that belongs to your organisation only. The **Backups** card on [System status](https://docs.racktrace.io/administration/system-status#system-status) shows the schedule, the last backup and its check, and the off-site copy. - **Back up now** makes a backup straight away, for example before a big change. - When the last backup is more than a day old, or the off-site copy failed, the **Backups** check turns orange or red, and administrators see a warning bar. - To get data back, contact RackTrace support: a backup of one organisation can be restored without touching any other. ### A full backup of one tenant **Export & reports → Full backup (JSON)** downloads everything in one tenant. An administrator can import that file again as a new tenant. See [Export and reports](https://docs.racktrace.io/features/export#export). ### Backups in your own storage Every night's backup can also go to a bucket of your own, on any S3-compatible storage (AWS S3, Backblaze B2, Wasabi, MinIO, Hetzner, Cloudflare R2 …). It is the complete snapshot of your organisation as gzipped JSON, encrypted in the standard [age](https://age-encryption.org) format: yours to keep and read. 1. Open **Administration → System status** and, in the card **Copy to your own storage**, open **Set up a copy to your own storage**. 2. Fill in the **Endpoint**, **Bucket**, **Region** and **Folder**, and the **Access key** and **Secret key**. Tick **Path-style addresses** for most storage that isn't AWS. 3. Set **Copies to keep** (0 = all; the bucket's own rules decide). 4. Choose how the copies are encrypted (see below): **a passphrase** (twice) or **my own key**. 5. Tick **Copy every backup there**, click **Test** and then **Save**. The card shows the last copy, or why it failed; a failure also shows as a warning in the backup status. Give RackTrace a key that can only write to that bucket (and list and delete in the folder, to remove old copies). #### Encryption: your own key or a passphrase The copies are always encrypted. You choose with what: - **My own key** (recommended): only whoever has the secret key can read the copies — RackTrace cannot, because it only gets the public key (`age1…`). Click **Make a key pair**: your browser makes the key, saves the secret key as `racktrace-backup-key.txt` on your computer and fills in the public key. Keep that file safe (a password manager, a safe, two copies): without it nobody can read the copies, RackTrace support included. You can also make the key yourself with `age-keygen -o key.txt` and paste its public key. Several public keys (one per line) let several people each read the copies with their own key. - **A passphrase** of at least 12 characters. RackTrace keeps it encrypted, because it needs it for every copy. RackTrace cannot tell it to you, so keep it in your password manager. To read a copy, use the standard **age** tool (for Windows, macOS and Linux, see [age-encryption.org](https://age-encryption.org)): ```bash age -d -i racktrace-backup-key.txt -o racktrace-….json.gz racktrace-….json.gz.age ``` Without `-i`, `age -d` asks for the passphrase. Or download **decrypt-backup.mjs** from the card (Node.js 18 or newer, nothing to install): `node decrypt-backup.mjs -i racktrace-backup-key.txt racktrace-….json.gz.age`, or without `-i` for a passphrase. Both write the `.json.gz`. Did you set a passphrase before this was introduced? Then your copies are still in an older format (`.json.gz.rtbk`), which `decrypt-backup.mjs` reads. Enter your passphrase again, or choose your own key, to switch to age. --- ## Your account > Your name and access, your password, passkeys, the authenticator app, recovery codes and sessions. URL: https://docs.racktrace.io/account/my-account Open the user menu (your name at the top right) and choose **My account** for your name, password, passkeys, authenticator app, recovery codes and sessions. ### Profile and access - **Profile** shows your e-mail address, role and groups. Change your **Display name** and click **Save**. - To sign in with another e-mail address, click **Change** next to it, enter the new address and your password, and click **Change**. RackTrace e-mails a link to the new address: your address changes once you open it and click **Confirm e-mail address** — until then you keep signing in with the current one. Meanwhile the profile shows the new address with **Send again** and **Cancel**. The link works once and for 24 hours. - **Access** lists every tenant you can open and your rights in it (for example Documentation, Cabling, or *read only*). ![The My account page](https://docs.racktrace.io/assets/screens/account.webp "My account: profile, access, password, two-step verification and sessions.") Signed in with Microsoft? Then your password and second step are managed by Microsoft; change them with your organisation's IT. If you also have a RackTrace password, the password and two-step settings on this page are for signing in without Microsoft. ### Changing your password 1. On **My account**, in the **Password** card, fill in your **Current password**, the **New password** and **Repeat new password**. Use at least 8 characters; a short sentence is easier to remember and harder to guess. 