# Onboarding a tenant

> The steps that make a new tenant usable, worked out from the data, and a list of what is still missing — each line with a button to where you solve it.

URL: https://docs.racktrace.io/network/onboarding

**Onboarding** shows what a new tenant still needs before it is usable: the steps, how far each one is, and a list of what is missing. RackTrace works it all out from the documentation and from what discovery sees — there is nothing to tick off. Open it from the menu (**Network → Onboarding**) or from the card on the dashboard.

## The steps

| Step | Required | Done when |
|---|---|---|
| **Location** | yes | The tenant has a site with a room. |
| **Discovery source** | yes | A UniFi site, Meraki network, FortiGate, scanner or JSON source is linked to the tenant. |
| **First discovery** | yes | The source synced and saw network devices. |
| **Core devices linked** | yes | Every switch, router, gateway, firewall and access point discovery sees is linked to a documented device. |
| **Uplinks cabled** | yes | Every uplink port of a linked device has a documented cable. |
| **VLANs documented** | yes | Every VLAN in the network configuration a source reports is in the network plan. |
| **Racks** | no | Every documented switch, router, gateway and firewall is in a rack. |
| **Monitoring and notifications** | no | Monitoring is on, something is monitored, and a notification policy that is switched on mails when an alert opens. |

A step can also say **Cannot be checked**: the sources do not report what it needs — no uplinks, or no network configuration. That is not the same as missing; it does not hold the tenant back.

When every required step is done, the page becomes **Documentation health**: the same overview, for when the network changes later.

## Core devices linked

The bar at the top shows which part of the core devices is linked, with the goal of **80%** marked on it. Core devices are the switches, routers, gateways, firewalls and access points discovery sees.

- A device reported by two sources (the same MAC address, or linked to the same documented device) counts once.
- A device you **ignore** under Discovery, or that the source no longer reports, does not count.
- Servers, NAS devices and other infrastructure do not count.

## What is missing

Per kind, with a button on every line:

- **Core devices not linked** — **Link** opens [Discovery](https://docs.racktrace.io/integrations/discovery#devices) on the devices that are not linked.
- **Uplinks without a documented cable** — with the neighbour discovery sees on the other end (LLDP). **Connect cable** opens the device. A cable that is only planned does not count: it is not there yet.
- **VLANs seen but not documented** — the networks a source configures that are not in the network plan: the same list as the [review in the network plan](https://docs.racktrace.io/network/unifi-review), where **Review** takes you to take them over. A VLAN that is only seen on a port (the native VLAN 1 that most switches report on every port, for example) does not count.
- **VLANs documented but not seen** — in the plan, but no source configures them: perhaps they are no longer in use. The review proposes to remove them; they do not hold the step back.
- **Network devices without a rack** — access points are left out: they hang on a wall or a ceiling.

A list shows at most 100 lines, with the total next to its title.

## Discovery sources

Per linked source the last sync, how many network devices and clients it sees, and how fresh its last report is, with the label of the device page: **Observed … ago** while fresh, **old** once it is older than the threshold of its kind of source (6 hours, see [Source and freshness](https://docs.racktrace.io/concepts/source-and-freshness#thresholds)) — what it says may no longer be true — and **Not observed yet** when it never reported. This used to be 24 hours on this page; it is now the same threshold everywhere. **sync failed** shows the error of the last sync.

## Who sees what

Everyone with access to the tenant sees its onboarding. The buttons open the pages where the work is done, and those pages ask for the usual rights: linking a source is for administrators, linking devices and cabling need the right to change the documentation, VLANs the right to change the network plan, notification policies the right to change monitoring.