# Quickstart

> Your first rack in ten steps, from an empty tenant to a cable traced from the PC to the switch.

URL: https://docs.racktrace.io/quickstart

This guide takes you from an empty tenant to a complete, traced cable: a switch and a patch panel in a rack, a floor box in an office, and a PC plugged in. Do the steps in order; each takes a minute.

> **Good to know**
>
> Just want to look around first? An administrator can load a fully cabled example with **Load demo tenant** under **Administration → Tenants**. You can delete it afterwards.

## 1. Choose the tenant

Sign in (see [Signing in](https://docs.racktrace.io/signing-in)) and pick the tenant you want to work in with the **Tenant** picker at the top. A tenant is one customer, or your own organisation. No tenant yet? An administrator creates one under **Administration → Tenants** with **New tenant**.

## 2. Create a site

1. On the dashboard, click **New site**.
2. Fill in **ID** `HQ` and **Name** `Headquarters`, and click **Create site**.

The ID is short on purpose: it becomes the start of every path, such as `HQ/00/SL/RK001`. See [IDs and paths](https://docs.racktrace.io/concepts/structure#ids).

## 3. Add a floor

On the site page, click **New floor**, fill in **ID** `00` and **Name** `Ground floor`, and click **Create floor**.

## 4. Add a server room and an office

1. On the site page, click **Room** in the block of floor 00.
2. Create the server room: **ID** `SL`, **Name** `Server room`.
3. Click **Room** once more and create the office: **ID** `LA`, **Name** `Office area`.

## 5. Add a rack

Open the server room and click **New rack**. Fill in **ID** `RK001`, **Name** `Main rack` and **Height (U)** `42`, and click **Create rack**.

## 6. Fill the rack

Click the rack to open it in the [rack editor](https://docs.racktrace.io/features/rack-editor).

1. In the **Devices** panel on the left, choose **Generic** in the list of manufacturers.
2. Drag **Patch Panel 24x RJ45 Cat6** onto the top rack unit.
3. Drag **Switch 24x GbE + 4x SFP+** onto the unit below it.

Each device gets an ID straight away (such as `PP01` and `SW01`), and the cursor jumps to its **Name** field, so you can type a name. Everything is saved as you go.

![The rack editor with a patch panel and a switch](https://docs.racktrace.io/assets/screens/rack-editor.webp "The rack editor: the device templates on the left, the rack in the middle, the inspector on the right.")

## 7. Add a floor box in the office

Open the office (room `LA`) and click **Add device**. Choose the **Template** **Floor Box 2x RJ45**, leave **ID** empty for an automatic one, and click **Add device**.

## 8. Cable the floor box to the patch panel

This is the permanent cabling in the building: from the rear of the patch panel to the floor box.

1. Go back to the rack editor and click the patch panel.
2. In the inspector, choose **Tools → Manage building connections**.
3. Set **Number of connections** to `2` and choose the **Target room** `LA`. The floor box is ticked under **Target devices**.
4. Check the **Preview** and click **Create connections**.

## 9. Patch the panel to the switch

In the rack editor, click port 01 of the patch panel and then port 01 of the switch. A patch cable appears between them, in its colour. To connect a whole range at once, use **Tools → Bulk connect…** (see [Bulk connect](https://docs.racktrace.io/features/cables-and-tracing#bulk-connect)).

## 10. Connect a PC and trace the cable

1. In the office, click **Add device**, choose the **Template** **Workstation** and click **Add device**.
2. On the device page of the PC, click its port and then **Connect cable**. Choose the floor box, then port 01, and click **Connect**.
3. Click **Trace** on the same port.

The trace shows the whole path: from the PC, through the floor box and the patch panel, to the switch. See [Tracing a cable end to end](https://docs.racktrace.io/features/cables-and-tracing#tracing).

![A trace from a PC through a floor box and a patch panel to the switch](https://docs.racktrace.io/assets/screens/trace.webp "A trace follows the cable through every patch panel and outlet on the way.")

## Next steps

- Put the drawing of the floor in RackTrace and place the rack and the floor box on it: [Floor plans](https://docs.racktrace.io/features/floor-plans).
- Print cable labels and a QR sticker for the rack: [Labels and QR codes](https://docs.racktrace.io/features/labels).
- Document the VLANs and give the switch ports a profile: [Network plan](https://docs.racktrace.io/network/network-plan).
- Invite your colleagues: [Users, groups and rights](https://docs.racktrace.io/administration/users-and-groups).
