Rack cabinets and the picture of a rack
On this page
A rack can be a real cabinet: a Rittal VX IT, an APC NetShelter SX, a wall-mounted FlatBox and so on. RackTrace then knows its size, colour and doors, and draws the rack as that cabinet — with everything that is mounted in it — so you and your customer see how it will look.
Choosing the cabinet of a rack#
- Open the rack in the rack editor. With nothing selected, the inspector shows the rack's settings.
- Choose the Cabinet model. The models are grouped by maker and series; the article number is behind the name.
- The rack takes the height of the model (for example 42U). When a device sits higher than the new model allows, you get a message and nothing changes.
You can also choose the model when you create a rack (New rack on the room page) or with Edit on the rack. None — a plain 19" rack takes the model off again; the height stays.
The model shows in several places:
- the rack editor draws the frame in the colour of the cabinet and names the model next to FRONT / BACK;
- the floor plan draws the rack at the real width and depth of the cabinet (without a model: 0.6 × 1 m);
- the room page names the model under each rack;
- the picture of the rack and the report draw the real cabinet.
Changing the model can be undone (Ctrl+Z) and is in the history of the rack.
Working in the realistic view#
In the rack editor, Diagram / Realistic in the toolbar switches between the diagram you patch in and the rack as the real cabinet with the equipment in it. Your browser remembers the choice.
In the realistic view you work as in the diagram:
- click a device to select it and see it in the inspector;
- click a port, then a second port, to connect them — or drag from port to port; hover a port to see where it goes;
- click a free rack unit to add a device there, or drag a device from the panel on the left onto a unit;
- Front / Back, zoom, moving around and the rack picker work as always; Door shuts the door of the cabinet (devices can still be clicked through it), Bezels and Cables show or hide the bezels and the patch cords.
The cables are drawn as a tidy installer would run them. Every cable is its own cord in its cable colour, from its port to the port it is connected to:
- a patch cord to a device right above or below (a patch panel and its switch, with at most a cable manager or two units in between) goes straight there, one next to the other, without crossing;
- cables over a longer distance go sideways into the side room of the cabinet, run there as a bundle along the mounting angle — tied every few units — and come out again at the port they end on; a cable to a 0U PDU runs to the PDU in the side room;
- cables that leave the rack are bundled and go up through the roof; above a single rack you see where they go and how many (
↑ HQ/00/LA 4×); - a cable whose other end is on the other side of the cabinet, or on a device seen from behind, is drawn fainter;
- a cable manager with a cover hides the cords that run in it: you see them go in at the top and come out at the bottom, the rest runs behind the cover. Click the cover to select the cable manager.
Click a port or a device to light up its cables; the other cables fade. A cover with one of those cables behind it turns see-through, so you can follow the cable.
The cable managers with a cover are Cable Manager 1U with Cover and Cable Manager 2U with Cover in the device library (under Cable manager); an open one (Cable Manager 1U) shows its fingers and the cords in it. A template of your own counts as one with a cover when its model says so (cover, deksel).
In the row view the racks stand against each other as in the room, with a cable tray above them. The cables between two racks come out of the roof of the one, run tied together through the tray and go down into the other. Cables to a rack elsewhere run to the end of the tray, with where they go and how many (→ HQ/01/TR/RK101 · 2×).
Moving a device by dragging, the cable routes and the VLAN, network, live and simulation colours are in the diagram.
The picture: how it will look#
Click Picture in the toolbar of the rack editor, or Picture — as it will look in the inspector. In the row view and with Picture on the room page you get all racks of the room side by side, standing on the same floor, as they stand in the room — with the cable tray and the cables between them.
The picture is the same drawing, to show or download. It is drawn to scale: the cabinet with its frame, plinth or castors, the 19" mounting angles with their unit numbers, and every device with its real front — drive bays, displays, fans, the ports where they sit on the device and the patch cords in their cable colour. A device mounted on the other side is seen deeper in the cabinet, darker. On the back, 0U PDUs stand upright in the side room of the cabinet.
| Option | What it does |
|---|---|
| Front / Back | Which side of the racks you see. |
| Door closed | Shows the front or rear door shut: the equipment shows through the perforation or the glass. |
| Patch cords | The plugs of the connected cables in their colour. |
| ID labels | The ID of each device on a label at its mounting ear. |
| Unit numbers | The unit numbers next to the mounting angles. |
Click the picture to see it at full size; click again to fit it. SVG downloads the drawing (sharp at any size, for a quote or a presentation), PNG a picture of it. A rack without a cabinet model is drawn as a plain black 600 mm cabinet; the picture tells you which ones.
Tip
Plan the rack before it is built: place the devices with status planned in the rack editor and send the customer the picture. Planned devices have a dashed blue outline.
The cabinets in the library#
Open Library & reports → Device library → Rack cabinets. The built-in library has 150+ cabinets from the makers' data sheets:
- Rittal: VX IT (42U and 47U, 600 and 800 wide, vented or glazed, also the pre-configured ones with plinth), the older TS IT, FlatBox, AX IT and AX / EL wall-mounted enclosures, DK Data Rack open frames;
- APC: NetShelter SX and SX Gen 2 (24U to 52U, also the white ones), NetShelter SV, Easy Rack, NetShelter WX wall-mounted cabinets and the open frames;
- Triton, Minkels, Lande, Eaton, Vertiv, Conteg, HPE, Digitus and Panduit: their most common cabinets.
Filter by maker or kind, or search: every word must match, for example vx it 800, 42u 1200 or ar3150. Click a cabinet to see it with its door open and shut, its size, colour, doors and load, and a link to its data sheet. Cabinets that are no longer sold say so in their notes, with their successor.
New cabinet (or Duplicate on one that is close) adds your own, for all tenants (administrators) or for one tenant: manufacturer, model, article number, height in U and outside size in mm, colour, front and rear door, perforation, handle, plinth or feet, and the name on the cabinet. The drawing next to the form follows what you fill in. Changing the height of a cabinet changes the racks of that model too.
Removing a built-in cabinet hides it from the library; racks that are that model keep it. Deleting your own cabinet makes its racks plain 19" racks of the same height. Administrators bring removed or edited built-in cabinets back with ↺ on the Device templates tab.