Source and freshness
On this page
RackTrace keeps four kinds of knowledge apart, and every observation says where it comes from and how old it is. So you can always tell what someone entered, what a source saw, what is still to be built and what the simulation computed.
The four states#
| Label | What it means |
|---|---|
| Documented | Entered in RackTrace: by a person, an import, or a discovery sync you reviewed. This is the documentation. |
| Observed | Reported by a discovery source (UniFi, Meraki, FortiGate, the scanner, a JSON source, Auvik), with the source and the age of its last report: Observed 12 min ago · UniFi. |
| Planned | Intended, not built yet — a planned cable, for example. |
| Simulated | Computed by the simulation from the documentation and the sources: decision support, not a measurement. |
You find the labels at the top of a device page (Documented and one Observed label per discovery source of the device), next to a planned cable in its ports, in the sources strip on the Discovery page, in All tenants and above a simulation result. Hover over an Observed label to see the source, when the source observed it, when RackTrace received it and when it counts as old.
Fresh, old and unknown#
An observation is one of three:
- Fresh (green) — the source's last report is younger than the threshold of its kind.
- Old (amber, striped: Observed 7 h ago — old) — the report is older than the threshold. It says what was true then, not now: a port it reported down gets a dashed ring and counts as unknown, and the online or offline dot of the device turns grey. All tenants lists the source as a notice.
- Unknown (grey: Not observed yet) — the source never reported anything. That is not old (there is no data to be old) and not down or off.
Unknown is not down
A silent scanner, a source that never synced, a wrong configuration and a device that has failed stay different things. Only a fresh report that a link or device is down counts as down.
Thresholds per kind of source#
| Kind of source | Sources | Old after |
|---|---|---|
| Controller API | UniFi (Site Manager), Meraki (Dashboard API), FortiGate (REST API), NetBird | 6 hours |
| Scanner (SNMP) | The RackTrace agent | 6 hours |
| JSON push | A script or system that pushes the open JSON format | 6 hours |
| Import from another system | Auvik, JSON pull (URL) | 6 hours |
| Monitoring check | Every check | 3 of its intervals (each at least a minute): then the check is unknown |
The same threshold applies everywhere: on the device page, in the simulation and in All tenants one source is fresh or old in all three.
A source with a longer refresh interval (up to 1440 minutes) than its threshold, or one that is only read by hand (interval 0), shows as old between two syncs. That is how old its data really is; the threshold stays that of its kind. The tooltip of the label shows the refresh interval next to the threshold.
Observation time and receipt time#
Every report has two times: when the source observed it and when RackTrace received it. A pull source (UniFi, Meraki, FortiGate, Auvik, a JSON URL) observes at the start of the read. A push (the scanner, a JSON push) may send its own time: observed_at per scope or for the whole push, or the start time of a scan. The observation time counts for the freshness, as long as it is no more than 5 minutes after the receipt and no more than 24 hours before it — the same window as for monitoring measurements. A JSON push with a time outside that window is refused with a message that says why (check the clock of the sender); a scan whose start time is outside it gets a note on the source and counts from its receipt, as does a push without a time.
So a report observed 10 minutes ago and received now is 10 min old, and the tooltip shows both times.