2. Click **Change password**. Your other sessions are signed out. **Change password** in the user menu does the same in a quick dialog. ### Passkeys A passkey signs you in with your fingerprint, face or device PIN, with no password. It can be saved on your computer (Windows Hello, Touch ID), your phone, a password manager (iCloud Keychain, Google Password Manager, 1Password, Bitwarden …) or a security key. It also counts as two-step verification. 1. On **My account**, under **Two-step verification**, click **Add passkey**. 2. Fill in **Confirm with your password** and optionally a **Name** (e.g. Work laptop, iPhone). 3. Click **Create passkey** and follow your browser. 4. If this is your first second step, save the [recovery codes](https://docs.racktrace.io/account/my-account#auth-app) that appear. The list shows each passkey with whether it is synced or on this device only, and when it was last used. The pencil renames it; the bin removes it after you enter your password. If your administrator requires two-step verification, you can't remove your last passkey until you have another one, or the app. > **Note** > > Passkeys need the app opened by its domain name over HTTPS, not an IP address, in a recent browser. A passkey made on one address only works on that address. ### Authenticator app and recovery codes 1. Next to **Authenticator app**, click **Set up**, fill in **Confirm with your password** and click **Next**. 2. Scan the QR code with Microsoft Authenticator, Google Authenticator, 1Password, Bitwarden or a similar app. Can't scan? Open **Can't scan? Enter the key by hand** and copy the key. 3. Enter the 6-digit code the app shows. If it's refused, check that the time on your phone is correct. 4. Save the 10 recovery codes with **Copy** or **Download**, tick **I have saved these recovery codes** and click **Continue**. Each recovery code works once, for when you have neither your passkey nor your phone. The codes are shown only once; **New codes** makes a new set and stops the old ones. When three or fewer are left, RackTrace reminds you. **Turn off** removes the app after you enter your password. ### Sessions and signing out **Signed-in sessions** lists every browser where you are signed in, with device, IP address, when you signed in and when it was last active. **Sign out other sessions** ends all except this one. **Sign out** in the user menu ends the current one. ### Dark mode, help and the version - **Toggle dark mode** in the user menu switches between light and dark; your browser remembers the choice. - **Help & docs** opens these docs in a new tab. - The RackTrace version is shown in the user menu and at the bottom of the side menu; mention it when you report a problem. --- ## Troubleshooting > The messages you are most likely to meet, and what to do about them. URL: https://docs.racktrace.io/troubleshooting The messages you are most likely to meet, and what to do about them. Can’t find yours? [Let us know](mailto:info@racktrace.io). ### Messages in the rack editor | Message | What to do | |---|---| | U5 is occupied by SW01 (U5–U6) | Choose another U, or move SW01 first. The U you drop on becomes the top of the device. | | Does not fit: U41–U43 is outside this 42U rack | Drop the device lower, or make the rack higher in its settings. | | No free 2U space left in rack RK001 | Make room, or put the device in another rack. | | Cannot shrink rack to 24U: a device occupies U30 | Move the device down first. | | SW01/5 is already connected | Each port has one cable. Disconnect it first, or drag the connected port to move its cable. | | These ports are the front and rear of the same pass-through port | Connect a cable to a port of another device. | | ID may only contain letters, digits and . _ - + # | Remove spaces and slashes from the ID. | | ID "SW01" is already used in this rack | IDs are unique within the rack or room; choose another one, or leave it empty. | No **+** on a U? The **+** and click-to-place