Onboarding a tenant
Onboarding shows what a new tenant still needs before it is usable: the steps, how far each one is, and a list of what is missing. RackTrace works it all out from the documentation and from what discovery sees — there is nothing to tick off. Open it from the menu (Network → Onboarding) or from the card on the dashboard.
The steps#
| Step | Required | Done when |
|---|---|---|
| Location | yes | The tenant has a site with a room. |
| Discovery source | yes | A UniFi site, Meraki network, FortiGate, scanner or JSON source is linked to the tenant. |
| First discovery | yes | The source synced and saw network devices. |
| Core devices linked | yes | Every switch, router, gateway, firewall and access point discovery sees is linked to a documented device. |
| Uplinks cabled | yes | Every uplink port of a linked device has a documented cable. |
| VLANs documented | yes | Every VLAN in the network configuration a source reports is in the network plan. |
| Racks | no | Every documented switch, router, gateway and firewall is in a rack. |
| Monitoring and notifications | no | Monitoring is on, something is monitored, and a notification policy that is switched on mails when an alert opens. |
A step can also say Cannot be checked: the sources do not report what it needs — no uplinks, or no network configuration. That is not the same as missing; it does not hold the tenant back.
When every required step is done, the page becomes Documentation health: the same overview, for when the network changes later.
Core devices linked#
The bar at the top shows which part of the core devices is linked, with the goal of 80% marked on it. Core devices are the switches, routers, gateways, firewalls and access points discovery sees.
- A device reported by two sources (the same MAC address, or linked to the same documented device) counts once.
- A device you ignore under Discovery, or that the source no longer reports, does not count.
- Servers, NAS devices and other infrastructure do not count.
What is missing#
Per kind, with a button on every line:
- Core devices not linked — Link opens Discovery on the devices that are not linked.
- Uplinks without a documented cable — with the neighbour discovery sees on the other end (LLDP). Connect cable opens the device. A cable that is only planned does not count: it is not there yet.
- VLANs seen but not documented — the networks a source configures that are not in the network plan: the same list as the review in the network plan, where Review takes you to take them over. A VLAN that is only seen on a port (the native VLAN 1 that most switches report on every port, for example) does not count.
- VLANs documented but not seen — in the plan, but no source configures them: perhaps they are no longer in use. The review proposes to remove them; they do not hold the step back.
- Network devices without a rack — access points are left out: they hang on a wall or a ceiling.
A list shows at most 100 lines, with the total next to its title.
Discovery sources#
Per linked source the last sync, how many network devices and clients it sees, and how fresh its last report is, with the label of the device page: Observed … ago while fresh, old once it is older than the threshold of its kind of source (6 hours, see Source and freshness) — what it says may no longer be true — and Not observed yet when it never reported. This used to be 24 hours on this page; it is now the same threshold everywhere. sync failed shows the error of the last sync.
Who sees what#
Everyone with access to the tenant sees its onboarding. The buttons open the pages where the work is done, and those pages ask for the usual rights: linking a source is for administrators, linking devices and cabling need the right to change the documentation, VLANs the right to change the network plan, notification policies the right to change monitoring.