Onboarding shows what a new tenant still needs before it is usable: the steps, how far each one is, and a list of what is missing. RackTrace works it all out from the documentation and from what discovery sees — there is nothing to tick off. Open it from the menu (Network → Onboarding) or from the card on the dashboard.

The steps#

StepRequiredDone when
LocationyesThe tenant has a site with a room.
Discovery sourceyesA UniFi site, Meraki network, FortiGate, scanner or JSON source is linked to the tenant.
First discoveryyesThe source synced and saw network devices.
Core devices linkedyesEvery switch, router, gateway, firewall and access point discovery sees is linked to a documented device.
Uplinks cabledyesEvery uplink port of a linked device has a documented cable.
VLANs documentedyesEvery VLAN in the network configuration a source reports is in the network plan.
RacksnoEvery documented switch, router, gateway and firewall is in a rack.
Monitoring and notificationsnoMonitoring is on, something is monitored, and a notification policy that is switched on mails when an alert opens.

A step can also say Cannot be checked: the sources do not report what it needs — no uplinks, or no network configuration. That is not the same as missing; it does not hold the tenant back.

When every required step is done, the page becomes Documentation health: the same overview, for when the network changes later.

Core devices linked#

The bar at the top shows which part of the core devices is linked, with the goal of 80% marked on it. Core devices are the switches, routers, gateways, firewalls and access points discovery sees.

  • A device reported by two sources (the same MAC address, or linked to the same documented device) counts once.
  • A device you ignore under Discovery, or that the source no longer reports, does not count.
  • Servers, NAS devices and other infrastructure do not count.

What is missing#

Per kind, with a button on every line:

  • Core devices not linked — Link opens Discovery on the devices that are not linked.
  • Uplinks without a documented cable — with the neighbour discovery sees on the other end (LLDP). Connect cable opens the device. A cable that is only planned does not count: it is not there yet.
  • VLANs seen but not documented — the networks a source configures that are not in the network plan: the same list as the review in the network plan, where Review takes you to take them over. A VLAN that is only seen on a port (the native VLAN 1 that most switches report on every port, for example) does not count.
  • VLANs documented but not seen — in the plan, but no source configures them: perhaps they are no longer in use. The review proposes to remove them; they do not hold the step back.
  • Network devices without a rack — access points are left out: they hang on a wall or a ceiling.

A list shows at most 100 lines, with the total next to its title.

Discovery sources#

Per linked source the last sync, how many network devices and clients it sees, and how fresh its last report is, with the label of the device page: Observed … ago while fresh, old once it is older than the threshold of its kind of source (6 hours, see Source and freshness) — what it says may no longer be true — and Not observed yet when it never reported. This used to be 24 hours on this page; it is now the same threshold everywhere. sync failed shows the error of the last sync.

Who sees what#

Everyone with access to the tenant sees its onboarding. The buttons open the pages where the work is done, and those pages ask for the usual rights: linking a source is for administrators, linking devices and cabling need the right to change the documentation, VLANs the right to change the network plan, notification policies the right to change monitoring.