only work on completely empty units. To put a device in front of a half-depth device mounted at the back, drag it from the panel. ### “You are not allowed to …” Messages such as *You are not allowed to change the documentation of this tenant*, or a button that is missing, mean your role or groups don't include that right. The **Access** card on [My account](https://docs.racktrace.io/account/my-account#my-account) shows what you have. Ask an administrator to add the right to one of your [groups](https://docs.racktrace.io/administration/users-and-groups#groups). Rack editor showing **Read-only**? You can look, but not change. ### Can't sign in - **Invalid e-mail address or password**: check both. Still have a username from before? Sign in with that once on your organisation's address ([an account with a username from before](https://docs.racktrace.io/signing-in#old-username)). Forgotten password? Ask an administrator for a temporary one. - **The sign-in took too long or was finished in another browser**: sign in again on `app.racktrace.io` and finish within 5 minutes, in the same browser. - **… signs in with Microsoft** on `app.racktrace.io`: your organisation requires Microsoft sign-in. Follow the link to its address and click **Sign in with Microsoft**. - **This link no longer works** after *Confirm your e-mail address*: the link was used, a newer one was sent, or 24 hours have passed. Sign in and ask for a new one. - **Too many failed attempts. Try again in 15 minutes.** After 10 wrong passwords or codes from one address within 15 minutes the account is locked from that address for the rest of the 15 minutes; after 50 sign-in attempts for one account within 15 minutes, from any address, it is locked everywhere for the rest of that time. Wait until the time is up, then try again carefully. - **That code is not valid**: check the time on your phone, wait for the next code, or use a recovery code. - **Lost your phone or passkey** and have no recovery codes left? An administrator can reset your two-step verification under [Users](https://docs.racktrace.io/administration/users-and-groups#users). - **There is no account here for your Microsoft account yet**: ask an administrator to add you, with your Microsoft sign-in name (usually your work e-mail address) as e-mail address. - **That Microsoft account belongs to another organization**: sign in with your work account. - **Sign in with Microsoft is not set up correctly**: an administrator can see why in the card [Sign in with Microsoft](https://docs.racktrace.io/administration/microsoft-sign-in#microsoft-sign-in). - **No organization with that address**: check the spelling, or ask your administrator for the link. - **Trial ended** or **Organization suspended**: your data is kept. Contact your administrator or RackTrace. ### Passkey not offered or not working - Open RackTrace by its domain name over HTTPS. On an IP address, passkeys are not offered. - **This passkey is not known here**: sign in with your password and add the passkey under My account. A passkey made on another address only works there. - **No passkey was used (cancelled or timed out)**: try again and finish the browser's prompt. ### Other questions - **“Your plan allows … racks and you have …”** (or scanners, or monitored devices) Your subscription is full. The **Usage** card under [Administration → Billing](https://docs.racktrace.io/administration/billing#usage) shows your usage; ask RackTrace for a larger plan. - **A model isn't in the device library.** Duplicate a similar template and adjust it, or make a [new template](https://docs.racktrace.io/features/device-library#templates). - **Search doesn't find a path or MAC address.** Search for one ID at a time; MAC addresses can be found on the [Discovery](https://docs.racktrace.io/integrations/discovery#discovery) page and the [IP addresses](https://docs.racktrace.io/network/ip-addresses#ipam) tab. - **The floor plan shows no lengths.** Set the scale with the ruler ([Setting the scale](https://docs.racktrace.io/features/floor-plans#plan-scale)). - **Discovery shows nothing.** An administrator first links the UniFi site (or JSON scope) to the tenant and location under [Integrations](https://docs.racktrace.io/integrations/unifi#unifi-setup). - **A colleague's change doesn't appear.** It waits while you are typing, dragging or have a dialog open; click **Update now** in the bar. - **Labels print too small or shifted.** Print at 100 % with margins **None**, and use **Printer adjustments** (see [Printing labels](https://docs.racktrace.io/features/labels#labels-print)).